Clinical trials: Arrythmia, Cardiac
Atrial Premature Beats
To Evaluate the Efficacy and Safety of Wenxin Keli in Treating Atrial Premature Beats
A randomized, double-blind, two dose group, parallel-control multi-center, post-marketing clinical trial,to evaluate the efficacy and safety of Wenxin keli in treating atrial premature beats by different dose,to provide a…
- Trial name
- NCT02319603
- Testing
- Low dose WenXin keli, High dose WenXin keli
- Where
- China
- Volunteers
- 288 people
- Sponsor
- Beijing Bozhiyin T&S Co., Ltd.
Tachycardia
RIGHT: Rhythm ID Going Head-to-Head Trial
RIGHT is a randomized, prospective, two-arm study that will assess the differential efficacy of VITALITY 2 implantable cardioverter defibrillators (ICDs) using Rhythm ID™ versus selected Medtronic ICDs.
- Trial name
- NCT00148954
- Testing
- VITALITY 2 Implantable Cardioverter Defibrillator, Medtronic Implantable Cardioverter Defibrillator
- Where
- United States
- Volunteers
- 1,962 people
- Sponsor
- Boston Scientific Corporation
Left Ventricular Dysfunction, Ventricular Dysfunction
Low Ejection Fraction in Single Lead ECG- Ochsner
The purpose of this research is to prospectively test and validate the single-lead Low EF algorithm in outpatients in order to test the performance of a single-lead ECG based algorithm to identify people with decreased left…
- Conditions
- Left Ventricular Dysfunction, Ventricular Dysfunction, Heart Diseases, Cardiovascular Diseases
- Trial name
- NCT05010642
- Testing
- Use of Eko DUO electronic Stethoscope
- Where
- United States
- Volunteers
- 307 people, healthy volunteers welcome
- Sponsor
- Eko Devices, Inc.
Ventricular Fibrillation, Ventricular Tachycardia
Further Acute Research of a Subcutaneous Implantable Defibrillator (S-ICD) System
The purpose is to further evaluate the operation, safety, and feasibility of a subcutaneous implantable defibrillator (S-ICD) system in patients who require an implantable cardioverter defibrillator (ICD)for treating ventricular…
- Trial name
- NCT00399217
- Testing
- Subcutaneous Implantable Defibrillator (S-ICD) system, ICD
- Where
- United Kingdom
- Volunteers
- 55 people
- Sponsor
- Boston Scientific Corporation
Arrhythmia
Clinical Performance Evaluation of the Hativ P30
Hativ P30 is intended to record, store, and transfer one-and two-channel ECG rhythms, and analyze them based on an artificial intelligence (AI) algorithm. In single channel mode, Hativ P30 can record lead-I.
- Trial name
- NCT06713226
- Testing
- Hativ P30 and 12-lead ECG comparator device
- Volunteers
- healthy volunteers welcome
- Sponsor
- VUNO Inc.
Atrial Fibrillation
Tracking Results of Ablations to Combat AF Registry Generation 2
The primary objective of the TRAC-AF Registry is to capture real-world safety and effectiveness data on AtriCure devices used to conduct open concomitant and/or hybrid ablation, and management of the LAA concomitant to a cardiac…
- Trial name
- TRAC-AF (NCT05111015)
- Testing
- Open Concomitant Surgical Ablation Procedures, Hybrid (Convergent) Ablation Procedures, AtriCure Hybrid Totally Thoracoscopic Ablation Procedures
- Where
- 29 sites in United States, Austria and 1 more
- Volunteers
- 10,000 people
- Sponsor
- AtriCure, Inc.
Alzheimer's Disease
A Cardiac Safety Study of Galantamine in the Treatment of Alzheimer's Disease.
The objective of this trial was to investigate the effect of galantamine (an acetylcholinesterase inhibitor) on heart rate and PR interval (the time it takes for the heart's electrical impulse to get from the atria to the…
- Trial name
- NCT00309725
- Testing
- galantamine
- Volunteers
- 139 people
- Sponsor
- Johnson & Johnson Pharmaceutical Research & Development, L.L.C.
Paroxysmal Atrial Fibrillation
BEAT AF - Braking Ectopic Atrial Trends In Atrial Fibrillation
Paroxysmal AF subjects with a documented ECG event of AF will be recruited to the study To assess the efficacy of CardiaCare™ RR2 wearable home-care neuromodulation system in reducing AF burden and symptoms in Paroxysmal AF…
- Trial name
- NCT05872776
- Testing
- Neuromodulation with RR2 device
- Where
- 2 sites in Israel
- Volunteers
- 50 people
- Sponsor
- Ziv HealthCare Ltd.
Paroxysmal Atrial Fibrillation
A Study of the Safety and Efficacy of the VytronUS Low-Intensity Collimated Ultrasound Ablation System
The objective of this investigation is to evaluate whether pulmonary vein isolation using the VytronUS ablation system is safe and effective acutely and at 3 months.
- Trial name
- NCT01900678
- Testing
- VytronUS Ablation System
- Where
- Czechia
- Volunteers
- 7 people
- Sponsor
- VytronUS, Inc.
Cardiomyopathies, Cardiac Arrest
AI-powered ECG Analysis Using Willem™ Software in High-risk Cardiac Patients (WILLEM)
WILLEM is a multi-center, prospective and retrospective cohort study. The study will assess the performance of a cloud-based and AI-powered ECG analysis platform, named Willem™, developed to detect arrhythmias and other abnormal…
- Conditions
- Cardiomyopathies, Cardiac Arrest, Cardiac Arrhythmias, Sudden Cardiac Death
- Trial name
- WILLEM (NCT05890716)
- Testing
- AI-powered ECG analysis to detect cardiac arrhythmic episodes
- Where
- 13 sites in Netherlands, Spain
- Volunteers
- 5,342 people, healthy volunteers welcome
- Sponsor
- Idoven 1903 S.L.
