Kosmos Guidance Performance Evaluation Data Annotation
An observational study of Heart and Ultrasound, run by EchoNous Inc. at 1 site in United States.
Trial summary
The purpose of this study is to supplement prior Kosmos Trio Guidance performance testing conducted under ECHO-020 Kosmos Guidance, Grading, and Capture Performance Evaluation Protocol. Read more about this study
- Who is it for?
- Ages 18 to 80 yearsHealthy volunteers can take part
- Conditions the study is for
- Heart, Ultrasound, Cardiac Ultrasound
- What is being tested?
- Category 1: Corrective Guidance, Category 2: Incorrect Scanning Window and Category 3: Incorrect Probe Orientation
- Type of treatment
- Medical device
- How many people
- 81 participants
- Where
- 1 siteUnited States
- Study dates
- 5 Jun 2026to 30 Sep 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: The study used retrospective datasets from 2 sources: ECHO-020 Kosmos Guidance, Grading, and Capture Performance Evaluation study, and ECHO-025 Kosmos Guidance Performance Evaluation study. Both datasets comprise fully de-identified, retrospective, echocardiographic clips acquired using the Kosmos diagnostic ultrasound system. Data collection for both studies was performed at EchoNous headquarters in Redmond, Washington. Source data was collected targeting a balanced representation of demographics and clinical characteristics (including gender and BMI) to ensure the generalizability of study findings.
Who may be able to join
- All data used in this study must have been collected per 45 CFR § 26,
- Data must have been collected per source protocol requirements with no deviation for that data set,
- Adequate demographic information available from original study participation (sex, BMI, ethnicity, and race)
- Exam acquisition performed by a qualified echocardiographer using the Kosmos system
Who cannot join
- Inadequate demographic information corresponding to the available data, and
- Non-echocardiographer acquired images.
Trial locations and contacts
1 site in 1 country.
About this study
The purpose of this study is to supplement prior Kosmos Trio Guidance performance testing conducted under ECHO-020 Kosmos Guidance, Grading, and Capture Performance Evaluation Protocol. The Kosmos Trio Guidance algorithm is designed to provide guidance to help novice scanners acquire images and videos during ultrasound scanning of three cardiac views (Parastenal Long Axis, Apical 4 Chamber, and Apical 2 Chamber) with Kosmos Trio. The study will divide the guidance cues not evaluated sufficiently in the ECHO-020 study into four categories: 1) corrective guidance, 2) incorrect scanning window, 3) incorrect probe orientation, and 4) low confidence prediction. For each guidance cue evaluated in this study, expert annotators will review two clips: one suboptimal view, collected when the probe is positioned at an incorrect location; and one guided view, captured after the sonographer followed the probe motion cue displayed by the system. Annotators will review each pair of clips and respond indicating either i) Yes, the guided clip demonstrates the appropriate correction from the suboptimal view; ii) No, the guided clip does not demonstrate the appropriate correction from the suboptimal view; or iii) Unevaluable, the guided clip is technically inadequate for assessment. For each category of guidance cues, the outcome measure will be the rate at which annotators respond "Yes." Finally, this study will also evaluate the Kosmos Trio Auto-Capture algorithm's ability to detect and capture a diagnostic-quality image. Annotators will rate clips captured by Kosmos Trio Auto-Capture on an ACEP-based image quality scale. The outcome measure will be the image quality score. The study design involves the compilation of de-identified retrospective cardiac clips acquired using the Kosmos diagnostic ultrasound system. This data was collected for two previous studies; no additional data will be collected from previous study participants for the purposes of this study.
