Diabetes MellitusPROMISE-GXNCT07802327
PMCF Study of GX-01S CGM in Adults With Diabetes
A study testing GX-01S Continuous Glucose Monitoring System in people with Diabetes Mellitus and Diabetes Mellitus ( Type 1 and Type 2), run by MicroTech Medical(Hangzhou)Co.,Ltd..
Trial summary
This clinical study evaluates the GX-01S Continuous Glucose Monitoring (CGM) System in adults with Type 1 or Type 2 diabetes. CGM systems measure glucose levels continuously throughout the day, providing real-time information that can help patients manage their diabetes more effectively. Read more about this study
- Who is it for?
- Ages 18 to 75 years
- Conditions the study is for
- Diabetes Mellitus, Diabetes Mellitus ( Type 1 and Type 2)
- What is being tested?
- GX-01S Continuous Glucose Monitoring System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 100 participants
- Where
- No sites listed yet
- Study dates
- Sep 2026to Jun 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 75 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient age is between 18 and 75 years old.
- Patient is clinically diagnosed with diabetes (T1D or T2D), with more than 50% on a stable insulin regimen, defined as no change in the prescribed number of basal insulin administrations per day and less than 10% change in basal total daily insulin dose within 3 months prior to enrollment. Patients not using insulin are considered having a stable treatment regimen if their diabetes management (lifestyle measures and/or non-insulin glucose-lowering medications) has remained unchanged within 3 months prior to enrollment and no treatment intensification is anticipated during the blinded phase.
- Patient has a HbA1c of >7.5%.
- Patient and investigator signed and dated the informed consent form prior to first sensor placement.
Who cannot join
- Use of any type of rtCGM within 3 months prior to study entry.
- Severe hypoglycemia requiring assistance from another individual within the last 12 months, or seizure or loss of consciousness within the last 3 years.
- Severe hyperglycemia, that required hospitalization within the last 6 months.
- More than one diabetic ketoacidosis (DKA) event in the past year.
- History of seizures other than due to hypoglycemia.
- Myocardial infarction or stroke within the past 6 month.
Show all 17Show fewer
- Estimated glomerular filtration rate (eGFR) < 30 mL/min obtained within the prior 12 months as part of usual care, or kidney transplant.
- Requirement to undergo magnetic resonance imaging (MRI) during the study period.
- Most recent thyroid function test results abnormal, obtained as part of usual care within the prior 2 years.
- Presence of a significant medical or psychiatric disorder, or use of a medication that, in the judgment of the investigator, will affect the wearing of sensors, completion of any aspect of the protocol, or increase risk.
- Cognitive difficulties that, in the judgment of the investigator, could impair the individual's ability to follow the protocol or increase risk.
- Inpatient psychiatric treatment within the past 6 months.
- Currently pregnant, lactating, or planning to become pregnant during the study period (within the past 1 month).
- Deemed unsuitable by investigators due to any condition that impacts the reliability of HbA1c measurement.
- Patient is unable / unwilling to provide informed consent.
- Patient is unable to comply with the protocol or proposed follow-up visits.
- Patient who is currently enrolled in another clinical study, or has recently participated in a clinical study, that could potentially interfere with the outcomes or introduce bias into the results of the current study (as determined by the investigator). This includes studies involving investigational drugs, medical devices, or other interventions that could impact the safety, efficacy, or scientific integrity of this study.
Trial locations and contacts
No sites are listed yet. Contact the study team or a site near you to ask about taking part.
Tim Enis contact
About this study
Official title: PROspective Post-Market Clinical Follow-Up (PMCF) Study to Assess the Clinical Benefits of the GX-01S Continuous Glucose Monitoring System in Adult Patients With Diabetes Type 1 and Type 2
This clinical study evaluates the GX-01S Continuous Glucose Monitoring (CGM) System in adults with Type 1 or Type 2 diabetes. CGM systems measure glucose levels continuously throughout the day, providing real-time information that can help patients manage their diabetes more effectively.
The study aims to determine whether using the GX-01S CGM System improves glycemic control, as measured by Time in Range (the percentage of time glucose levels stay within a target range). It will also assess safety, treatment satisfaction, quality of life, and ease of use of the device.
Read more
Participants will wear the GX-01S CGM System for approximately 135 days (about 4.5 months). The first 15 days will be a "blinded" period where participants cannot see their glucose readings, which will be used to establish a baseline. For the remaining 120 days, participants will have full access to their real-time glucose data. Participants will visit the study site at the beginning, Day 15, Day 45, and Day 135 for assessments and questionnaires.
