Clinical trials: Mandibular Fractures
Mandible Fracture
Computer Guided Lag Screw Fixation Versus Conventional Lag Screw Fixation in Anterior Mandibular Fractures
Comparison between computer guided lag screw fixation versus traditional lag screw fixation in open reduction and internal fixation of anterior mandibular fractures.
- Trial name
- NCT03530891
- Testing
- Computer guided lag screw fixation, Conventional lag screw fixation
- Where
- Egypt
- Volunteers
- 26 people
- Sponsor
- Cairo University
Fractures
A New Treatment Protocol for Paediatric Mandibular Condylar Fractures
This study aim to evaluate the clinical and radiographic outcomes of mandibular condylar fractures in pediatrics treated simply with a mandibular manipulation technique accompanied by mouth opening training.
- Trial name
- NCT02237040
- Testing
- Mandibular manipulation technique
- Where
- China
- Volunteers
- 80 people
- Sponsor
- Sun Yat-sen University
Jaw Fractures, Jaw; Fracture, Upper Jaw
Minimally Invasive Dental Occlusion Ties
Patients sustaining fractures of the upper (maxilla) and/or lower (mandible) jaw may be candidates for the minimally invasive technology evaluated in this study.
- Conditions
- Jaw Fractures, Jaw; Fracture, Upper Jaw, Mandibular Fractures, Maxilla Fracture
- Trial name
- NCT04985461
- Testing
- dental occlusion ties maxillo-mandibular fixation
- Where
- United States
- Volunteers
- 10 people
- Sponsor
- Altru Health System
Neurosensory Disturbance, Mandibular Body Fractures
Efficacy Of Platelet Rich Fibrin (PRF) In Neurosensory Disturbance Among Patients With Mandibular Body Fractures
Mandibular body fractures frequently result in inferior alveolar nerve (IAN) and mental nerve injuries which ultimately leads to paresthesia of chin and lower lip area.
- Trial name
- PRF NSD (NCT07319650)
- Testing
- Platelets rich Fibrin
- Where
- Pakistan
- Volunteers
- 40 people
- Sponsor
- University of Health Sciences Lahore
Mandibular Fractures
Computer Guided Screw Holes Locating Guide and Custom-made Plates
Preoperative CT. Virtual reduction of broken segments on software. Gain occlusion. Design surgical screw holes locating guide. Design the custom-made plates. Print the screw holes locating guide and the custom-made plate.
- Trial name
- NCT05647460
- Testing
- computer guided screw holes locating guide and custom-made plates, conventional plates
- Where
- Egypt
- Volunteers
- 26 people, healthy volunteers welcome
- Sponsor
- Cairo University
Mandible Fracture
Forensic Dental Age Estimation : Validation of Computed Tomography for Third Molar Demirjian's Staging
Age can be estimated in different ways by using skeletal age and dental age. Currently, bone age is determine thanks to the wrist x-rayed, and the dental age using variation in mineralization (Demirjian's score) on the dental…
- Trial name
- SCAO (NCT04907552)
- Where
- France
- Volunteers
- 557 people
- Sponsor
- University Hospital, Montpellier
Mandibular Fractures
Measurement of Mandibular Radio Morphometric Indices in Egyptian Population at Different Ages
this study aims to correlate mandibular indices and different ages in a sample of Egyptian population.
- Trial name
- Indices (NCT03714035)
- Testing
- no intervention
- Where
- Egypt
- Volunteers
- 360 people
- Sponsor
- Cairo University
Mandibular Fractures
Specific Screw Holes Locating Surgical Guide and Pre-bent Plates
The aim of the current study was to evaluate the accuracy of computer-guided mandibular fracture reduction versus the classical work flow
- Trial name
- NCT05444829
- Testing
- specific screw holes locating surgical guide and pre-bent plates, classical reduction and internal fixation.
- Volunteers
- 26 people, healthy volunteers welcome
- Sponsor
- Abdallah Gaber Ali Mohamed
Pediatric Mandibular Fracture
Occlusal Assessment of Pediatric Mandibular Fractures Managed by 3D-Printed Acrylic Occlusal Cap Splint: A Case Series
This study is conducted to evaluate the accuracy of 3D-printed acrylic occlusal cap splint fabricated by computer-guided software in reduction and fixation of pediatric mandibular fractures.
- Trial name
- NCT07515937
- Testing
- 3D-printed occlusal cap splint
- Where
- Egypt
- Volunteers
- 10 people
- Sponsor
- Cairo University
Surgical Wound Infection
Duration of Postoperative Antibiotic Prophylaxis in Facial Fractures
Facial fractures make up a significant proportion of injuries in trauma patients. Treatment of these fractures often results in standard surgical interventions.
- Trial name
- NCT01583062
- Testing
- Amoxicillin/clavulanic acid
- Where
- Switzerland
- Volunteers
- 217 people
- Sponsor
- Insel Gruppe AG, University Hospital Bern
Mandibular Body Fractures
Assessment Polyether Ether Ketone (PEEK) Custom Made Plates Versuscustom Made Titanium Plates in Treatment of Mandibular Body Fractures
The design of the custom made Plates is customized to meet the individual needs of each patient and surgeon. By selecting plate design features, surgeons can customize the plate to create a patient specific solution.