- Conditions
- Heart, Ultrasound, Cardiac Ultrasound, Cardiac Disease
- Being tested
- Category 1: Corrective Guidance, Category 2: Incorrect Scanning Window, Category 3: Incorrect Probe Orientation, Category 4: Low Confidence Prediction, Auto-Capture Frame-Level Re-Annotation
- Medical subject headings
- Heart Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Category 1: Corrective GuidanceDevice
When the system detects that the probe is near the correct cardiac window but requires a specific directional adjustment, it displays a Category 1 - Corrective Guidance message. Each case in this project consists of two clips: Clip A - Suboptimal View: captured after the sonographer has intentionally moved the probe to a prescribed off-target position; and Clip B - Guided View: captured after the sonographer followed the Category 1 probe motion cue displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 1 corrective guidance instruction produces a discernible improvement in overall image quality. They will provide an answer of Yes, No, or Unevaluable.
Category 2: Incorrect Scanning WindowDevice
When the system detects that the probe is positioned at a fundamentally incorrect anatomical location relative to the target cardiac view, it displays a Category 2 - Incorrect Scanning Window message. Each case in this project consists of two clips: Clip A - Suboptimal View: captured after the sonographer has intentionally a clearly incorrect anatomical location; and Clip B - Guided View: captured after the sonographer followed the Category 2 window-navigation cue and moved to the correct scanning window displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 2 guidance instruction produces a clip in the correct scanning window. They will provide an answer of Yes, No, or Unevaluable.
Category 3: Incorrect Probe OrientationDevice
When the system detects that the probe has been rotated 180° around its longitudinal axis, producing a laterally mirrored image, it displays a Category 3 - Incorrect Probe Orientation message. Each case in this project consists of two clips: Clip A - Suboptimal View: with the probe rotated 180° at the correct cardiac window, producing a mirrored image; and Clip B - Guided View: sonographer corrected the probe orientation in response to the Category 3 message displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 3 guidance instruction produced a clip that is oriented correctly. They will provide an answer of Yes, No, or Unevaluable.
Category 4: Low Confidence PredictionDevice
When the system's confidence in the current image is insufficient to issue a specific directional correction, it displays a Category 4 - Low Confidence Prediction message. Each case in this project consists of two clips: Clip A - Suboptimal View: with the probe rotated 180° at the correct cardiac window, producing a mirrored image; and Clip B - Guided View: sonographer corrected the probe orientation in response to the Category 3 message displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 3 guidance instruction produced a clip that is oriented correctly. They will provide an answer of Yes, No, or Unevaluable.
Auto-Capture Frame-Level Re-AnnotationDevice
The Kosmos Trio Auto-Capture feature automatically triggers clip recording when it detects that a diagnostic quality image has been achieved. Each case in this project is a single captured clip. No comparison clip is provided. The view (PLAX, A4C, or A2C) is indicated for each case. For each frame in this clip, annotators will be asked to assign a quality grade using the ACEP 1-5 image quality scale (where 1 represents a frame in which the relevant anatomy is not visualized or identifiable, and 5 represents a frame in which the image is sharp and the relevant anatomy is well visualized and present in the frame) to each frame.
| Study group | Role | What they receive |
|---|---|---|
| Project 1 | Participants included in Project 1, Category 1: Corrective Guidance Receives: Device: Category 1: Corrective Guidance | |
| Project 2 | Participants included in Project 2, Category 2: Incorrect Scanning Window Receives: Device: Category 2: Incorrect Scanning Window | |
| Project 3 | Participants included in Project 3, Category 3: Incorrect Probe Orientation Receives: Device: Category 3: Incorrect Probe Orientation | |
| Project 4 | Participants included in Project 4, Category 4: Low Confidence Prediction Receives: Device: Category 4: Low Confidence Prediction | |
| Project 5 | Participants included in Project 5, Auto-Capture Frame-Level Re-annotation Receives: Device: Auto-Capture Frame-Level Re-Annotation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Guidance Algorithm Accuracy
Guidance algorithm accuracy will be evaluated using Positive Predictive Value (PPV), a calculation that compares the diagnostic quality between the suboptimal view following an indicated probe movement and the guided view following the Guidance correction of the probe location. PPV will be calculated for each cardiac view included in this study (PLAX, A4C, and A2C), across all four Guidance categories. PPV is calculated by dividing the number of True Positives (the number of trial pairs in which the post-action clip demonstrates that following the guidance instruction produced the intended improvement for the applicable guidance category) by the number of True Positives plus the number of False Positives (the number of trial pairs in which the post-action clip does not demonstrate the expected improvement for the applicable category). Success is defined as a PPV > 0.80 and 95% CI lower bound > 0.80 for each view. All three views must independently satisfy this criteria.