The study will enroll 100 adult patients across multiple centers in Europe. Enrollment is expected to begin in September 2026.
Read the detailed description
Diabetes mellitus remains one of the most prevalent chronic diseases worldwide, contributing significantly to morbidity, mortality, and healthcare costs. For individuals with Type 1 Diabetes (T1D) and many with Type 2 Diabetes (T2D), insulin therapy is essential for maintaining glycemic control and preventing acute and long-term complications. Traditional self-monitoring of blood glucose (SMBG) via fingertip testing, while effective, has limitations including pain, inconvenience, and the inability to capture glucose trends or nocturnal fluctuations.
Continuous Glucose Monitoring Systems (CGMS) have emerged as a transformative technology in diabetes management. By measuring interstitial glucose levels at frequent intervals, CGMS offers real-time glucose data, trend information, and alerts for hypo- and hyperglycemic events. These features support more informed treatment decisions, reduce the burden of fingertip testing, and have been shown to improve glycemic outcomes such as Time In Range (TIR) and Hemoglobin A1c (HbA1c).
Despite the growing adoption of CGMS, real-world evidence on patient acceptance, clinical benefits, and the impact of device-specific features-such as remote data sharing and retrospective pattern analysis-remains limited, particularly in European populations. Furthermore, understanding the reasons for device discontinuation, including skin reactions, sensor insertion burden, and body image concerns, is critical for optimizing patient-centered care.
The GX-01S Continuous Glucose Monitoring System is a single-use, real-time medical device designed to provide continuous interstitial glucose readings for the management of diabetes. The system consists of three primary components: (1) a sterile sensor with an integrated applicator, (2) a transmitter for wireless data transfer, and (3) the LinX mobile application for real-time display and alert management. The sensor is designed for a wear life of up to 15 days.
This PROspective Post-Market Clinical Follow-Up (PMCF) study aims to evaluate the clinical benefits of the GX-01S CGM System in adult patients with diabetes. The investigation will focus on improvements in glycemic control, treatment satisfaction, device usability, quality of life, and safety outcomes in a real-world European cohort. Findings from this study are intended to support the clinical utility and patient acceptance of CGMS as a standard of care in diabetes management.
The primary objective of this study is to demonstrate that use of the GX-01S CGM System can improve glycemic control, as measured by an improvement in CGM-derived glycemic metrics (TIR, Time Above Range [TAR], and Time Below Range [TBR]) after 30 days of device usage, compared to baseline. Baseline is defined as the blinded 15-day CGM run-in period during which participants use the GX-01S CGM without access to real-time glucose data.
The secondary objectives are to assess efficacy, ease of use, and safety of the GX-01S CGM System, as well as patient treatment satisfaction and quality of life. Secondary outcomes include change in HbA1c, treatment satisfaction measured by the Diabetes Treatment Satisfaction Questionnaire (DTSQ), satisfaction and quality of life measured by the CGM Satisfaction Scale (CGM-SAT), device usability measured by the Post-Study System Usability Questionnaire (PSSUQ), and the number and type of (serious) adverse events and device deficiencies.
The study is a post-market, commercial, prospective, interventional, single-arm multicenter study. A total of 100 adult patients with T1D and T2D will be enrolled, with at least 70% being T1D patients and more than 50% on a stable insulin regimen. Enrollment will take place across multiple centers in Europe. Participants will be followed for approximately 135 days (about 4.5 months), consisting of a 15-day blinded run-in period and a 120-day unblinded period with full access to real-time glucose data.
The sensor insertion is a minimally invasive procedure performed by the participant under the supervision of qualified site staff. Sensors will be applied to the back of the upper arm and replaced every 15 days. Participants will use a study-specific blinded application during the run-in period and the commercial LinX application during the unblinded period. Investigators will have remote access to sensor data through the Pancares Web Portal for monitoring and data collection.
The study has received ethical approval from the relevant Ethics Committees and will be conducted in compliance with ISO 14155, the Declaration of Helsinki, and the EU Medical Device Regulation (MDR) 2017/745. Results will be published to support the clinical utility of the GX-01S CGM System in diabetes management.
