ESD DefectNCT07843719
Su2ura ESD Closure Pilot Study
A study testing Su2ura® GI system in people with ESD Defect and Gastric Epithelial Lesion, run by Chinese University of Hong Kong.
Trial summary
This study is a single-center, prospective, single-arm, non-blinded first-in-human (FIH) early feasibility study intended to evaluate the short-term safety and technical feasibility of closure of gastric post-ESD defects using a novel through-the-scope full-thickness endoscopic suturing system in initial human use. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- ESD Defect, Gastric Epithelial Lesion
- What is being tested?
- Su2ura® GI system
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 5 participants
- Where
- No sites listed yet
- Study dates
- 1 Oct 2026to 31 Mar 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age 18 years or older
- Patients scheduled to undergo gastric ESD for gastric epithelial lesions
- Patients who have received sufficient explanation of this study and from whom written informed consent has been obtained by their own free will
- Patients judged by the principal investigator or sub-investigator to be appropriate for participation in this study
Who cannot join
- Perforation cases requiring emergency closure
- Cases with severe coagulation abnormalities, bleeding tendency, or other serious systemic conditions, in whom participation in the study is judged to be inappropriate
- Cases who are pregnant or may be pregnant
- Cases in whom obtaining consent for this study is difficult, including minor patients
- Other cases judged to be inappropriate by the principal investigator or sub-investigator
Trial locations and contacts
No sites are listed yet. Contact the study team or a site near you to ask about taking part.
About this study
Official title: The Utility of a Novel Endoscopic Suturing System in Closing Gastrointestinal Defect - a Pilot Human Study
This study is a single-center, prospective, single-arm, non-blinded first-in-human (FIH) early feasibility study intended to evaluate the short-term safety and technical feasibility of closure of gastric post-ESD defects using a novel through-the-scope full-thickness endoscopic suturing system in initial human use.
The subjects shall be patients scheduled to undergo ESD for gastric epithelial lesions at the study site (Prince of Wales Hospital) in Hong Kong who meet the eligibility criteria for this study and from whom written informed consent has been obtained. For the gastric defects created after completion of ESD, closure will be attempted using the study device, and its safety, technical success, and early postoperative maintenance of closure will be evaluated.
Read more
The target sample size of this study shall be 5 cases, and no control group shall be established. No comparison with existing defect closure techniques or verification of superiority will be performed. From the viewpoint of patient protection, comparatively controllable gastric post-ESD defects are selected as the entry model, and the safety signal and basic technical success of this device in its initial human use will be evaluated descriptively.
The device specifications used in this study shall remain fixed throughout the study period. During the registration period of the initial cohort of 5 cases, no major changes shall be made to the device itself, accessory equipment, procedural concept, or primary evaluation methods. If device improvement or procedural modification becomes necessary during the study, it shall be handled separately from this initial cohort after obtaining approval from the ethics committee and other relevant authorities, as necessary.
Read the detailed description
Endoscopic suturing platforms are expected to have future applications in more advanced interventional settings, including closure of full-thickness defects, treatment of perforations and fistulas, management of post-resection defects, and bariatric endoscopy. Full-thickness suturing may offer theoretical advantages for larger or deeper defects that are difficult to manage with conventional clip-based methods. At the same time, currently available devices still have important limitations, including technical complexity, restricted maneuverability, and cumbersome setup. For this reason, development of a simpler through-the-scope suturing platform is clinically meaningful.
The Su2ura® GI System was developed as a novel through-the-scope full-thickness endoscopic suturing platform. In preclinical animal experiments, it showed feasibility through a standard endoscopic working channel, a relatively short learning curve, successful full-thickness tissue capture, and acceptable histologic tissue response. The device has demonstrated significant potential as a robust suturing device that could be applied in a number of clinical settings owing to its simplicity in use. Human use of Su2ura® GI system has not yet been reported.
Although the clinical settings in which this device may ultimately be used included full-thickness defects, perforations, fistulas, and bariatric interventions, these are all relatively high-risk situations with considerable risks when adverse event occurs. When introducing a novel device or procedure into clinical practice, it is important not to begin directly in the highest-risk indication, but instead to first establish proof of principle and initial safety in a controlled and predictable setting. The IDEAL framework recommends staged evaluation of new procedures and devices, beginning with small prospective series and emphasizing prospective registration, sequential reporting, and transparent documentation of technical development. Similarly, the FDA guidance on early feasibility studies describes such studies as small clinical investigations intended to obtain proof of principle and initial clinical safety data when nonclinical testing alone is not sufficient to support further development.