Measured: Post data acquisition (2 months)
Performance of Auto-Capture
The accuracy of Auto-Capture will be evaluated using Positive Predictive Value (PPV), a calculation that provides the proportion of clips captured using Auto-Capture that contain a sufficient proportion of diagnostic-quality frames to be considered clinically acceptable. PPV is calculated by dividing the number of True Positives (the number of clips with at least one full cardiac cycle of frames is determined to be diagnostic by expert reviewers, in accordance with the ACEP-based grading scale) by the number of True Positives plus the number of False Positives (the number of clips that do not have at least one full cardiac cycle of frames is determined to be diagnostic by expert reviewers, in accordance with the ACEP-based grading scale). Success is defined as a PPV > 0.80 and 95% CI lower bound > 0.80.
Measured: Post data acquisition (2 months)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted18 Aug 2026
- Study start5 Jun 2026
- Primary completion30 Aug 2026 (estimated)
- Study completion30 Sep 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for HeartStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Retrospective
- Enrolment
- 81 participants (estimated)
Sponsor and investigators
- Lead sponsor
- EchoNous Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07771270
- Sponsor's protocol ID
- ECHO-302
- Status last verified
- Aug 2026
- First submitted
- 13 Aug 2026
- Last updated
- 18 Aug 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Undecided: Publication decisions will be made at a later date.
Study at a glance
From the registry record, last updated by the sponsor on 18 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Kosmos Guidance Performance Evaluation Data Annotation
- ClinicalTrials.gov ID
- NCT07771270
- Acronym / sponsor ID
- ECHO-302
- Conditions
- Heart, Ultrasound, Cardiac Ultrasound, Cardiac Disease
- Study type
- Observational
- Recruitment status
- Active, not recruiting
- Enrolment
- 81 participants (estimated)
- Lead sponsor
- EchoNous Inc.Industry (pharma, biotech, devices)
- Study start
- 5 Jun 2026 (actual)
- Primary completion
- 30 Aug 2026 (estimated)
- Study completion
- 30 Sep 2026 (estimated)
- First posted
- 18 Aug 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to supplement prior Kosmos Trio Guidance performance testing conducted under ECHO-020 Kosmos Guidance, Grading, and Capture Performance Evaluation Protocol. The Kosmos Trio Guidance algorithm is designed to provide guidance to help novice scanners acquire images and videos during ultrasound scanning of three cardiac views (Parastenal Long Axis, Apical 4 Chamber, and Apical 2 Chamber) with Kosmos Trio. The study will divide the guidance cues not evaluated sufficiently in the ECHO-020 study into four categories: 1) corrective guidance, 2) incorrect scanning window, 3) incorrect probe orientation, and 4) low confidence prediction. For each guidance cue evaluated in this study, expert annotators will review two clips: one suboptimal view, collected when the probe is positioned at an incorrect location; and one guided view, captured after the sonographer followed the probe motion cue displayed by the system. Annotators will review each pair of clips and respond indicating either i) Yes, the guided clip demonstrates the appropriate correction from the suboptimal view; ii) No, the guided clip does not demonstrate the appropriate correction from the suboptimal view; or iii) Unevaluable, the guided clip is technically inadequate for assessment. For each category of guidance cues, the outcome measure will be the rate at which annotators respond "Yes." Finally, this study will also evaluate the Kosmos Trio Auto-Capture algorithm's ability to detect and capture a diagnostic-quality image. Annotators will rate clips captured by Kosmos Trio Auto-Capture on an ACEP-based image quality scale. The outcome measure will be the image quality score. The study design involves the compilation of de-identified retrospective cardiac clips acquired using the Kosmos diagnostic ultrasound system. This data was collected for two previous studies; no additional data will be collected from previous study participants for the purposes of this study.
