HealthyNCT07781618
3D Foot Scanning and Customized 3D-Printed Foot Orthotics to Reduce Pressure on the Feet of Healthy Adults
A study testing Foot orthotics in people with Healthy, run by Universitaire Ziekenhuizen KU Leuven at 1 site in Belgium.
Trial summary
The number of people with diabetes mellitus worldwide is increasing rapidly and is expected to rise to 439 million by 2030, or 7.7% of the total adult world population. The complications that can arise as a result of chronic diabetes represent a major problem in terms of clinical treatment, socio-economic consequences… Read more about this study
- Who is it for?
- Ages 18 to 65 yearsHealthy volunteers can take part
- Conditions the study is for
- Healthy
- What is being tested?
- Foot orthotics
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 33 participants
- Where
- 1 siteBelgium
- Study dates
- 23 Oct 2023to 19 Aug 2026
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 65 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Reliability study:
The inclusion criteria:
- Healthy population, age 18-65-year-old
The exclusion criteria:
- No injury of trauma of the lower limb in the past 6 months
- No surgical procedures of the lower limbs or back in the past 6 months
- Not pregnant at the time of testing
- No (auto) immune system disorders with a possible impact on the feet (e.g., rheumatoid arthritis)
- No systemic or neurological disorder
Interventional study
The inclusion criteria:
- Healthy population, age 18-65-year-old
- Maximum weight of 90 kg
- In-shoe M2 - M3 or central pattern bilateral or left/right
The exclusion criteria:
- No injury of trauma of the lower limb in the past 6 months
- No surgical procedures of the lower limbs or back in the past 6 months
- Not pregnant at the time of testing
- No (auto) immune system disorders with a possible impact on the feet (e.g., rheumatoid arthritis)
- No systemic or neurological disorder
- Work does not require wearing safety shoes
Trial locations and contacts
1 site in 1 country.
About this study
Official title: 3D Surface Scanning for the Measurement of the Human Foot and Customized 3D Printed Foot Orthotics for Plantar Off-loading in Healthy Participants
The number of people with diabetes mellitus worldwide is increasing rapidly and is expected to rise to 439 million by 2030, or 7.7% of the total adult world population. The complications that can arise as a result of chronic diabetes represent a major problem in terms of clinical treatment, socio-economic consequences and costs to the health care system. One of the most serious complications is a diabetic foot, which is characterized by neuropathy, ischemia and limited joint mobility and makes the foot vulnerable to foot ulcers and possible amputation. Various interventions are being investigated to prevent foot ulcers, including custom-made foot orthotics (CFOs), also known as foot orthoses. The latter allows the health professional to achieve a number of functional effects, of which the redistribution of the plantar pressure load is the most valuable, especially in patients with so-called risk feet.
The use of integrated computer-aided design and computer-aided manufacturing systems to produce CFOs has become increasingly popular over the past decade. In practice, this digital workflow comprises three different phases. First the (3D) foot shape of the patient is recorded, then the arch support is designed using special software and finally the device is made using a subtractive or additive manufacturing process (3D printing). As a result, it can be concluded that the first two phases are decisive for determining the geometric characteristics of a CFO, while the last phase is more critical for selecting the material properties.
Read more
As for the first phase, digital approaches were developed, such as 3D optical scanning that allows the researcher to scan body parts directly, providing a robust base for determining a CFO's geometrical features. The anthropometric foot parameters examined were worth investigating, but exclusively zero-dimensional in nature, providing limited insight when assessing the 3D fit of a custom made foot orthotic. Thus, current knowledge in this area remains scarce and further efforts are needed to better understand the role of 'geometrical features' in dose-response characteristics of custom orthotics.
With regard to the production phase, additive manufacturing or 3D printing is gaining more and more attention and could potentially set a new standard for manufacturing CFOs. Limited research shows that 3D printed CFOs can be used to reduce plantar pressure in healthy and diabetic populations. However, it is important to mention that these studies have not fully exploited the possible complex design options that the additive manufacturing process can provide, as their designs are very similar to those used in less polyvalent subtractive manufacturing processes. In addition, the relief properties of previously described CFOs are not or rarely driven by patient-specific plantar pressure data.
Research design Prospective monocentric observational study with a healthy, asymptomatic population.
Objectives The main aim of this study is to evaluate the pressure distribution principle of custom orthotics in asymptomatic adults.
The study consists of two parts:
- Reliability study
- Observational study
Reliability study The methodological part of the current study consists of a reliability study with the focus on scanning the human foot. Since capturing the foot shape is the first step in the manufacturing process of custom insoles, it is important to use a reliable and objective scanning technique. This study aims to test the reliability, more specifically the intra-, inter-rater and test-retest reliability, of a portable, optical 3D scanner. In addition to the traditional zero-dimensional anthropometric measurements of the foot, mainly one-dimensional outcome measures will be studied.
