Clinical trials: Block, Heart
Aortic Valve Calcification, Aortic Valve Stenosis
VALVOSOFT® Pivotal Study
The objective of the study is to evaluate the safety and performance of a new non-invasive ultrasound therapy (NIUT) with Valvosoft in the treatment of Calified Aortic Stenosis
- Trial name
- NCT05235568
- Testing
- VALVOSFT intervention
- Where
- 11 sites in France, Germany and 1 more
- Volunteers
- 60 people
- Sponsor
- Cardiawave SA
Heart Failure, Left Bundle-Branch Block
LV Only MPP With SyncAV
The objective of this clinical investigation is to evaluate the clinical benefits of left ventricle (LV) only pacing combined with automatic adjustment of AV timing (SyncAV) in patients receiving cardiac resynchronization therapy…
- Trial name
- NCT03567096
- Testing
- BiV pacing with MPP and SyncAV, LV only pacing with MPP and SyncAV
- Where
- 6 sites in Canada, France and 2 more
- Volunteers
- 101 people
- Sponsor
- Abbott Medical Devices
Symptomatic Severe Aortic Stenosis
Portico Next Generation Approval Study
The purpose of this clinical study is to evaluate the acute safety and effectiveness of the next-generation Navitor (Portico™ NG) Transcatheter Aortic Heart Valve as assessed by the rate of all-cause mortality at 30 days and the…
- Trial name
- NCT04011722
- Testing
- Portico™ NG (Navitor) Valve and FlexNav™ Delivery System, Navitor Titan Valve (35mm) Valve and Large FlexNav™ Delivery System
- Where
- 28 sites in United States, Australia and 3 more
- Volunteers
- 333 people
- Sponsor
- Abbott Medical Devices
Cardiac Pacemaker, Arrythmia
Aveir VR Real-World Evidence Post-Approval Study
The purpose of this post-approval study is to evaluate the long-term safety of the single-chamber Aveir VR leadless pacemaker using real-world evidence methods.
- Conditions
- Cardiac Pacemaker, Arrythmia, Bradycardia
- Trial name
- NCT05270499
- Testing
- Aveir VR Leadless Pacemaker System
- Where
- United States
- Volunteers
- 3,427 people
- Sponsor
- Abbott Medical Devices
Aortic Valve Insufficiency, Regurgitation, Aortic Valve
Aortic Valve Replacement With Trifecta(TM)
The purpose of this study is to confirm the clinical safety and effectiveness of the Trifecta valve.
- Conditions
- Aortic Valve Insufficiency, Regurgitation, Aortic Valve, Aortic Valve Incompetence, Aortic Valve Stenosis
- Trial name
- NCT00475267
- Testing
- Trifecta aortic heart valve
- Where
- 5 sites in Canada
- Volunteers
- 203 people
- Sponsor
- Abbott Medical Devices
Familial Hypercholesterolemia - Heterozygous
Study to Evaluate Efficacy and Safety of Inclisiran in Children With Heterozygous Familial Hypercholesterolemia
This is a pivotal phase III study designed to evaluate safety, tolerability, and efficacy of inclisiran in children (aged 6 to <12 years) with heterozygous familial hypercholesterolemia (HeFH) and elevated low density lipoprotein…
- Trial name
- ORION-20 (NCT06597019)
- Testing
- Inclisiran
- Where
- 66 sites in United States, Argentina and 21 more
- Volunteers
- 60 people
- Sponsor
- Novartis Pharmaceuticals
Coronary Occlusion
Single-Arm Study Evaluating Use of the CORA Catheters for the Crossing of Coronary Chronic Total Occlusions
The goal of this clinical trial is to evaluate the safety and effectiveness of the coraFlex, coraForce, and coraCross catheters for crossing chronic total occlusions of the coronary arteries.
- Trial name
- Cora CTO (NCT05848232)
- Testing
- coraFlex Catheter, coraForce Catheter, coraCross Catheter
- Where
- United States
- Volunteers
- 150 people
- Sponsor
- ReFlow Medical, Inc.
