Clinical trials: Arrhythmia Ventricular
Persistent Atrial Fibrillation, Ventricular Tachycardia
Advisor HD Grid Observational Study
The aim of this study is to quantify and characterize the outcomes of radiofrequency (RF) ablation after, and the utility of electroanatomical mapping with the Advisor™ HD Grid Mapping Catheter, Sensor Enabled™ (hereafter called…
- Trial name
- NCT03733392
- Testing
- Advisor HD Grid Mapping Catheter, Sensor Enabled
- Where
- 25 sites in Australia, Austria and 9 more
- Volunteers
- 379 people
- Sponsor
- Abbott Medical Devices
Ventricular Tachycardia, Premature Ventricular Contraction
DOACs for Stroke Prevention Post Ventricular Tachycardia Ablation
The purpose of this study is to learn if taking a drug called direct oral anticoagulant after an ablation procedure keeps blood clots from forming and lowers the chance of having a stroke in patients with ventricular tachycardia…
- Conditions
- Ventricular Tachycardia, Premature Ventricular Contraction, Stroke
- Trial name
- STROKE-VT (NCT02666742)
- Testing
- DOAC, Aspirin
- Where
- 5 sites in United States, India
- Volunteers
- 246 people
- Sponsor
- Kansas City Heart Rhythm Institute
Catecholaminergic Polymorphic Ventricular Tachycardia
Flecainide for Catecholaminergic Polymorphic Ventricular Tachycardia
The purpose of this study is to test whether the addition of oral flecainide to standard therapy will reduce ventricular ectopy on exercise test compared to placebo plus standard therapy in patients with Catecholaminergic…
- Trial name
- NCT01117454
- Testing
- Flecainide Acetate, Beta blocker
- Where
- 10 sites in United States
- Volunteers
- 14 people
- Sponsor
- Vanderbilt University Medical Center
Tachycardia, Ventricular Arrythmia
Extravascular ICD Pilot Study
The proposed study is designed to characterize the safety and efficacy of a new extravascular implantable cardioverter defibrillator (ICD) system in humans.
- Trial name
- EV ICD (NCT03608670)
- Testing
- Defibrillation using the Extravascular ICD
- Where
- 4 sites in Australia, New Zealand
- Volunteers
- 26 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Ventricular Tachycardia
Inducibility and Stability of Ventricular Tachycardia Inpatients Undergoing VT Ablation Under General Anesthesia
This research study is being done to see whether general anesthesia (GA) affects our ability to start ventricular tachycardia (VT) during an VT ablation procedure.
- Trial name
- NCT02419547
- Testing
- Versed, Fentanyl, Propofol
- Where
- United States
- Volunteers
- 11 people
- Sponsor
- Brigham and Women's Hospital
Premature Ventricular Contractions, Congestive Heart Failure
Early Elimination of Premature Ventricular Contractions in Heart Failure
Premature ventricular contractions (PVC) are a very common irregular heart beat (arrhythmias) even in patients without heart disease. Frequent PVCs are thought to occur in about 1-4% of the general population.
- Trial name
- EVAC-HF (NCT01757067)
- Testing
- PVC ablation
- Where
- 8 sites in United States, Canada
- Volunteers
- 3 people
- Sponsor
- University of Maryland, Baltimore
Ventricular Outflow Tract Tachycardia
EGM Analysis in Idiopathic Outflow Tract Ventricular Arrhythmia
Investigate the value of unipolar and bipolar electrograms (EGM) for predicting the successful ablation site for idiopathic outflow tract ventricular arrhythmia (OTVA).
- Trial name
- NCT02722577
- Testing
- Radio-frequency Ablation
- Volunteers
- 20 people
- Sponsor
- Abbott Medical Devices
Tachycardia, Ventricular, Catheter Ablation
Continuation of Antiarrhythmics Following Ventricular Tachycardia Catheter Ablation
The investigators aim to study if patients that undergo catheter ablation for ventricular tachycardia benefit from continuation of Vaughan-Williams class III antiarrhythmic drugs for 3 months after their ablation.
- Trial name
- AFTER-VT (NCT04208997)
- Testing
- Antiarrhythmic drug
- Where
- United States
- Volunteers
- 5 people
- Sponsor
- Vanderbilt University Medical Center
Tachycardia, Ventricular Arrythmia
Extravascular ICD Pivotal Study
Pivotal Summary: The study is designed to demonstrate safety and efficacy of the Extravascular Implantable Cardioverter Defibrillator (EV ICD) System.
- Trial name
- EV ICD (NCT04060680)
- Testing
- Defibrillation using the Extravascular ICD
- Where
- 56 sites in United States, Australia and 15 more
- Volunteers
- 393 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Atrial Fibrillation, Heart Failure, Congestive
MINERVA: MINimizE Right Ventricular Pacing to Prevent Atrial Fibrillation and Heart Failure
The aim of this study is to test the impact of the managed ventricular pacing (MVP) mode and atrial preventive and antitachycardia pacing therapies on the reduction of a composite clinical outcome composed of any death, permanent…
- Trial name
- NCT00262119
- Testing
- Pacemaker Medtronic EnRhythm
- Where
- Italy
- Volunteers
- 1,300 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Ventricular Fibrillation, Ventricular Tachycardia
Evaluation of the iD-SystemTM, One-Handed Disposable Internal Defibrillation System.