Study design
- Observational model
- Case only
- Time perspective
- Retrospective
- Number of arms
- 5
| Arm | Type | Receives |
|---|---|---|
| Project 1 | – | Device: Category 1: Corrective GuidanceParticipants included in Project 1, Category 1: Corrective Guidance |
| Project 2 | – | Device: Category 2: Incorrect Scanning WindowParticipants included in Project 2, Category 2: Incorrect Scanning Window |
| Project 3 | – | Device: Category 3: Incorrect Probe OrientationParticipants included in Project 3, Category 3: Incorrect Probe Orientation |
| Project 4 | – | Device: Category 4: Low Confidence PredictionParticipants included in Project 4, Category 4: Low Confidence Prediction |
| Project 5 | – | Device: Auto-Capture Frame-Level Re-AnnotationParticipants included in Project 5, Auto-Capture Frame-Level Re-annotation |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- The study used retrospective datasets from 2 sources: ECHO-020 Kosmos Guidance, Grading, and Capture Performance Evaluation study, and ECHO-025 Kosmos Guidance Performance Evaluation study. Both datasets comprise fully de-identified, retrospective, echocardiographic clips acquired using the Kosmos diagnostic ultrasound system. Data collection for both studies was performed at EchoNous headquarters in Redmond, Washington. Source data was collected targeting a balanced representation of demographics and clinical characteristics (including gender and BMI) to ensure the generalizability of study findings.
Key inclusion criteria (4 listed)
- All data used in this study must have been collected per 45 CFR § 26,
- Data must have been collected per source protocol requirements with no deviation for that data set,
- Adequate demographic information available from original study participation (sex, BMI, ethnicity, and race)
- Exam acquisition performed by a qualified echocardiographer using the Kosmos system
Key exclusion criteria (2 listed)
- Inadequate demographic information corresponding to the available data, and
- Non-echocardiographer acquired images.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Category 1: Corrective GuidanceWhen the system detects that the probe is near the correct cardiac window but requires a specific directional adjustment, it displays a Category 1 - Corrective Guidance message. Each case in this project consists of two clips: Clip A - Suboptimal View: captured after the sonographer has intentionally moved the probe to a prescribed off-target position; and Clip B - Guided View: captured after the sonographer followed the Category 1 probe motion cue displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 1 corrective guidance instruction produces a discernible improvement in overall image quality. They will provide an answer of Yes, No, or Unevaluable. | Device | Project 1 |
| Category 2: Incorrect Scanning WindowWhen the system detects that the probe is positioned at a fundamentally incorrect anatomical location relative to the target cardiac view, it displays a Category 2 - Incorrect Scanning Window message. Each case in this project consists of two clips: Clip A - Suboptimal View: captured after the sonographer has intentionally a clearly incorrect anatomical location; and Clip B - Guided View: captured after the sonographer followed the Category 2 window-navigation cue and moved to the correct scanning window displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 2 guidance instruction produces a clip in the correct scanning window. They will provide an answer of Yes, No, or Unevaluable. | Device | Project 2 |
| Category 3: Incorrect Probe OrientationWhen the system detects that the probe has been rotated 180° around its longitudinal axis, producing a laterally mirrored image, it displays a Category 3 - Incorrect Probe Orientation message. Each case in this project consists of two clips: Clip A - Suboptimal View: with the probe rotated 180° at the correct cardiac window, producing a mirrored image; and Clip B - Guided View: sonographer corrected the probe orientation in response to the Category 3 message displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 3 guidance instruction produced a clip that is oriented correctly. They will provide an answer of Yes, No, or Unevaluable. | Device | Project 3 |