Based on the above rationale, closure of post-ESD gastric defects was selected as the target clinical setting for first-in-human study. Post-ESD gastric defects provide a suitable setting for this purpose because they are created during a planned procedure, the location and extent of the defect can be assessed directly during the intervention, and established rescue options remain available if suturing is incomplete or unsuccessful. Compared with true full-thickness defects or perforation cases, this setting is therefore associated with a lower incremental risk when introducing a novel suturing device into human use. Several methods have been described for closure of gastric post-ESD defects, but each has its own advantages and limitations, and no single method has been established as optimal in all situations. Therefore, post-ESD gastric defects should not be regarded as the final target indication of this device, but rather as a controlled clinical entry model in which its basic operability and short-term safety can be assessed in humans before moving to more complex and higher-risk applications.
Accordingly, the purpose of this study is not to demonstrate superiority over existing closure methods or to establish the value of routine closure after gastric ESD. Rather, this study is designed to evaluate the short-term safety and procedural feasibility of a novel through-the-scope full-thickness suturing system under conditions that provide the greatest degree of patient protection for initial human use.
- Conditions
- ESD Defect, Gastric Epithelial Lesion
- Being tested
- Su2ura® GI system
- Keywords
- ESD defect, Suturing, gastric lesion, Su2ura® GI System
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Su2ura® GI systemDevice
The Su2ura® O System is a sterile single-use system intended for endoscopic full-thickness approximation of soft tissue through commonly used endoscopic working channels in both the upper and lower gastrointestinal tract.
The system comprises of 3 sterile single-use parts; (1) a flexible endoscopic suturing device (Su2ura® O Device), (2) magazine pre-loaded with up to 6 threaded (0.30mm UHMWPE Braided Cord) nitinol T-Anchors and (3) a suture lock and thread cutting mechanism (Su2ura® Knot Device); the system is planned to be used through a commonly used endoscopic working channels. Each anchor is deployed by a single trigger operation. The sutures are aimed to be 'full-thickness' and are achieved using threaded nitinol T-anchors with a reduced friction mechanism, which enables fast tightening. The sutures are designed to be widely used by any interventional endoscopists in all endoscopic suites for procedures performed in both the upper and lower gastrointestinal tract.
| Study group | Role | What they receive |
|---|---|---|
| Su2ura® GI System Group | Experimental | For the gastric defect created after completion of ESD, closure will be attempted using the study device. Anchors shall be placed alternately on both ends of the defect and repeated until the wound is completely closed. The interval between anchors should be aimed at the discretion of the endoscopist, and the anchors should ideally be placed within 5-10 mm from the edge of the defect. If the defect is large and dead space is likely to be formed during closure, additional anchors shall also be placed on the ulcer base so as to eliminate the dead space. The closure procedure shall be performed by an operator who has received appropriate prior training in the use of the device. Receives: Device: Su2ura® GI system |
What is being measured
The primary outcome is the main question the study is designed to answer.
Incidence of device-related adverse events
The primary endpoint shall be the incidence of device-related adverse events and serious adverse events occurring during the procedure or within 30 days postoperatively.
Measured: 30 days
Secondary outcomes (7)
Technical success
The proportion of cases in which the planned defect closure procedure could be performed using the study device according to the intended procedure.
Measured: 1 day
Complete closure at the end of the procedure
The proportion of cases in which complete closure was endoscopically achieved at the end of the procedure.
Measured: 1 day
Closure procedure time
The net time from the start of closure manipulation using the study device until completion of closure or termination of the procedure.
Measured: 1 day
Number of anchors / suturing elements used
The number of anchors and locks or suturing elements required for closure.
Measured: 1 day
Need for rescue treatment
The proportion of cases requiring additional treatment using standard closure techniques.
Measured: 30 days
Maintenance of closure at second-look endoscopy
The proportion of cases in which closure was maintained at the time of second-look endoscopy.
Measured: 5 day
Incidence of procedure-related clinical adverse events within 30 days
Incidence of clinically significant postoperative adverse events within 30 days, regardless of causality, including delayed bleeding, delayed perforation, infection, unplanned hospitalization, additional endoscopic treatment, or re-intervention.
