AzTrials
AzTrials

Lower Limb Amputation Below KneeNCT07791433

Automatic Prosthetic Foot Stiffness Modulation to Improve Balance in the Real World

A study testing Fixed stiffness prosthesis and Automatic stiffness prosthesis in people with Lower Limb Amputation Below Knee, run by Seattle Institute for Biomedical and Clinical Research at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this clinical trial is to determine if automatic stiffness modulation improves balance control in ambulatory individuals with below-knee amputations in real-world conditions. Read more about this study

Who is it for?
Ages 18 to 79 years
Conditions the study is for
Lower Limb Amputation Below Knee
What is being tested?
Fixed stiffness prosthesis and Automatic stiffness prosthesis
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteUnited States
Study dates
Nov 2026to Nov 2028
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 79 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Unilateral transtibial (below-knee) amputation
  • Been fit with a prosthesis and used it for at least 6 months
  • Wear the prosthesis for 4 or more hours on average per day
  • Be at least one-year post-amputation
  • Able to walk on a treadmill

Who cannot join

  • Presence of disorder, pain, or injury other than amputation that interferes with gait
  • Current skin irritation or injury on residual limb
  • Use of an assistive device for walking (cane, walker, etc.)

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

United States1 site
  • VA Puget Sound Healthcare System

    Seattle, Washington, 98108

    Glenn K Klute, PhD, 206.277.6792, Glenn.Klute@va.gov

    Elise Campbell, 206.277.6792, Elise.Campbell@va.gov

Other trials in United States

About this study

Official title: Automatic Activity-Dependent and Phase-Varying Prosthetic Foot Stiffness Modulation to Improve Balance Control in Individuals With Lower-Limb Amputations in the Real World

The goal of this clinical trial is to determine if automatic stiffness modulation improves balance control in ambulatory individuals with below-knee amputations in real-world conditions. The main question this clinical trial will answer is:

  • Can a user-specific automatic stiffness prosthesis improve balance control compared to user's fixed stiffness prosthesis that was clinically prescribed?

Participants will perform free-ranging ambulatory activities outside the laboratory that include nine ambulatory activities of daily living (walking at different speeds, turning, ramp ascent/descent, while carrying a load, and while walking on uneven terrain) while wearing, in random order, 1) a fixed stiffness prosthesis that was clinically prescribed and 2) an automatic stiffness prosthesis that uses an open source ankle configured to implement a user- and activity-specific automatic stiffness modulation control scheme intended to improve balance control.

Read the detailed description

Individuals with lower limb amputations are at higher risk of falling compared to able-bodied and other clinical populations and are more likely to sustain life-altering injuries. The higher fall risk is primarily due to the loss of muscles crossing the ankle, which are critical to maintaining balance control. Prosthetic devices are designed to provide appropriate stiffness for needed stability and support. While research has shown the optimal stiffness to maintain balance varies across ambulatory activities (e.g., straight walking versus turning), most clinically prescribed prosthetic devices are passive and only provide a fixed stiffness level. The one commercially available, powered prosthetic ankle-foot, has not been shown to restore balance control. Thus, a prosthetic device that actively adjusts ankle stiffness across different ambulatory activities is critically needed to advance the field and improve balance control for those with lower-limb amputations. The goal of this clinical trial is to identify prosthesis stiffness that optimizes balance control in individuals with below knee amputations as they perform typical ambulatory activities of daily living. By matching the ankle stiffness to the task requirements, the investigators believe balance control will significantly improve and fall risk will decrease for those with lower-limb amputations.

Each participant will be fit with a novel prosthesis that includes a low-profile prosthetic foot whose stiffness category will be determined by their body weight and activity level (standard clinical practice), a prosthetic foot whose stiffness category is two categories stiffer, and another whose stiffness is two categories less stiff. Participants will continue to use their existing prosthetic socket and suspension system, but their pylon length will be adjusted as needed. While wearing the different study prostheses in randomized order, nine ambulatory activities will be performed in a motion capture laboratory.

  1. Walking on level ground at self-selected speed.
  2. Walking on level ground at 15% slower than self-selected speed.
  3. Walking on level ground at 15% faster than self-selected speed.
  4. Walking up an 8% slope at self-selected speed.
  5. Walking down an 8% slope at self-selected speed.
  6. Walking on level ground at self-selected speed while carrying a 5 kg load in one hand on their prosthetic side.
  7. Walking on level but uneven terrain at self-selected speed.
  8. Walking around 2-meter diameter circle at self-selected speed with the prosthetic side on the inside of the circle.
  9. Walking around 2-meter diameter circle at self-selected speed with the prosthetic side on the outside of the circle.

Ambulatory activities 1 through 6 will be performed on an instrumented treadmill. The load to be carried in activity 6 will be configured as a grocery bag with handles. Activity 7 will be performed on a rocky terrain treadmill. Activities 8 and 9 will be performed overground across five force plates embedded in the laboratory floor while following the outline of a 2-meter diameter circle. Rest breaks during all activities will be provided as needed.

The data from this experiment will be used to calculate the peak-to-peak range of the frontal plane whole-body angular momentum (a measure of balance control). The investigators will use these calculations to determine a user- and activity-specific automatic stiffness modulation control scheme intended to improve balance control.