- Being tested
- GX-01S Continuous Glucose Monitoring System
- Keywords
- Continuous Glucose Monitoring, Time in Range, Diabetes Mellitus, Post-Market Clinical Follow-up
- Medical subject headings
- Diabetes Mellitus
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
GX-01S Continuous Glucose Monitoring SystemDevice
The GX-01S CGM System is a single-use, real-time continuous glucose monitoring device designed to provide interstitial glucose readings for the management of diabetes. The system consists of three primary components: (1) a sterile sensor with an integrated applicator, (2) a transmitter for wireless data transfer, and (3) the LinX mobile application for real-time display and alert management. The sensor is designed for a wear life of up to 15 days and provides glucose readings every minute. The system includes customizable alerts for high/low glucose levels and allows for remote data sharing through the Pancares Web Portal.
| Study group | Role | What they receive |
|---|---|---|
| GX-01S Continuous Glucose Monitoring System | Experimental | All participants will use the GX-01S Continuous Glucose Monitoring (CGM) System. The study consists of a 15-day blinded run-in period during which participants wear the sensor but do not have access to real-time glucose data (baseline period), followed by a 120-day unblinded period during which participants have full access to real-time glucose data and all app functionalities. Sensors are worn continuously and replaced every 15 days. Total study duration is approximately 135 days (about 4.5 months) per participant. Receives: Device: GX-01S Continuous Glucose Monitoring System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR) from Blinded Baseline to Unblinded CGM Use
Measured: 15-day blinded run-in period compared to Day 45 unblinded follow-up visit
Change in Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR) from Blinded Baseline to Unblinded CGM Use
Change in CGM-derived glycemic metrics: Time in Range (TIR, 70-180 mg/dL), Time Above Range (TAR, >180 mg/dL), and Time Below Range (TBR, <70 mg/dL). Calculated using blinded CGM data from the 15-day run-in period compared to unblinded CGM data at the Day 45 follow-up visit.
Measured: 15-day blinded run-in period (Visit 2 to Visit 3) compared to Day 45 unblinded follow-up visit (Visit 3 to Visit 4)
Secondary outcomes (1)
Change in Hemoglobin A1c (HbA1c)
Change in HbA1c from baseline (Visit 1) to end of study (Visit 5, Day 135).
Measured: Baseline (Visit 1) to End of Study (Visit 5, Day 135)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Sep 2026
- Study startSep 2026 (estimated)
- Primary completionFeb 2028 (estimated)
- Study completionJun 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Diabetes MellitusStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 100 participants (estimated)
Sponsor and investigators
- Lead sponsor
- MicroTech Medical(Hangzhou)Co.,Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Julia Mader, Professor, M.D., Principal investigator, Medical University of Graz
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07802327
- Sponsor's protocol ID
- PROMISE-GX
- Acronym
- PROMISE-GX
- Status last verified
- Sep 2026
- First submitted
- 31 Aug 2026
- Last updated
- 9 Sep 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 Sep 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- PROspective Post-Market Clinical Follow-Up (PMCF) Study to Assess the Clinical Benefits of the GX-01S Continuous Glucose Monitoring System in Adult Patients With Diabetes Type 1 and Type 2
- ClinicalTrials.gov ID
- NCT07802327
- Acronym / sponsor ID
- PROMISE-GX / PROMISE-GX
- Keywords
- Continuous Glucose Monitoring, Time in Range, Diabetes Mellitus, Post-Market Clinical Follow-up
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 100 participants (estimated)
- Lead sponsor
- MicroTech Medical(Hangzhou)Co.,Ltd.Industry (pharma, biotech, devices)
- Study start
- Sep 2026 (estimated)
- Primary completion
- Feb 2028 (estimated)
- Study completion
- Jun 2028 (estimated)
- First posted
- 3 Sep 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This clinical study evaluates the GX-01S Continuous Glucose Monitoring (CGM) System in adults with Type 1 or Type 2 diabetes. CGM systems measure glucose levels continuously throughout the day, providing real-time information that can help patients manage their diabetes more effectively.
The study aims to determine whether using the GX-01S CGM System improves glycemic control, as measured by Time in Range (the percentage of time glucose levels stay within a target range). It will also assess safety, treatment satisfaction, quality of life, and ease of use of the device.
Participants will wear the GX-01S CGM System for approximately 135 days (about 4.5 months). The first 15 days will be a "blinded" period where participants cannot see their glucose readings, which will be used to establish a baseline. For the remaining 120 days, participants will have full access to their real-time glucose data. Participants will visit the study site at the beginning, Day 15, Day 45, and Day 135 for assessments and questionnaires.
