Clinical trials: Arthroplasty, Hip, Replacement
Arthroplasties, Hip Replacement
REDAPT Retrospective-Prospective Modular Stem Study
A Retrospective-Prospective Study of REDAPT Revision Femoral System Modular Stem is a post-market, retrospective-prospective, multi-center, single arm, consecutive series study design to provide data on the post market…
- Trial name
- NCT02661620
- Testing
- REDAPT Revision Femoral System modular stem
- Where
- 5 sites in United States, Belgium and 1 more
- Volunteers
- 140 people
- Sponsor
- Smith & Nephew, Inc.
Non-inflammatory Degenerative Joint Disease
Multi-Center Comparative Trial of the ASR™-XL Acetabular Cup System vs. the Pinnacle™ Metal- on- Metal Total Hip System
The primary objective of this investigation is to evaluate the clinical and radiographic outcomes of the ASR™-XL Acetabular Cup System compared to the Pinnacle™ Acetabular Cup with a 28mm or 36mm ULTAMET™ metal insert.
- Trial name
- ASR (NCT00561600)
- Testing
- ASR™-XL Modular Acetabular Cup System, Pinnacle™ acetabular shell
- Where
- 8 sites in United States
- Volunteers
- 265 people
- Sponsor
- DePuy Orthopaedics
Arthroplasty, Replacement, Hip
A Post Market Clinical Follow-up Study With the aneXys Cup
The purpose of the study is the evaluation of the clinical and radiological short- to long-term safety and performance of the aneXys cup. The data will be used for an ongoing evaluation of the product safety and performance.
- Trial name
- NCT03274830
- Testing
- aneXys
- Where
- 3 sites in Germany
- Volunteers
- 102 people
- Sponsor
- Mathys Ltd Bettlach
Non-inflammatory Degenerative Joint Disease, Osteoarthritis
Ceramic On Ceramic (COC) 36mm PAS IDE Rollover Subjects; Ceramic Acetabular Bearing With Ceramic Femoral Head in Total Hip Replacement
This study is intended to gather medium (5- to 7-years) and long-term (minimum 8- to 10-years) information regarding the performance and safety of the commercially available 36mm CERAMAX® Ceramic on Ceramic (COC) Total Hip System…
- Conditions
- Non-inflammatory Degenerative Joint Disease, Osteoarthritis, Avascular Necrosis, Post-Traumatic Osteoarthritis of Hip
- Trial name
- COC36mmPAS (NCT02096198)
- Where
- 5 sites in United States
- Volunteers
- 81 people
- Sponsor
- DePuy Orthopaedics
Deep Vein Thrombosis of Lower Limb, Pulmonary Embolism (PE)
Deep Vein Thrombosis (DVT) Prevention in Total Hip Arthroplasty: Continuous Enhanced Circulation Therapy (CECT) Versus Low Molecular Weight Heparin (LMWH)
Evaluation of the safety and effectiveness of ActiveCare+ CECT device +/- baby dose aspirin (81 mg QD) for lowering the potential risk for bleeding and of DVT during and after THA surgery in comparison with LMWH.
- Conditions
- Deep Vein Thrombosis of Lower Limb, Pulmonary Embolism (PE), Bleeding
- Trial name
- SAFE (NCT00358735)
- Testing
- ActiveCare CECT device, Enoxaparin
- Where
- 9 sites in United States
- Volunteers
- 411 people
- Sponsor
- Medical Compression Systems
Hip Osteoarthritis
OXINIUM◊ DH Total Hip Arthroplasty Pivotal Study
The purpose of this study is to monitor safety of the participants implanted with the OXINIUM◊ DH Hip System up to 10-years post-implantation
- Trial name
- NCT02353377
- Testing
- OXINIUM DH Hip System, BIOLOX◊
- Volunteers
- 413 people
- Sponsor
- Smith & Nephew, Inc.
Hip Replacement
Hip Arthroplasty With Logica Mirror Femoral Stem
Logica Mirror femoral stem is a CE marked medical device, and within this clinical trial it is used according to its intended use.
- Trial name
- NCT05003739
- Testing
- Hip arthroplasty with Logica Mirror femoral stem
- Where
- Czechia
- Volunteers
- 47 people
- Sponsor
- Limacorporate S.p.a
Degenerative Joint Disease, Osteoarthritis, Hip
Safety and Effectiveness of the HIT Reverse HRS
The purpose of this study is to determine if the use of the HIT Reverse Hip Replacement System is safe and effective in patients undergoing total hip replacement.
- Conditions
- Degenerative Joint Disease, Osteoarthritis, Hip, Avascular Necrosis of Hip, Traumatic Arthropathy-Hip
- Trial name
- NCT05357378
- Testing
- Hip Innovation Technology Reverse Hip Replacement System, Already-marketed semi-constrained uncemented hip systems using a metal-on-XLPE or ceramic-on-XLPE bearing combination.
- Where
- 6 sites in United States
- Volunteers
- 288 people
- Sponsor
- Hip Innovation Technology
Osteoarthritis
Clinical Study on BiHapro Total Hip System With Different Surface Coatings
This post market study intends to evaluate the safety and the performance of BiHapro Total Hip System with two types of coatings.