Measured: 30 days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Sep 2026
- Study start1 Oct 2026 (estimated)
- Primary completion30 Sep 2027 (estimated)
- Study completion31 Mar 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for ESD DefectStudies of the same condition, open and under way.
- More trials run by Chinese University of Hong KongThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 5 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Chinese University of Hong Kong
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Hon Chi Yip, Chinese University of Hong Kong
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07843719
- Sponsor's protocol ID
- CRE-2026.495
- Status last verified
- Sep 2026
- First submitted
- 22 Sep 2026
- Last updated
- 28 Sep 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 28 Sep 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Utility of a Novel Endoscopic Suturing System in Closing Gastrointestinal Defect - a Pilot Human Study
- ClinicalTrials.gov ID
- NCT07843719
- Acronym / sponsor ID
- CRE-2026.495
- Conditions
- ESD Defect, Gastric Epithelial Lesion
- Keywords
- ESD defect, Suturing, gastric lesion, Su2ura® GI System
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 5 participants (estimated)
- Lead sponsor
- Chinese University of Hong KongUniversity, hospital or other
- Study start
- 1 Oct 2026 (estimated)
- Primary completion
- 30 Sep 2027 (estimated)
- Study completion
- 31 Mar 2028 (estimated)
- First posted
- 28 Sep 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is a single-center, prospective, single-arm, non-blinded first-in-human (FIH) early feasibility study intended to evaluate the short-term safety and technical feasibility of closure of gastric post-ESD defects using a novel through-the-scope full-thickness endoscopic suturing system in initial human use.
The subjects shall be patients scheduled to undergo ESD for gastric epithelial lesions at the study site (Prince of Wales Hospital) in Hong Kong who meet the eligibility criteria for this study and from whom written informed consent has been obtained. For the gastric defects created after completion of ESD, closure will be attempted using the study device, and its safety, technical success, and early postoperative maintenance of closure will be evaluated.
The target sample size of this study shall be 5 cases, and no control group shall be established. No comparison with existing defect closure techniques or verification of superiority will be performed. From the viewpoint of patient protection, comparatively controllable gastric post-ESD defects are selected as the entry model, and the safety signal and basic technical success of this device in its initial human use will be evaluated descriptively.
The device specifications used in this study shall remain fixed throughout the study period. During the registration period of the initial cohort of 5 cases, no major changes shall be made to the device itself, accessory equipment, procedural concept, or primary evaluation methods. If device improvement or procedural modification becomes necessary during the study, it shall be handled separately from this initial cohort after obtaining approval from the ethics committee and other relevant authorities, as necessary.
Detailed description
Endoscopic suturing platforms are expected to have future applications in more advanced interventional settings, including closure of full-thickness defects, treatment of perforations and fistulas, management of post-resection defects, and bariatric endoscopy. Full-thickness suturing may offer theoretical advantages for larger or deeper defects that are difficult to manage with conventional clip-based methods. At the same time, currently available devices still have important limitations, including technical complexity, restricted maneuverability, and cumbersome setup. For this reason, development of a simpler through-the-scope suturing platform is clinically meaningful.
The Su2ura® GI System was developed as a novel through-the-scope full-thickness endoscopic suturing platform. In preclinical animal experiments, it showed feasibility through a standard endoscopic working channel, a relatively short learning curve, successful full-thickness tissue capture, and acceptable histologic tissue response. The device has demonstrated significant potential as a robust suturing device that could be applied in a number of clinical settings owing to its simplicity in use. Human use of Su2ura® GI system has not yet been reported.
Although the clinical settings in which this device may ultimately be used included full-thickness defects, perforations, fistulas, and bariatric interventions, these are all relatively high-risk situations with considerable risks when adverse event occurs. When introducing a novel device or procedure into clinical practice, it is important not to begin directly in the highest-risk indication, but instead to first establish proof of principle and initial safety in a controlled and predictable setting. The IDEAL framework recommends staged evaluation of new procedures and devices, beginning with small prospective series and emphasizing prospective registration, sequential reporting, and transparent documentation of technical development. Similarly, the FDA guidance on early feasibility studies describes such studies as small clinical investigations intended to obtain proof of principle and initial clinical safety data when nonclinical testing alone is not sufficient to support further development.