Each participant will then be randomized to wear their fixed stiffness prosthesis or the automatic stiffness prosthesis. Subjects will be fit with the IMU sensors on their ankles, wrists, and upper torso. The automatic stiffness prosthesis will be programmed to emulate the user-specific and activity-specific automatic stiffness modulation control scheme. Subjects will be provided at least 10 minutes to walk about the laboratory to learn how the study prosthesis performs. Subjects, wearing the study prosthesis (fixed or automatic stiffness), will then walk a defined course about the hospital facility (both indoors and outdoors) in which each of the laboratory-based ambulatory activities will be represented. A study investigator will accompany the subject at a following distance of ~5 meters while video recording their gait. After completing the defined course, the subject will return to the laboratory where they will complete the Prosthetic Limb Users Survey of Mobility and the Activities-Specific Balance Confidence Scale questionnaires to assess their perceived functional mobility and balance confidence. The subject will then don the other study prosthesis (fixed or automatic stiffness) and then repeat the walk about the defined course and complete the two questionnaires a second time.

The results of this experiment will determine if automatic stiffness modulation improves the balance control of those with lower-limb amputation as they perform typical ambulatory activities of daily living using both biomechanical analyses and self-report assessments of perceived functional mobility and balance confidence.

The investigators hypothesize that the automatic stiffness prosthesis will provide improved balance control in real-world environments compared to the user's fixed stiffness prosthesis that was clinically prescribed. The investigators further hypothesize that the Prosthetic Limb Users Survey of Mobility score reported after wearing the automatic stiffness prosthesis will be greater than the score reported after wearing the fixed stiffness prosthesis, and the Activities-Specific Balance Confidence Scale score reported after wearing the automatic stiffness prosthesis will be greater than the score reported after wearing the fixed stiffness prosthesis.

Being tested
Fixed stiffness prosthesis, Automatic stiffness prosthesis
Keywords
lower limb prosthesis, transtibial amputation, below knee amputation, biomechanics, gait

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Fixed stiffness prosthesisDevice

    The participant's clinically prescribed prosthesis whose stiffness category is determined by the person's body weight and activity level (standard clinical practice).

  • Automatic stiffness prosthesisDevice

    A novel prosthesis whose user-specific and activity-specific stiffness profile is automatically modulated based on their ambulatory activity.

Study groups in NCT07791433
Study groupRoleWhat they receive
Fixed stiffness prosthesis then automatic stiffness prosthesisExperimentalA within-subject crossover experiment will be conducted to determine if differences in balance control (peak-to-peak range of frontal plane whole body angular momentum) exist between two study prostheses. The two study prostheses include (1) the participant's fixed stiffness prosthesis and (2) a novel, automatic stiffness prosthesis. The order in which participants wore the study prostheses was randomized. The study will be conducted over 2 weeks. All participants will walk a defined course (both indoors and outdoors) about a hospital facility. Participants in this group will wear their fixed stiffness prosthesis first and then the automatic stiffness prosthesis.
Receives: Device: Fixed stiffness prosthesis; Device: Automatic stiffness prosthesis
Automatic stiffness prosthesis then fixed stiffness prosthesisExperimentalA within-subject crossover experiment will be conducted to determine if differences in balance control (peak-to-peak range of frontal plane whole body angular momentum) exist between two study prostheses. The two study prostheses include (1) the participant's fixed stiffness prosthesis and (2) a novel, automatic stiffness prosthesis. The order in which participants wore the study prostheses was randomized. The study will be conducted over 2 weeks. All participants will walk a defined course (both indoors and outdoors) about a hospital facility. Participants in this group will wear the automatic stiffness prosthesis and then their fixed stiffness prosthesis.
Receives: Device: Fixed stiffness prosthesis; Device: Automatic stiffness prosthesis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Peak-to-peak range of the frontal plane whole-body angular momentum

    Frontal plane whole-body angular momentum is a measure of the extent to which a person will rotate in the frontal plane in the absence of an external force or torque. The peak-to-peak range quantifies how much this metric varies and is used to describe a person's balance.

    Measured: During study visit (approximately 3 hours)

Secondary outcomes (2)
  1. Prosthetic Limb Users Survey of Mobility

    The Prosthetic Limb Users Survey of Mobility is a self-report instrument designed to measure the mobility of adults with lower limb amputations, utilizing a set of calibrated questions to assess perceived mobility in various activities. The Prosthetic Limb Users Survey of Mobility has been recommended by the National Institute of Child Health and Human Development as a core Common Data Element for lower-limb loss research as outcome measures to assess mobility.

    Measured: During study visit (approximately 3 hours)

  2. Activities-Specific Balance Confidence Scale

    The Activities-Specific Balance Confidence Scale is a 16-item self-report questionnaire that measures an individual's confidence in performing daily activities without losing balance or feeling unsteady. It is widely used to identify individuals at risk of falls and to guide interventions aimed at improving balance and mobility. The Activities-Specific Balance Confidence Scale has been recommended by National Institute of Child Health and Human Development as a core Common Data Element for lower-limb loss research as an outcome measure to assess balance.

    Measured: During study visit (approximately 3 hours)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Aug 2026
  2. Study startNov 2026 (estimated)
  3. Primary completionNov 2027 (estimated)
  4. Study completionNov 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07791433
Sponsor's protocol ID
1817327-27
Other IDs
1R01HD111514-01A1
Status last verified
Aug 2026
First submitted
10 Aug 2026
Last updated
28 Aug 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Yes: De-identified data sets of all individual participant data collected throughout the trial will be made available, in machine-readable format, on the Eunice Kennedy Shriver National Institute of Child Health and Human Development Data and Specimen Hub. The de-identification procedures will follow 164.514(a) of the Health Insurance Portability and Accountability Act Privacy Rule.

Questions about this trial

What is this clinical trial studying?

A study testing Fixed stiffness prosthesis and Automatic stiffness prosthesis in people with Lower Limb Amputation Below Knee, run by Seattle Institute for Biomedical and Clinical Research at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 28 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Peak-to-peak range of the frontal plane whole-body angular momentum (time frame: During study visit (approximately 3 hours)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Aug 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in