- Trial name
- NCT07729345
- Testing
- computer-assisted Polyether ether ketone (PEEK) custom made plates
- Where
- Egypt
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Cairo University
Displaced Mandibular Angle Fracture
Three Dimensional Versus Standard Miniplate In Fixation Of Mandibular Angle Fracture- A Prospective Randomized Controlled Clinical Trial
The aim of this study is to compare the standard and 3D miniplates fixation in mandibular angle fractures regarding to wound dehiscence, infection, nonunion, pain, hypoesthesia, and malocclusion.
- Trial name
- RCTs (NCT01939015)
- Testing
- 3D titanium miniplate, Standard titanium miniplate- single non compression miniplate
- Where
- Egypt
- Volunteers
- 20 people
- Sponsor
- Cairo University
Mandible Fracture
Comparison of the Post-operative Efficacy of Arch Bar With Single Plate and Two Plate Fixation in Mandibular Parasymphsis Fracture.
This clinical trial is designed to compare post-operative infection, symptoms of paresthesia, inferior border misalignment and operating time of one plate with arch bar against standard two miniplates in mandibular parasymphysis…
- Trial name
- NCT06895174
- Testing
- Titanium miniplates, Arch Bar
- Where
- Pakistan
- Volunteers
- 60 people
- Sponsor
- HITEC-Institute of Medical Sciences
Mandibular Surgery
Bony Overlap Following Use of the Inferior Border Saw for the 'Low and Short' Sagittal Split: A Split-Mouth Study
The purpose of this study is to evaluate if use of an inferior border saw while making the inferior border osteotomy is associated with the medial cortex fracture pattern.
- Trial name
- NCT07104656
- Testing
- Inferior Osteotomy made by border saw, Inferior Osteotomy made with reciprocating saw
- Where
- United States
- Volunteers
- 40 people
- Sponsor
- University of Alabama at Birmingham
Mandibular Fractures
Bone Regeneration With Mesenchymal Stem Cells
Mandible fractures are a common cause of facial injury in adults. The autologous mesenchymal stem cell (AMSC) transplantation, is proposed as an alternative to the conventional graft treatment, improving bone neoformation.The…
- Trial name
- NCT02755922
- Testing
- Application of autologous mesenchymal stem cells
- Volunteers
- 20 people
- Sponsor
- Instituto Mexicano del Seguro Social
Mandibular Fractures, Facial Injuries
Aetiology and Pattern of 122 Patients With Mandibular Condylar Fracture
This retrospective observational study aimed to investigate the aetiology and fracture patterns among patients with mandibular condylar fractures (MCF) who were treated at a trauma center in Shiraz, Iran, between 2018 and 2020.
- Trial name
- NCT07099833
- Testing
- Azita Sadeghzade
- Where
- Iran
- Volunteers
- 122 people, healthy volunteers welcome
- Sponsor
- Azita Sadeghzade
Surgical Complication, Paresthesia
Trial of Bilateral Sagittal Split Osteotomy Induced Paresthesia Using Ultrasonic vs. Reciprocating Saw Instrumentation
The aim of this prospective study is to analyze the postoperative paresthesias experienced in patients who undergo bilateral sagittal split osteotomies (BSSO) using an ultrasonic saw, versus a reciprocating saw.
- Conditions
- Surgical Complication, Paresthesia, Fracture, Nerve Injury
- Trial name
- NCT05205616
- Testing
- Sonopet ultrasonic saw, Reciprocating saw
- Where
- 2 sites in United States
- Volunteers
- 32 people, healthy volunteers welcome
- Sponsor
- University of California, San Francisco
Virtual Plan of Mandibular Fracture
Three-Dimensional Printing and Three-Dimensional Miniplates in Treatment of Anterior Mandibular Fractures
The primary objective of this study was to evaluate the accuracy of virtual reduction and the prebending of the 3D miniplates on printed models for fixation of anterior mandibular fractures.
- Trial name
- NCT06898736
- Testing
- 3d miniplate
- Where
- 3 sites in Egypt
- Volunteers
- 15 people
- Sponsor
- Mansoura University
Mandibular Angle Fracture, Surgical Approach &Amp; Incisions
Efficacy of Transoral Versus Transbuccal Technique for Fixation of Mandibular Angle Fracture
The goal of this clinical trial is to learn if transbuccal technique for mandibular angle fracture is better than transoral technique.
- Trial name
- NCT06622642
- Testing
- Transoral technique for mandibular angle fracture reduction, Transbuccal technique for mandibular angle fracture reduction
- Where
- Pakistan
- Volunteers
- 68 people
- Sponsor
- Services Institute of Medical Sciences, Pakistan
Mandible Fracture
Comparative Study Evaluating Stability of Fracture Segments After Treatment of Mandibular Angle Fracture With 3d Strut Plate With or Without IMMF.
comparative study evaluating stability of fracture segments in mandibular angle fracture with 3d strut plate with or with out post operative IMMF.
- Trial name
- NCT03640039
- Testing
- 3d strut plate.
- Volunteers
- 16 people, healthy volunteers welcome
- Sponsor
- Cairo University