Bradycardia
SCANCAP Scandinavian Automatic Capture Study
The primary objective of this study is to document the success rate of the automatic threshold testat pre-discharge in a normal pacemaker patient population implanted with Guidant Insignia Ultra or AVT .
- Trial name
- NCT00180609
- Testing
- Automatic threshold test in Insignia Pacemakers from Guidant
- Where
- Denmark
- Volunteers
- 203 people
- Sponsor
- Guidant Corporation
Atrial Fibrillation
Explore the Efficacy and Safety of Once-daily Oral Rivaroxaban for the Prevention of Cardiovascular Events in Subjects With Nonvalvular Atrial Fibrillation Scheduled for Cardioversion
A study for patients with abnormal heart rhythm (atrial fibrillation) who need to undergo cardioversion (procedure to restore normal heart rhythm).
- Trial name
- X-VERT (NCT01674647)
- Testing
- Rivaroxaban (Xarelto, BAY59-7939), Vitamin K antagonist (VKA)
- Where
- 178 sites in United States, Belgium and 15 more
- Volunteers
- 1,504 people
- Sponsor
- Bayer
Atrial Fibrillation
Post-Marketing Surveillance of Prazaxa® on the Long-term Use in Patients With Nonvalvular Atrial Fibrillation
To investigate the safety and efficacy of long-term use of Prazaxa® Capsules in patients with nonvalvular atrial fibrillation for preventing the occurrence of ischemic stroke or systemic embolism (SEE).
- Trial name
- NCT01491178
- Testing
- Prazaxa
- Where
- 1,164 sites in Japan
- Volunteers
- 6,772 people
- Sponsor
- Boehringer Ingelheim
Atrial Fibrillation
A Study Comparing Vernakalant Therapy to Amiodarone Therapy in Acute Management of Recent Onset Atrial Fibrillation (AF) (MK-6621-055)
This study will compare vernakalant therapy to amiodarone therapy in the acute management of recent onset atrial fibrillation.
- Trial name
- NCT01627106
- Testing
- Vernakalant, Amiodarone
- Sponsor
- Advanz Pharma
Bradycardia, Right Ventricular Pacing
Left Bundle Branch Area Pacing (LBBAP) PMCF Study
The objective of this study is to evaluate the safety and effectiveness of LBBA pacing/sensing in patients implanted with the Tendril STS 2088TC or UltiPace LPA1231 lead through 6 months post-implant.
- Conditions
- Bradycardia, Right Ventricular Pacing, Heart Failure, Atrial Fibrillation (AF)
- Trial name
- LBBAP PMCF (NCT07217392)
- Testing
- LBBAP lead
- Where
- 15 sites in Brazil, France and 7 more
- Volunteers
- 200 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation
MODULA Modul 7 VRR
This study will look at the correlation between ventricular rate regulation (VRR) and the percentage of biventricular pacing as well as subjective quality of life and level of physical ability in CRT patients with atrial…
- Trial name
- NCT00180414
- Testing
- CRT devices with ventricular rate regulation [VRR] (CE labeled)
- Where
- Germany
- Volunteers
- 8 people
- Sponsor
- Boston Scientific Corporation
Atrial Fibrillation
Pivotal Clinical Study of Endoscopic Ablation for Atrial Fibrillation (AF) in Patients That Have Failed Drugs
The purpose of the study is to compare two types of treatment for atrial fibrillation (AF) that are designed to treat the symptoms of atrial fibrillation.
- Trial name
- ENABLE (NCT00477230)
- Testing
- Endoscopic Ablation System, Standard Anti-arrhythmic Drug (AAD) Therapy
- Where
- 18 sites in United States
- Volunteers
- 64 people
- Sponsor
- CardioFocus
Arrhythmias, Cardiac
EASYER (EpiAccess SYstem Registry) A Post Market Observational Registry
The objective of the Registry is to provide post market clinical outcome and potential health economics data and confirm the continued safety of the EpiAccess system.
- Trial name
- EASYER (NCT02481102)
- Where
- 3 sites in United States
- Volunteers
- 36 people
- Sponsor
- EpiEP, Inc.
Tachyarrhythmia
Magnetic Resonance (MR) Conditional Tachyarrhythmia Therapy Products Post-approval Study
Following product approval, further confirmation of the MR Conditional Tachyarrhythmia Therapy Systems sensing and detection performance post MRI exposure will be obtained by actively monitoring de-identified device data obtained…
- Trial name
- NCT02849769
- Testing
- Implant of an MR-conditional Tachy device system
- Volunteers
- 10,979 people
- Sponsor
- Medtronic
Atrial Fibrillation, Paroxysmal Atrial Fibrillation
FIRE AND ICE Re-Ablations (Retrospective Data Collection)
Retrospective data collection on re-ablations performed within the FIRE AND ICE Trial.
- Trial name
- Re-Do (NCT03314753)
- Testing
- No interventions - retrospective data collection
- Where
- 13 sites in Czechia, France and 4 more
- Volunteers
- 89 people
- Sponsor
- Medtronic Cardiac Ablation Solutions
The first 1,020 results can be paged through. Add a filter or change the sort order to reach the rest.