The study will enroll 100 adult patients across multiple centers in Europe. Enrollment is expected to begin in September 2026.
Detailed description
Diabetes mellitus remains one of the most prevalent chronic diseases worldwide, contributing significantly to morbidity, mortality, and healthcare costs. For individuals with Type 1 Diabetes (T1D) and many with Type 2 Diabetes (T2D), insulin therapy is essential for maintaining glycemic control and preventing acute and long-term complications. Traditional self-monitoring of blood glucose (SMBG) via fingertip testing, while effective, has limitations including pain, inconvenience, and the inability to capture glucose trends or nocturnal fluctuations.
Continuous Glucose Monitoring Systems (CGMS) have emerged as a transformative technology in diabetes management. By measuring interstitial glucose levels at frequent intervals, CGMS offers real-time glucose data, trend information, and alerts for hypo- and hyperglycemic events. These features support more informed treatment decisions, reduce the burden of fingertip testing, and have been shown to improve glycemic outcomes such as Time In Range (TIR) and Hemoglobin A1c (HbA1c).
Despite the growing adoption of CGMS, real-world evidence on patient acceptance, clinical benefits, and the impact of device-specific features-such as remote data sharing and retrospective pattern analysis-remains limited, particularly in European populations. Furthermore, understanding the reasons for device discontinuation, including skin reactions, sensor insertion burden, and body image concerns, is critical for optimizing patient-centered care.
The GX-01S Continuous Glucose Monitoring System is a single-use, real-time medical device designed to provide continuous interstitial glucose readings for the management of diabetes. The system consists of three primary components: (1) a sterile sensor with an integrated applicator, (2) a transmitter for wireless data transfer, and (3) the LinX mobile application for real-time display and alert management. The sensor is designed for a wear life of up to 15 days.
This PROspective Post-Market Clinical Follow-Up (PMCF) study aims to evaluate the clinical benefits of the GX-01S CGM System in adult patients with diabetes. The investigation will focus on improvements in glycemic control, treatment satisfaction, device usability, quality of life, and safety outcomes in a real-world European cohort. Findings from this study are intended to support the clinical utility and patient acceptance of CGMS as a standard of care in diabetes management.
The primary objective of this study is to demonstrate that use of the GX-01S CGM System can improve glycemic control, as measured by an improvement in CGM-derived glycemic metrics (TIR, Time Above Range [TAR], and Time Below Range [TBR]) after 30 days of device usage, compared to baseline. Baseline is defined as the blinded 15-day CGM run-in period during which participants use the GX-01S CGM without access to real-time glucose data.
The secondary objectives are to assess efficacy, ease of use, and safety of the GX-01S CGM System, as well as patient treatment satisfaction and quality of life. Secondary outcomes include change in HbA1c, treatment satisfaction measured by the Diabetes Treatment Satisfaction Questionnaire (DTSQ), satisfaction and quality of life measured by the CGM Satisfaction Scale (CGM-SAT), device usability measured by the Post-Study System Usability Questionnaire (PSSUQ), and the number and type of (serious) adverse events and device deficiencies.
The study is a post-market, commercial, prospective, interventional, single-arm multicenter study. A total of 100 adult patients with T1D and T2D will be enrolled, with at least 70% being T1D patients and more than 50% on a stable insulin regimen. Enrollment will take place across multiple centers in Europe. Participants will be followed for approximately 135 days (about 4.5 months), consisting of a 15-day blinded run-in period and a 120-day unblinded period with full access to real-time glucose data.
The sensor insertion is a minimally invasive procedure performed by the participant under the supervision of qualified site staff. Sensors will be applied to the back of the upper arm and replaced every 15 days. Participants will use a study-specific blinded application during the run-in period and the commercial LinX application during the unblinded period. Investigators will have remote access to sensor data through the Pancares Web Portal for monitoring and data collection.
The study has received ethical approval from the relevant Ethics Committees and will be conducted in compliance with ISO 14155, the Declaration of Helsinki, and the EU Medical Device Regulation (MDR) 2017/745. Results will be published to support the clinical utility of the GX-01S CGM System in diabetes management.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| GX-01S Continuous Glucose Monitoring System | Experimental | Device: GX-01S Continuous Glucose Monitoring SystemAll participants will use the GX-01S Continuous Glucose Monitoring (CGM) System. The study consists of a 15-day blinded run-in period during which participants wear the sensor but do not have access to real-time glucose data (baseline period), followed by a 120-day unblinded period during which participants have full access to real-time glucose data and all app functionalities. Sensors are worn continuously and replaced every 15 days. Total study duration is approximately 135 days (about 4.5 months) per participant. |
Who may qualify
- Ages
- 18 to 75 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Patient age is between 18 and 75 years old.
