Clinical trials: Amputation; Traumatic, Arm, Upper
Amputation, Amputation, Traumatic
Evaluation of Dexterous Terminal Device
Liberating Technologies, Inc. (LTI) has developed Pointdexter, a dexterous prosthetic fingertip that is integrated into a commercial prosthetic hand and allows for an additional fine grasp.
- Conditions
- Amputation, Amputation, Traumatic, Amputation; Traumatic, Hand, Limb; Absence, Congenital, Upper
- Trial name
- NCT05840601
- Testing
- Pointdexter, Comparator
- Sponsor
- Liberating Technologies, Inc.
Amputation, Amputation, Traumatic
Effects of Myoelectric Channel Count and Targeting for Upper Limb Prosthetic Control
The goal of this clinical trial is to systematically evaluate whether or not two commonly held fundamental assumptions for pattern recognition control translates to functional performance when tested on individuals aged 18 years…
- Conditions
- Amputation, Amputation, Traumatic, Amputation, Congenital, Prosthesis User
- Trial name
- NCT07011420
- Testing
- Experimental socket with 4 untargeted channels active, Experimental socket with 8 untargeted channels active, Experimental socket with up to 16 untargeted channels active
- Where
- 2 sites in United States
- Volunteers
- 32 people
- Sponsor
- Liberating Technologies, Inc.
Amputation, Amputation of Lower Limb
Cryo NerVe Block Extremity AmputatioN RegIStry for Post Operative and pHantom Limb Pain
The goal of this Registry is to see how the device is used when freezing nerves during an amputation procedure.
- Conditions
- Amputation, Amputation of Lower Limb, Amputation of Upper Limb, Amputation, Limb Loss
- Trial name
- VANISH (NCT06908538)
- Testing
- cryoablation
- Where
- 6 sites in United States
- Volunteers
- 2,000 people
- Sponsor
- AtriCure, Inc.
Amputation; Traumatic, Arm, Upper
Teleoperation Experimental Comparison With Able-bodied Subjects
To compare the use of the semi-autonomous control algorithm (condition 1) with the standard of care myoelectric system used with the TASKA prosthetic hand (condition 2).
- Trial name
- NCT05048394
- Testing
- Semi-autonomous myoelectric control algorithm, Standard-of-care myoelectric control algorithm
- Where
- United States
- Volunteers
- 11 people, healthy volunteers welcome
- Sponsor
- Point Designs
Prosthesis User, Congenital Amputation of Upper Limb
Pattern Recognition Prosthetic Control
This study investigates whether simultaneous electromyographic (EMG)-based pattern recognition control of an upper limb prostheses increases wear time among users.
- Conditions
- Prosthesis User, Congenital Amputation of Upper Limb, Amputation; Traumatic, Limb
- Trial name
- Simultaneous (NCT04272593)
- Testing
- EMG-Pattern Recognition Controller
- Where
- United States
- Volunteers
- 8 people
- Sponsor
- Coapt, LLC
Amputation; Traumatic, Arm, Upper, Amputation; Traumatic, Arm: Forearm
Study of the Social and Professional Reintegration Improvements Using a Set of Solutions for Upper Limb Amputation
ORTHOPUS develops assistive technologies to address the lack of availability of medical devices in low and middle income countries.
- Conditions
- Amputation; Traumatic, Arm, Upper, Amputation; Traumatic, Arm: Forearm, Amputation; Traumatic, Hand, at Wrist Level, Wounds and Injuries
- Trial name
- NCT04803253
- Testing
- ORTHOPUS prosthetic accessory: 0109 - Universal Wrist, ORTHOPUS prosthetic terminal device: 0112 - Hook, ORTHOPUS prosthetic terminal device: 0105 - Cosmetic Articulated Hand
- Where
- 3 sites in Nepal
- Volunteers
- 14 people
- Sponsor
- Orthopus
Amputation, Amputation; Traumatic, Hand
Dexterous Partial Hand Prosthesis Outcomes
Liberating Technologies, Inc. (LTI) has developed a dexterous prosthetic fingertip that will be fit onto an i-Digits™ partial hand prosthesis and allow for an additional fine grasp.
- Conditions
- Amputation, Amputation; Traumatic, Hand, Limb; Absence, Congenital, Upper, Prosthesis User
- Trial name
- NCT05038566
- Testing
- Pointdexter
- Where
- 2 sites in United States
- Volunteers
- 4 people, healthy volunteers welcome
- Sponsor
- Liberating Technologies, Inc.
Prosthesis User, Congenital Amputation of Upper Limb
Pattern Recognition Prosthetic Control
Many different factors can degrade the performance of an upper limb prosthesis users control with electromyographic (EMG)-based pattern recognition control.
- Conditions
- Prosthesis User, Congenital Amputation of Upper Limb, Amputation; Traumatic, Limb
- Trial name
- Adaptation (NCT04272489)
- Testing
- EMG-Pattern Recognition Controller
- Where
- United States
- Volunteers
- 9 people
- Sponsor
- Coapt, LLC