Observational study In the observational part, the pressure distribution mechanism of several 3D-printed CFOs on the plantar pressure in asymptomatic patients with a so-called M2-M3 (metatarsal head of the second and third toe) pressure pattern at the level of the forefoot. There is a limited amount of literature on the effect of custom 3D-printed foot orthotics on plantar pressure distribution in healthy populations. In addition, the currently available literature appears to contain heterogeneous groups of participants with different plantar pressure distribution patterns, which complicates correct interpretation and generalization of the results, as the same orthosis designs are used for different pressure distribution patterns. During this study, several custom 3D-printed insoles, differentiated in padding density, structural architecture and geometric shape, will be applied to participants with M2-M3 forefoot patterns and then documented with a pressure distribution alg. Finally, a durability study will be conducted with the custom sole that provides the best relief from the peak pressure area of the forefoot.
- Conditions
- Healthy
- Being tested
- Foot orthotics
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Foot orthoticsOther
Foot orthotics
| Study group | Role | What they receive |
|---|---|---|
| Within-Participant Orthotic Comparison | Experimental | The study still has one experimental arm; the different orthoses are intervention conditions within that arm. It is a single-group, within-participant repeated-measures design. Receives: Other: Foot orthotics |
What is being measured
The primary outcome is the main question the study is designed to answer.
Effect of custom-made foot orthotics on plantar pressure in people with a M2-3 pressure pattern.
The main aim of this study is to evaluate the pressure distribution principle of custom orthotics in asymptomatic adults with a M2-3 pressure pattern.
Measured: From enrollment to the end of the of the test at 6 weeks.
Reliability of 3D scanning
To evaluate the inter-, intra-rater and test-retest reliability of 3D surface scanning for measuring and recording human foot shape in a non-weight bearing condition.
Measured: From enrollment to final scanning after 3 days.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted24 Aug 2026
- Study start23 Oct 2023
- Primary completion4 Jun 2026
- Study completion19 Aug 2026
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for HealthyStudies of the same condition, open and under way.
- More trials run by Universitaire Ziekenhuizen KU LeuvenThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Prospective monocentric observational study with a healthy, asymptomatic population.
- Masking
- None (open label)
- Enrolment
- 33 participants (actual)
Sponsor and investigators
- Lead sponsor
- Universitaire Ziekenhuizen KU Leuven
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07781618
- Sponsor's protocol ID
- S67786
- Status last verified
- Aug 2026
- First submitted
- 19 Aug 2026
- Last updated
- 24 Aug 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 24 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- 3D Surface Scanning for the Measurement of the Human Foot and Customized 3D Printed Foot Orthotics for Plantar Off-loading in Healthy Participants
- ClinicalTrials.gov ID
- NCT07781618
- Acronym / sponsor ID
- S67786
- Conditions
- Healthy
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 33 participants (actual)
- Lead sponsor
- Universitaire Ziekenhuizen KU LeuvenUniversity, hospital or other
- Study start
- 23 Oct 2023 (actual)
- Primary completion
- 4 Jun 2026 (actual)
- Study completion
- 19 Aug 2026 (actual)
- First posted
- 24 Aug 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The number of people with diabetes mellitus worldwide is increasing rapidly and is expected to rise to 439 million by 2030, or 7.7% of the total adult world population. The complications that can arise as a result of chronic diabetes represent a major problem in terms of clinical treatment, socio-economic consequences and costs to the health care system. One of the most serious complications is a diabetic foot, which is characterized by neuropathy, ischemia and limited joint mobility and makes the foot vulnerable to foot ulcers and possible amputation. Various interventions are being investigated to prevent foot ulcers, including custom-made foot orthotics (CFOs), also known as foot orthoses. The latter allows the health professional to achieve a number of functional effects, of which the redistribution of the plantar pressure load is the most valuable, especially in patients with so-called risk feet.
The use of integrated computer-aided design and computer-aided manufacturing systems to produce CFOs has become increasingly popular over the past decade. In practice, this digital workflow comprises three different phases. First the (3D) foot shape of the patient is recorded, then the arch support is designed using special software and finally the device is made using a subtractive or additive manufacturing process (3D printing). As a result, it can be concluded that the first two phases are decisive for determining the geometric characteristics of a CFO, while the last phase is more critical for selecting the material properties.
