Clinical trials: Pacemaker
Atrial Fibrillation, Tachycardia, Supraventricular
Reducing Episodes by Septal Pacing Efficacy Confirmation Trial (RESPECT)
The purpose of this study is to find out if specialized programs in the AT500 and EnRhythm pacemakers will reduce the number of irregular heartbeat in the upper chamber of the heart and reduce symptoms (such as shortness of…
- Conditions
- Atrial Fibrillation, Tachycardia, Supraventricular, Arrhythmia, Bradycardia
- Trial name
- NCT00289289
- Testing
- Intervention Pacing Features
- Where
- 38 sites in United States, Canada
- Volunteers
- 400 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Magnetic Resonance Imaging, Cardiac Pacemaker, Artificial
Advisa MRI Clinical Study
The purpose of the Advisa MRI System clinical study is to confirm safety and effectiveness in the clinical MRI (Magnetic Resonance Imaging) environment when subjects receive MRI scans up to 2W/kg Specific Absorption Rate (SAR)…
- Trial name
- NCT01110915
- Testing
- Medtronic Advisa MRI Implantable Pulse Generator (IPG), Medtronic CapSureFix MRI™ active fixation MRI lead
- Where
- 37 sites in United States, Australia and 11 more
- Volunteers
- 269 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Congenital Heart Disease, Bradycardia Sinus
Specialized Pacing for Patients With Congenital Heart Disease
The closed-loop stimulation (CLS) algorithm is a novel sensor-based technology that relies on the change in myocardial systolic impedance for modulation of the heart rate during physical and emotional stress.3 The pacing…
- Trial name
- NCT03361189
- Testing
- Closed loop stimulation, Standard rate response
- Where
- United States
- Volunteers
- 4 people
- Sponsor
- University of California, Los Angeles
Analgesia After Pacemaker, AICDS Implantation Pediatrics
Truncal Ultrasound Guided Regional Anesthesia for Implantation and Revision of Automatic Implantable Cardioverter Defibrillators (AICDs) and Pacemakers in Pediatric Patients
The purpose of this study is to determine the efficacy and safety of truncal blocks for pacemaker and Automatic Implantable Cardioverter Defibrillator implantation in children and to prospectively evaluate whether there is a…
- Trial name
- NCT04184349
- Testing
- LA group, B Group
- Where
- United States
- Volunteers
- 19 people
- Sponsor
- The University of Texas Health Science Center, Houston
Cardiac Pacemaker, Artificial, Implantable Cardioverter-Defibrillator
Actions Elicited by In-hospital Follow-up of Cardiac Devices
This study will enroll all patients who will attend an in-hospital follow-up of cardiac device since February 22nd 2010 to June 21st 2010.
- Trial name
- ATHENS (NCT01073449)
- Testing
- In-hospital follow-up of cardiac device
- Where
- 8 sites in Italy
- Volunteers
- 3,362 people
- Sponsor
- Cliniche Humanitas Gavazzeni
Heart Failure
CareLink® Network Evaluation
The purpose of the study is to demonstrate the value of the Medtronic CareLink® Network in clinical practice in the country specific healthcare setting.
- Trial name
- NCT01023022
- Testing
- Medtronic CareLink® Network
- Where
- 10 sites in Poland
- Volunteers
- 176 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Pacemaker Indication
Master Study for the Investigation of Safety and Efficacy of the EVIA Pacemaker
The objective of this study is to prove the safety and efficacy of the EVIA pacemaker. Primarily, the newly implemented Atrial Capture Control algorithm is evaluated, which automatically measures the right atrial threshold and…
- Trial name
- NCT00916344
- Testing
- EVIA Pacemaker
- Where
- France
- Volunteers
- 175 people
- Sponsor
- Biotronik SE & Co. KG
Arrhythmias, Cardiac
Clinically Indicated Magnetic Resonance Imaging in Patients With Cardiac Devices
Patients with implanted cardiac devices who meet appropriate entrance criteria undergo clinically indicated Magnetic Resonance (MR) Imaging Studies using an established safety protocol.
- Trial name
- NCT01130896
- Where
- United States
- Volunteers
- 1,509 people
- Sponsor
- Johns Hopkins University
Adverse Effect of MRI on an Implanted Pacemaker Lead, Adverse Effect of MRI on an Implanted Pacemaker
Safety and Efficacy of the Accent Magnetic Resonance Imaging™ (MRI) Pacemaker and Tendril MRI™ Lead
The MRI Study is a prospective, multi-center, clinical study designed to evaluate the safety and efficacy of the Accent MRI™ System in a patient population indicated for implant of a pacemaker within and outside of the MRI…
- Trial name
- NCT01576016
- Testing
- Accent MRI system (lead safety), Accent MRI system (with MRI scan)
- Where
- 70 sites in United States, Australia and 3 more
- Volunteers
- 950 people
- Sponsor
- Abbott Medical Devices
Bradycardia, Arrhythmia
PREFER (Pacemaker Remote Follow-Up Evaluation and Review)
The purpose of the study is to compare remote pacemaker follow-up to current standard of care follow-up. The study will compare the rate of first diagnosis of clinically actionable events between patients who utilize the…
- Trial name
- NCT00294645
- Testing
- Transtelephonic monitoring (TTM), Medtronic CareLink® Network
- Where
- 45 sites in United States
- Volunteers
- 980 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure