AzTrials
AzTrials

Mandibular FracturesNCT07901686

Z-Shaped Versus Conventional Miniplates for Mandibular Fractures

A study testing Z-shaped titanium miniplate and Conventional titanium miniplates in people with Mandibular Fractures, run by Sana'a University at 2 sites in Yemen.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study compares two different methods of repairing fractures at the front of the lower jaw (the symphysis and parasymphysis). Usually, surgeons fix these displaced fractures using two separate titanium plates, which can be time-consuming to place and lie close to the nerve that supplies feeling to the lower lip… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Mandibular Fractures
What is being tested?
Z-shaped titanium miniplate and Conventional titanium miniplates
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
2 sitesYemen
Study dates
25 Sep 2025to 7 Jun 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Fracture of the symphyseal or parasymphyseal region of the mandible.
  • Medical fitness for surgery under general anesthesia.
  • Displaced fracture.
  • Age 18 years or older.

Who cannot join

  • Edentulous patients.
  • Comminuted, infected, or pathological fractures.
  • Mandibular fractures associated with condylar fractures.
  • Age below 18 years.

Trial locations and contacts

2 sites in 1 country.

Yemen2 sites
  • Al-Gumhouri Teaching Hospital

    Sanaa

  • Al-Kuwait University Hospital

    Sanaa

Other trials in Yemen

About this study

Official title: Z-shaped Miniplate Versus Conventional Two-miniplate Fixation of Symphyseal and Parasymphyseal Mandibular Fractures: a Prospective Comparative Study.

This study compares two different methods of repairing fractures at the front of the lower jaw (the symphysis and parasymphysis). Usually, surgeons fix these displaced fractures using two separate titanium plates, which can be time-consuming to place and lie close to the nerve that supplies feeling to the lower lip and chin. Recently, a single Z-shaped titanium plate was designed to provide the same stability using less hardware, potentially making the surgery easier and safer for the nerve.

The purpose of this study is to compare the use of a single Z-shaped miniplate with the conventional two-miniplate technique in adult patients. The researchers will measure how long the surgery takes, the number of screws needed, and how easy it is to place the plates. After the surgery, patients will be monitored for up to 3 months to compare pain levels, facial swelling, jaw movement (mouth opening and side-to-side movement), nerve function, and how well the bone heals on x-rays.

Read the detailed description

The mandibular symphysis and parasymphysis are exposed to strong bending and twisting forces during function, meaning a single conventional miniplate is usually insufficient to neutralize forces and prevent the inner surface of the bone from opening under muscle pull. The accepted standard for semirigid fixation is two miniplates. However, this technique requires wider surgical exposure, separate contouring of two plates, and carries a risk of nerve injury due to the proximity of the mental foramen. While closed three-dimensional (3D) plates offer cross-bracing with a single implant, they can be difficult to adapt around the mental nerve. The Z-shaped miniplate features two parallel bars joined by an oblique bar; its open edges allow placement without trapping the nerve.

This prospective, quasi-randomised comparative study is conducted at Al-Kuwait University Hospital and Al-Gumhouri Teaching Hospital in Sana'a, Yemen. It aims to evaluate the operative, clinical, and radiographic outcomes of a single Z-shaped miniplate versus two conventional miniplates. Patients undergo open reduction and internal fixation under general anesthesia using a standardized surgical protocol. Clinical follow-up is conducted on postoperative days 1, 2, and 7 to assess pain via visual analogue scale, facial swelling via linear tape measurements, maximum interincisal opening, lateral excursion, and neurosensory status. Radiographic reduction and residual fracture gaps are evaluated via computed tomography or panoramic radiography at 7 days and 3 months postoperatively.

Being tested
Z-shaped titanium miniplate, Conventional titanium miniplates
Keywords
Mandibular Fractures, Miniplate, Z-shaped plate, Internal fixation, Symphysis, Parasymphysis
Medical subject headings
Mandibular Fractures

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Z-shaped titanium miniplateDevice

    Open reduction and internal fixation of the mandibular fracture using a single Z-shaped titanium miniplate

  • Conventional titanium miniplatesDevice

    Open reduction and internal fixation of the mandibular fracture using two 5-hole non-compression titanium miniplates.

Study groups in NCT07901686
Study groupRoleWhat they receive
Z-shaped miniplateExperimentalPatients in this group undergo fixation of the mandibular fracture using a single Z-shaped titanium miniplate.
Receives: Device: Z-shaped titanium miniplate
Conventional miniplatesActive comparatorPatients in this group undergo fixation of the mandibular fracture using two conventional 5-hole non-compression titanium miniplates.
Receives: Device: Conventional titanium miniplates

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Radiographic Evaluation of Fracture Reduction

    Assessment of fracture reduction, hardware stability, and residual fracture gaps evaluated via computed tomography (CT) or panoramic radiography.

    Measured: 7 days and 3 months postoperatively.

Secondary outcomes (5)
  1. Operative Time

    The total surgical time required for plate adaptation, placement, and screw fixation, measured in minutes.

    Measured: Intraoperative

  2. Postoperative Pain

    Patient-reported pain intensity assessed using a standard Visual Analogue Scale (VAS).

    Measured: Postoperative days 1, 2, and 7.

  3. Facial Swelling

    Postoperative edema evaluated using objective linear tape measurements between standard facial landmarks.

    Measured: Postoperative days 1, 2, and 7.

  4. Maximum Interincisal Opening (MIO) and Lateral Excursion

    Measurement of maximum mouth opening and side-to-side jaw movement in millimeters to assess functional recovery.

    Measured: Postoperative days 1, 2, and 7.

  5. Neurosensory Status

    Clinical assessment of the mental nerve function (e.g., using light touch or pinprick testing) to evaluate for potential iatrogenic nerve injury.

    Measured: Postoperative days 1, 2, and 7.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Oct 2026
  2. Study start25 Sep 2025
  3. Primary completion15 Feb 2026
  4. Study completion7 Jun 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Parallel groups
Model description
Participants were allocated by an alternating (odd/even) enrollment number sequence to receive either a single Z-shaped miniplate or two conventional miniplates.
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07901686
Sponsor's protocol ID
OMFS:06.09.2025
Status last verified
Oct 2026
First submitted
22 Oct 2026
Last updated
28 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data will not be shared to protect patient confidentiality and privacy. All relevant data supporting the findings and conclusions of this study will be made available in aggregate form within the published manuscript and its supplementary materials.

Questions about this trial

What is this clinical trial studying?

A study testing Z-shaped titanium miniplate and Conventional titanium miniplates in people with Mandibular Fractures, run by Sana'a University at 2 sites in Yemen.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 28 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Yemen. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Radiographic Evaluation of Fracture Reduction (time frame: 7 days and 3 months postoperatively.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Oct 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in