The main aim is to evaluate the safety and efficacy of the iD-System™, One-handed Disposable Internal Defibrillation System The device is made for manual defibrillation during intra-thoracic procedure, by transferring a shock…
- Trial name
- iD-System (NCT04011631)
- Testing
- Internal defibrillation during cardiac surgery, using the iD-system
- Where
- Belgium
- Volunteers
- 100 people
- Sponsor
- SMART Clinical Products BV
ISCHEMIC CARDIOMYOPATHY
Clinical Trial of Manganese-Enhanced MRI (MEMRI) to Assess Peri-Infarct Injury
The purpose of this study is to evaluate the safety and tolerance of a new intravenous diagnostic agent, SeeMore or EVP 1001-1, in patients with Cardiovascular Disease (MEMRI scan).
- Trial name
- NCT02933034
- Testing
- Manganese-enhanced MRI contrast reagent, Gadolinium-enhanced MRI contrast reagent
- Where
- United States
- Volunteers
- 33 people
- Sponsor
- Stanford University
Ventricular Tachycardia, Atrial Fibrillation
AVAI: Atrial Ventricular Arrythmia Incidence
The purpose of this observational study is to collect data regarding the population of patients implanted with St. Jude Medical ICD.
- Trial name
- AVAI (NCT00832975)
- Where
- 2 sites in Spain
- Volunteers
- 157 people
- Sponsor
- Abbott Medical Devices
Cardiac Arrest
Amiodarone, Lidocaine or Neither for Out-Of-Hospital Cardiac Arrest Due to Ventricular Fibrillation or Tachycardia
The primary objective of the trial is to determine if survival to hospital discharge is improved with early therapeutic administration of a new Captisol-Enabled formulation of IV amiodarone (Nexterone-PM101) compared to placebo.
- Trial name
- ALPS (NCT01401647)
- Testing
- amiodarone, Lidocaine, Normal saline
- Where
- 9 sites in United States, Canada
- Volunteers
- 3,024 people
- Sponsor
- University of Washington
Sudden Cardiac Death, Sudden Cardiac Arrest
Wearable Cardioverter Defibrillator in Hemodialysis Patients (WED-HED) Study
A multi-center, prospective, randomized controlled clinical trial with 1:1 assignment of treatment and control. This study will evaluate the impact of wearable cardioverter defibrillator use on sudden cardiac death in incident…
- Trial name
- WED-HED (NCT02481206)
- Testing
- Wearable Cardioverter Defibrillator
- Where
- 31 sites in United States
- Volunteers
- 66 people
- Sponsor
- Zoll Medical Corporation
Mitral Valve Insufficiency, Atrial Fibrillation
Left Atrial Distensibility to Predict Left Ventricular Filling Pressure and Prognosis in Patients With Severe Mitral Regurgitation
A large left atrial (LA) volume, which represents chronic diastolic dysfunction, is associated with a poor outcome, regardless of systolic function.
- Conditions
- Mitral Valve Insufficiency, Atrial Fibrillation, Heart Failure
- Trial name
- NCT01172184
- Testing
- Cardiac catheterization
- Where
- Taiwan
- Volunteers
- 111 people, healthy volunteers welcome
- Sponsor
- Kaohsiung Veterans General Hospital.
Death, Sudden, Cardiac, Ventricular Fibrillation
Automatic External Defibrillation Monitoring in Cardiac Arrest
We propose to randomize automatic external cardioverter/defibrillators (AECD) in patients who are at high risk for life-threatening abnormal heart rhythms (arrhythmias) and are admitted to the telemetry ward, all other treatments…
- Conditions
- Death, Sudden, Cardiac, Ventricular Fibrillation, Tachycardia, Ventricular
- Trial name
- NCT00382928
- Testing
- Defibrillation of pulseless VT/VF by AECD
- Where
- United States
- Volunteers
- 192 people
- Sponsor
- Foundation for Atlanta Veterans Education and Research, Inc.
Ventricular Tachycardia
Bipolar Ventricular Tachycardia (VT) Study
This non-randomized study will examine the safety and efficacy of irrigated bipolar radiofrequency (RF) ablation in the treatment of ventricular tachycardia (VT) in patients for whom standard VT unipolar RF ablation has been…
- Trial name
- NCT02374476
- Testing
- Bipolar Ablation
- Where
- 6 sites in United States
- Volunteers
- 145 people
- Sponsor
- Srinivas Dukkipati
Ventricular Tachycardia, Cardiomyopathy
Phase I/II Study of EP-guided Noninvasive Cardiac Radioablation for Treatment of Ventricular Tachycardia
Phase I/II Study of EP-guided Noninvasive Cardiac Radioablation (ENCORE) for Treatment of Ventricular Tachycardia
- Conditions
- Ventricular Tachycardia, Cardiomyopathy, Premature Ventricular Contractions
- Trial name
- ENCORE-VT (NCT02919618)
- Testing
- stereotactic body radiotherapy (SBRT)
- Where
- United States
- Volunteers
- 19 people
- Sponsor
- Washington University School of Medicine
Bradycardia, Sinus Node Dysfunction
Physiologic Pacing Registry
The Physiologic Pacing Registry is a prospective, observational, multi-center registry performed to gain a broader understanding of 1) physiologic pacing implant and follow-up workflows, including pacing and sensing measurements…
- Conditions
- Bradycardia, Sinus Node Dysfunction, Heart Block, Syncope
- Trial name
- NCT03719040
- Testing
- Physiologic pacing device implant
- Where
- 50 sites in United States, Australia and 14 more
- Volunteers
- 870 people
- Sponsor
- Abbott Medical Devices