As for the first phase, digital approaches were developed, such as 3D optical scanning that allows the researcher to scan body parts directly, providing a robust base for determining a CFO's geometrical features. The anthropometric foot parameters examined were worth investigating, but exclusively zero-dimensional in nature, providing limited insight when assessing the 3D fit of a custom made foot orthotic. Thus, current knowledge in this area remains scarce and further efforts are needed to better understand the role of 'geometrical features' in dose-response characteristics of custom orthotics.
With regard to the production phase, additive manufacturing or 3D printing is gaining more and more attention and could potentially set a new standard for manufacturing CFOs. Limited research shows that 3D printed CFOs can be used to reduce plantar pressure in healthy and diabetic populations. However, it is important to mention that these studies have not fully exploited the possible complex design options that the additive manufacturing process can provide, as their designs are very similar to those used in less polyvalent subtractive manufacturing processes. In addition, the relief properties of previously described CFOs are not or rarely driven by patient-specific plantar pressure data.
Research design Prospective monocentric observational study with a healthy, asymptomatic population.
Objectives The main aim of this study is to evaluate the pressure distribution principle of custom orthotics in asymptomatic adults.
The study consists of two parts:
- Reliability study
- Observational study
Reliability study The methodological part of the current study consists of a reliability study with the focus on scanning the human foot. Since capturing the foot shape is the first step in the manufacturing process of custom insoles, it is important to use a reliable and objective scanning technique. This study aims to test the reliability, more specifically the intra-, inter-rater and test-retest reliability, of a portable, optical 3D scanner. In addition to the traditional zero-dimensional anthropometric measurements of the foot, mainly one-dimensional outcome measures will be studied.
Observational study In the observational part, the pressure distribution mechanism of several 3D-printed CFOs on the plantar pressure in asymptomatic patients with a so-called M2-M3 (metatarsal head of the second and third toe) pressure pattern at the level of the forefoot. There is a limited amount of literature on the effect of custom 3D-printed foot orthotics on plantar pressure distribution in healthy populations. In addition, the currently available literature appears to contain heterogeneous groups of participants with different plantar pressure distribution patterns, which complicates correct interpretation and generalization of the results, as the same orthosis designs are used for different pressure distribution patterns. During this study, several custom 3D-printed insoles, differentiated in padding density, structural architecture and geometric shape, will be applied to participants with M2-M3 forefoot patterns and then documented with a pressure distribution alg. Finally, a durability study will be conducted with the custom sole that provides the best relief from the peak pressure area of the forefoot.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Prospective monocentric observational study with a healthy, asymptomatic population.
| Arm | Type | Receives |
|---|---|---|
| Within-Participant Orthotic Comparison | Experimental | Other: Foot orthoticsThe study still has one experimental arm; the different orthoses are intervention conditions within that arm. It is a single-group, within-participant repeated-measures design. |
Who may qualify
- Ages
- 18 to 65 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Foot orthoticsFoot orthotics | Other | Within-Participant Orthotic Comparison |
Primary outcome
Effect of custom-made foot orthotics on plantar pressure in people with a M2-3 pressure pattern.
Time frame: From enrollment to the end of the of the test at 6 weeks.
The main aim of this study is to evaluate the pressure distribution principle of custom orthotics in asymptomatic adults with a M2-3 pressure pattern.
Reliability of 3D scanning
Time frame: From enrollment to final scanning after 3 days.
To evaluate the inter-, intra-rater and test-retest reliability of 3D surface scanning for measuring and recording human foot shape in a non-weight bearing condition.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Aug 2026.
- Individual participant dataSharing planned: Undecided
Related trials for Healthy
RecruitingPhase 3
A Study to Learn About the Safety of an Expanded Pneumococcal Vaccine in Healthy Infants
Pneumococcal Disease
RecruitingObservational study
Development of Magnetic Resonance Imaging Techniques for Studying Mood and Anxiety Disorders
Mood Disorders, Anxiety Disorders
Not yet recruiting
Positron Emission Tomography and Organ-Specific Changes in Participants Co-Enrolled in NIH Studies of Plasmodium Vivax Controlled Human Malaria Infection
Healthy Volunteer, Malaria
Not yet recruiting
Evaluating the Healthy Families PrEP Program for Women at Risk for HIV
HIV, Pregnancy
RecruitingPhase 1
A Single Ascending Dose Study of DTI-117 Given Intramuscularly in Healthy Participants.
Healthy Adult
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Foot orthotics in people with Healthy, run by Universitaire Ziekenhuizen KU Leuven at 1 site in Belgium.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 24 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Effect of custom-made foot orthotics on plantar pressure in people with a M2-3 pressure pattern. (time frame: From enrollment to the end of the of the test at 6 weeks.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Aug 2026.