- Trial name
- NCT00755001
- Testing
- BiHapro hip stem with PPS Ti+Plasma HA, BiHapro hip stem with PPS Ti+BoneMaster HA
- Where
- 2 sites in Spain
- Volunteers
- 40 people
- Sponsor
- Zimmer Biomet
Osteoarthritis (OA) of the Hip
TED Stocking vs. Reparel Garment After Hip Replacement
This randomized, prospective study compares the effectiveness of a novel bioactive garment (Reparel Leg Sleeve) versus standard TED compression stockings in reducing postoperative leg swelling, pain, and deep vein thrombosis…
- Trial name
- NCT07246200
- Testing
- Reparel Bioactive Sleeve, TED Stocking
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- Reparel
Arthroplasty
Efficacy and Safety Study of 4975 in Patients Undergoing Total Hip Replacement
Evaluate the efficacy, safety and tolerability of a single intraoperative dose of 4975 in patients undergoing total hip replacement
- Trial name
- NCT00683267
- Testing
- 4975, highly purified capsaicin
- Where
- 10 sites in United States
- Volunteers
- 118 people
- Sponsor
- Anesiva, Inc.
Hip Arthroplasty Replacement
Follow up Study of Patients Undergoing Total Hip Arthroplasty CERAFIT® Grafted With Poly Sodium Styrene Sulfonate
The risk of infection after primary Total Hip Arthroplasties (THA)is generally estimated to be less than 1% but remains a severe and costly complication, source of morbidity and even mortality.
- Trial name
- NCT01454271
- Testing
- Total Hip Arthroplasty Replacement
- Where
- France
- Sponsor
- Societe ACTIVBIOMAT
Non-inflammatory Degenerative Joint Disease
36 mm Ceramic-on-Ceramic Acetabular Cup Total Hip Replacement
This study is a supplement to the 28 mm Ceramic-on-Ceramic study which was designed to evaluate artificial hips with a 28 mm ceramic head and liner to determine whether they perform as well as artificial hips with a 28 mm ceramic…
- Trial name
- NCT00953719
- Testing
- 36 mm ceramic head on a ceramic acetabular liner, 28 mm ceramic head on a polyethylene acetabular liner
- Where
- 5 sites in United States
- Volunteers
- 243 people
- Sponsor
- DePuy Orthopaedics
Total Hip Replacement
Post-Market Observational Study of the HARMONY® Evolution Implants and Instruments
The purpose of this study is to evaluate the safety and performance of the HARMONY® Evolution implants in a series of operated subjects treated in THR.
- Trial name
- NCT06628336
- Testing
- HARMONY EVOLUTION
- Where
- 5 sites in France
- Volunteers
- 264 people
- Sponsor
- Symbios Orthopedie SA
Arthroplasty, Replacement, Hip
Total Hip Replacement Study With XRP4563 (Enoxaparin Sodium)
This study is performed to confirm the optimal dose for THR (total hip replacement).
- Trial name
- NCT00349180
- Testing
- Enoxaparin sodium
- Where
- Japan
- Volunteers
- 156 people
- Sponsor
- Sanofi
Surgical Wound
A Post-Market Clinical Investigation on Mepilex Border Post-Op
This is a retrospective, observational (non-interventional), single-arm, single-centre, post-market clinical investigation designed to verify clinical performance and safety of Mepilex Border Post-Op when used according to…
- Trial name
- ARCTIS (NCT04994145)
- Where
- Belgium
- Volunteers
- 560 people
- Sponsor
- Molnlycke Health Care AB
Hip Disease
ACE Acetabular Cup Spanish PMCF Study
A total hip replacement is one of the most successful and cost-effective surgical procedures in orthopaedics, involving the replacement of both the hip ball and socket.
- Trial name
- NCT07115732
- Testing
- Total Hip Replacement
- Where
- Spain
- Volunteers
- 120 people
- Sponsor
- JRI Orthopaedics
Osteoarthritis, Rheumatoid Arthritis
Clinical Study Comparing Two Implant Surface Finishes in Patients Undergoing Cementless Total Hip Replacement
Prospective, randomized study of Summit Porocoat versus Summit DuoFix HA in total hip arthroplasty
- Conditions
- Osteoarthritis, Rheumatoid Arthritis, Post-traumatic Arthritis, Avascular Necrosis
- Trial name
- SPD (NCT00306917)
- Testing
- non-coated femoral hip stem, coated femoral hip stem
- Where
- United States
- Volunteers
- 245 people
- Sponsor
- DePuy Orthopaedics
Osteoporosis
Bone Histomorphometry in Postmenopausal Men and Women With Osteoarthritis Undergoing Total Hip Replacement
The primary objective of this study is to determine the incidence of modeling-based bone formation in the femoral neck in participants who have received denosumab and are undergoing total hip replacement (THR).
- Trial name
- NCT02576652
- Testing
- Tetracycline, Demeclocycline, Total Hip Replacement
- Where
- 2 sites in United States
- Volunteers
- 6 people
- Sponsor
- Amgen
Rheumatoid Arthritis, Osteoarthritis
A Multi-centre Study to Assess the Long-term Performance of the Summit™ Hip in Primary Total Hip Replacement
The purpose of this study is to monitor the performance of the Summit™ hip in the treatment of patients with hip joint disease requiring a total hip replacement.
- Conditions
- Rheumatoid Arthritis, Osteoarthritis, Post-traumatic Arthritis, Collagen Disorders
- Trial name
- NCT00208390
- Testing
- Summit Tapered Hip System
- Where
- 5 sites in China, Hong Kong and 3 more
- Volunteers
- 275 people
- Sponsor
- DePuy International