Based on the above rationale, closure of post-ESD gastric defects was selected as the target clinical setting for first-in-human study. Post-ESD gastric defects provide a suitable setting for this purpose because they are created during a planned procedure, the location and extent of the defect can be assessed directly during the intervention, and established rescue options remain available if suturing is incomplete or unsuccessful. Compared with true full-thickness defects or perforation cases, this setting is therefore associated with a lower incremental risk when introducing a novel suturing device into human use. Several methods have been described for closure of gastric post-ESD defects, but each has its own advantages and limitations, and no single method has been established as optimal in all situations. Therefore, post-ESD gastric defects should not be regarded as the final target indication of this device, but rather as a controlled clinical entry model in which its basic operability and short-term safety can be assessed in humans before moving to more complex and higher-risk applications.
Accordingly, the purpose of this study is not to demonstrate superiority over existing closure methods or to establish the value of routine closure after gastric ESD. Rather, this study is designed to evaluate the short-term safety and procedural feasibility of a novel through-the-scope full-thickness suturing system under conditions that provide the greatest degree of patient protection for initial human use.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Su2ura® GI System Group | Experimental | Device: Su2ura® GI systemFor the gastric defect created after completion of ESD, closure will be attempted using the study device. Anchors shall be placed alternately on both ends of the defect and repeated until the wound is completely closed. The interval between anchors should be aimed at the discretion of the endoscopist, and the anchors should ideally be placed within 5-10 mm from the edge of the defect. If the defect is large and dead space is likely to be formed during closure, additional anchors shall also be placed on the ulcer base so as to eliminate the dead space. The closure procedure shall be performed by an operator who has received appropriate prior training in the use of the device. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Age 18 years or older
- Patients scheduled to undergo gastric ESD for gastric epithelial lesions
- Patients who have received sufficient explanation of this study and from whom written informed consent has been obtained by their own free will
- Patients judged by the principal investigator or sub-investigator to be appropriate for participation in this study
Key exclusion criteria (5 listed)
- Perforation cases requiring emergency closure
- Cases with severe coagulation abnormalities, bleeding tendency, or other serious systemic conditions, in whom participation in the study is judged to be inappropriate
- Cases who are pregnant or may be pregnant
- Cases in whom obtaining consent for this study is difficult, including minor patients
- Other cases judged to be inappropriate by the principal investigator or sub-investigator
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Su2ura® GI systemThe Su2ura® O System is a sterile single-use system intended for endoscopic full-thickness approximation of soft tissue through commonly used endoscopic working channels in both the upper and lower gastrointestinal tract. The system comprises of 3 sterile single-use parts; (1) a flexible endoscopic suturing device (Su2ura® O Device), (2) magazine pre-loaded with up to 6 threaded (0.30mm UHMWPE Braided Cord) nitinol T-Anchors and (3) a suture lock and thread cutting mechanism (Su2ura® Knot Device); the system is planned to be used through a commonly used endoscopic working channels. Each anchor is deployed by a single trigger operation. The sutures are aimed to be 'full-thickness' and are achieved using threaded nitinol T-anchors with a reduced friction mechanism, which enables fast tightening. The sutures are designed to be widely used by any interventional endoscopists in all endoscopic suites for procedures performed in both the upper and lower gastrointestinal tract. | Device | Su2ura® GI System Group |
Primary outcome
Incidence of device-related adverse events
Time frame: 30 days
The primary endpoint shall be the incidence of device-related adverse events and serious adverse events occurring during the procedure or within 30 days postoperatively.
7 secondary outcomes
Technical success
Time frame: 1 day
Complete closure at the end of the procedure
Time frame: 1 day
Closure procedure time
Time frame: 1 day
Number of anchors / suturing elements used
Time frame: 1 day
Need for rescue treatment
Time frame: 30 days
Maintenance of closure at second-look endoscopy
Time frame: 5 day
Incidence of procedure-related clinical adverse events within 30 days
Time frame: 30 days
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 28 Sep 2026.
- Individual participant dataSharing planned: No
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Questions about this trial
What is this clinical trial studying?
A study testing Su2ura® GI system in people with ESD Defect and Gastric Epithelial Lesion, run by Chinese University of Hong Kong.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 28 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Hon Chi Yip (+852 3505 2956, hcyip@surgery.cuhk.edu.hk), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Incidence of device-related adverse events (time frame: 30 days). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Sep 2026.