| Category 4: Low Confidence PredictionWhen the system's confidence in the current image is insufficient to issue a specific directional correction, it displays a Category 4 - Low Confidence Prediction message. Each case in this project consists of two clips: Clip A - Suboptimal View: with the probe rotated 180° at the correct cardiac window, producing a mirrored image; and Clip B - Guided View: sonographer corrected the probe orientation in response to the Category 3 message displayed by the system. For each pair of clips, annotators will be asked when Comparing Clip A and Clip B whether following the Category 3 guidance instruction produced a clip that is oriented correctly. They will provide an answer of Yes, No, or Unevaluable. | Device | Project 4 |
| Auto-Capture Frame-Level Re-AnnotationThe Kosmos Trio Auto-Capture feature automatically triggers clip recording when it detects that a diagnostic quality image has been achieved. Each case in this project is a single captured clip. No comparison clip is provided. The view (PLAX, A4C, or A2C) is indicated for each case. For each frame in this clip, annotators will be asked to assign a quality grade using the ACEP 1-5 image quality scale (where 1 represents a frame in which the relevant anatomy is not visualized or identifiable, and 5 represents a frame in which the image is sharp and the relevant anatomy is well visualized and present in the frame) to each frame. | Device | Project 5 |
Primary outcome
Guidance Algorithm Accuracy
Time frame: Post data acquisition (2 months)
Guidance algorithm accuracy will be evaluated using Positive Predictive Value (PPV), a calculation that compares the diagnostic quality between the suboptimal view following an indicated probe movement and the guided view following the Guidance correction of the probe location. PPV will be calculated for each cardiac view included in this study (PLAX, A4C, and A2C), across all four Guidance categories. PPV is calculated by dividing the number of True Positives (the number of trial pairs in which the post-action clip demonstrates that following the guidance instruction produced the intended improvement for the applicable guidance category) by the number of True Positives plus the number of False Positives (the number of trial pairs in which the post-action clip does not demonstrate the expected improvement for the applicable category). Success is defined as a PPV > 0.80 and 95% CI lower bound > 0.80 for each view. All three views must independently satisfy this criteria.
Performance of Auto-Capture
Time frame: Post data acquisition (2 months)
The accuracy of Auto-Capture will be evaluated using Positive Predictive Value (PPV), a calculation that provides the proportion of clips captured using Auto-Capture that contain a sufficient proportion of diagnostic-quality frames to be considered clinically acceptable. PPV is calculated by dividing the number of True Positives (the number of clips with at least one full cardiac cycle of frames is determined to be diagnostic by expert reviewers, in accordance with the ACEP-based grading scale) by the number of True Positives plus the number of False Positives (the number of clips that do not have at least one full cardiac cycle of frames is determined to be diagnostic by expert reviewers, in accordance with the ACEP-based grading scale). Success is defined as a PPV > 0.80 and 95% CI lower bound > 0.80.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Aug 2026.
- Individual participant dataSharing planned: Undecided. Publication decisions will be made at a later date.
Related trials for Heart
Enrolling by invitationObservational study
Multi-Scale Analysis of Phenotypes in Heart Failure (MAP-HEART)
Heart Failure
Not yet recruiting
Effects of Adding Vagal Neuromodulation to Manual Therapy in Women With Fibromyalgia
Fibromyalgia (FM) OR Fibromyalgia Syndrome, Manuel Therapy
Active, not recruitingObservational study
REdo Transcatheter Aortic VALVE Implantation for the Management of Transcatheter Aortic Valve Failure
Aortic Valve Stenosis
Not yet recruitingPhase 1/2
EDIT-401 in Adults Who Require Additional Lowering of Low-Density Lipoprotein Cholesterol (LDL-C)
Heterozygous Familial Hypercholesterolemia (HeFH)
RecruitingObservational study
Natural History of Noncirrhotic Portal Hypertension
Cystic Fibrosis, Immunologic Deficiency Syndrome
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Heart and Ultrasound, run by EchoNous Inc. at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 18 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Guidance Algorithm Accuracy (time frame: Post data acquisition (2 months)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Aug 2026.