- Patient is clinically diagnosed with diabetes (T1D or T2D), with more than 50% on a stable insulin regimen, defined as no change in the prescribed number of basal insulin administrations per day and less than 10% change in basal total daily insulin dose within 3 months prior to enrollment. Patients not using insulin are considered having a stable treatment regimen if their diabetes management (lifestyle measures and/or non-insulin glucose-lowering medications) has remained unchanged within 3 months prior to enrollment and no treatment intensification is anticipated during the blinded phase.
- Patient has a HbA1c of >7.5%.
- Patient and investigator signed and dated the informed consent form prior to first sensor placement.
Key exclusion criteria (17 listed)
- Use of any type of rtCGM within 3 months prior to study entry.
- Severe hypoglycemia requiring assistance from another individual within the last 12 months, or seizure or loss of consciousness within the last 3 years.
- Severe hyperglycemia, that required hospitalization within the last 6 months.
- More than one diabetic ketoacidosis (DKA) event in the past year.
- History of seizures other than due to hypoglycemia.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| GX-01S Continuous Glucose Monitoring SystemThe GX-01S CGM System is a single-use, real-time continuous glucose monitoring device designed to provide interstitial glucose readings for the management of diabetes. The system consists of three primary components: (1) a sterile sensor with an integrated applicator, (2) a transmitter for wireless data transfer, and (3) the LinX mobile application for real-time display and alert management. The sensor is designed for a wear life of up to 15 days and provides glucose readings every minute. The system includes customizable alerts for high/low glucose levels and allows for remote data sharing through the Pancares Web Portal. | Device | GX-01S Continuous Glucose Monitoring System |
Primary outcome
Change in Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR) from Blinded Baseline to Unblinded CGM Use
Time frame: 15-day blinded run-in period compared to Day 45 unblinded follow-up visit
Change in Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR) from Blinded Baseline to Unblinded CGM Use
Time frame: 15-day blinded run-in period (Visit 2 to Visit 3) compared to Day 45 unblinded follow-up visit (Visit 3 to Visit 4)
Change in CGM-derived glycemic metrics: Time in Range (TIR, 70-180 mg/dL), Time Above Range (TAR, >180 mg/dL), and Time Below Range (TBR, <70 mg/dL). Calculated using blinded CGM data from the 15-day run-in period compared to unblinded CGM data at the Day 45 follow-up visit.
1 secondary outcome
Change in Hemoglobin A1c (HbA1c)
Time frame: Baseline (Visit 1) to End of Study (Visit 5, Day 135)
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Sep 2026.
- Individual participant dataSharing planned: No
Related trials for Diabetes Mellitus
Not yet recruitingPhase 3
Efficacy and Safety of Once-Weekly SHR-3167 Compared With Once-Daily Insulin Glargine in Adults With Insulin-Naive Type 2 Diabetes
Type 2 Diabetes
Active, not recruiting
Digital Reinforcement of Motivational Interviewing Micro-Skills Among Primary Care Healthcare Professionals
Hypertension (Without Type 2 Diabetes Mellitus)
Recruiting
Effects of Lean Pork Loin Intake on Protein Homeostasis and Glucose Regulation in Prediabetic Adults
Hyperglycaemia (Non Diabetic), Prediabetes
Recruiting
PAW-Hydrogel for Chronic Wound Healing
Diabetic Foot Ulcer (DFU), Pressure Ulcer (PU)
Recruiting
Investigating Vascular Properties of HEMI and SPG Signals in Individuals With or at Risk for Chronic Kidney Disease
Chronic Kidney Disease, Hypertension (HTN)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Tim Enis contact
Julia Mader, Professor, M.D. principal investigator
Medical University of Graz
Questions about this trial
What is this clinical trial studying?
A study testing GX-01S Continuous Glucose Monitoring System in people with Diabetes Mellitus and Diabetes Mellitus ( Type 1 and Type 2), run by MicroTech Medical(Hangzhou)Co.,Ltd..
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 17 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 9 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Maudline Abra Novihoho (+8613648604281, na.mao@microtechmd.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR) from Blinded Baseline to Unblinded CGM Use (time frame: 15-day blinded run-in period compared to Day 45 unblinded follow-up visit). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.