Severe Aortic Valve Stenosis
The PROTEMBO Trial
The goal of this prospective, multi-center, randomized, controlled study is to compare the safety and efficacy of the ProtEmbo Cerebral Embolic Protection device to a hybrid control (no embolic protection device ('No Device') and…
- Trial name
- NCT05873816
- Testing
- ProtEmbo - Cerebral Embolic Protection, Sentinel - Cerebral Embolic Protection
- Where
- 20 sites in United States, Germany and 1 more
- Volunteers
- 284 people
- Sponsor
- Protembis GmbH
Aortic Valve Stenosis
Valvosoft First-In-Human Study in Severe Symptomatic Aortic Stenosis
This is a prospective, controlled, single-arm clinical investigation for the treatment of subjects with severe symptomatic aortic valve stenosis using Valvosoft® Pulsed Cavitational Ultrasound Therapy (PCUT) - First-In-Human
- Trial name
- NCT04665596
- Testing
- Ultrasound treatment
- Where
- Serbia
- Volunteers
- 10 people
- Sponsor
- Cardiawave SA
Coronary Vessel Occlusion
Study of the CAT RX Aspiration Catheter When Used in Patients With Large Occlusive Thrombus in Coronary Arteries
The objective of this study is to demonstrate the safety and performance of the Indigo Aspiration System using the CAT RX aspiration catheter in a population presenting with acute high thrombus burden coronary vessel occlusion…
- Trial name
- NCT03957473
- Testing
- Indigo Aspiration System
- Where
- 25 sites in United States
- Volunteers
- 400 people
- Sponsor
- Penumbra Inc.
Severe Aortic Stenosis
Safety & Efficacy Study of the Medtronic CoreValve® System-Treatment of Symptomatic Severe Aortic Stenosis With Significant Comorbidities in Extreme Risk Subjects Who Need Aortic Valve Replacement
To evaluate the safety and efficacy of the Medtronic CoreValve® System for the treatment of symptomatic severe aortic stenosis in subjects with significant comorbidities in whom the risk of surgical aortic valve replacement has a…
- Trial name
- NCT01675440
- Testing
- Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI)
- Where
- 43 sites in United States
- Volunteers
- 782 people
- Sponsor
- Medtronic Cardiovascular
Severe Aortic Stenosis
Navitor Japan Study
The Navitor Japan Study is designed to evaluate the safety and performance of the Navitor™ valve used in combination with the FlexNav™ delivery system in a contemporary, real-world setting.
- Trial name
- NCT07193888
- Testing
- Navitor Transcatheter Aortic Valve Implantation
- Where
- 3 sites in Japan
- Volunteers
- 100 people
- Sponsor
- Abbott Medical Devices
Aortic Valve Stenosis
VitaFlow LIBERTY Europe
This is a prospective, single-arm, multi-center, observational, post-market clinical investigation to document the clinical safety and performance of MicroPort CardioFlow VitaFlow Liberty™ Transcatheter Aortic Valve System in the…
- Trial name
- NCT06535659
- Testing
- VitaFlow Liberty™ Transcatheter Aortic Valve System
- Where
- 9 sites in Ireland, Italy and 3 more
- Volunteers
- 222 people
- Sponsor
- Shanghai MicroPort CardioFlow Medtech Co., Ltd.
Heart Failure, Chronic Heart Failure
Wearable Tissue Oximetry During Arm Cuff Occlusion, Walking, and Standing Tests in Outpatients With Chronic Heart Failure
This prospective, single-center, observational pilot study evaluated an investigational wearable tissue oximeter (NIRSense Argus Oximetry System, also called Envello Core) in adult outpatients with chronic heart failure in New…
- Trial name
- NCT07874386
- Testing
- Argus Oximetry System
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- NIRSense Inc.
Aortic Stenosis
Self-Centering Guide Catheter Feasibility Study
An evaluation of the feasibility of using the Self-Centering Guide Catheter to deliver a guide wire across a stenotic native aortic valve into the left ventricle.
- Trial name
- NCT02639494
- Testing
- Self-Centering Guide Catheter
- Where
- United States
- Volunteers
- 20 people
- Sponsor
- Boston Scientific Corporation
Aortic Stenosis
CHANGE Neo™ TA Registry With ACURATE Neo™ Aortic Bioprosthesis and ACURATE Neo™ TA Transapical Delivery System
The purpose of this registry is to collect specific health and patient data to identify more precisely the patient population undergoing TA aortic valve replacement with the ACURATE neo™ Aortic biprosthesis and ACURATE neo™ TA…
- Trial name
- NCT03454360
- Testing
- ACURATE neo™ Aortic Bioprosthesis
- Where
- 10 sites in Germany
- Volunteers
- 107 people
- Sponsor
- Symetis SA
Aortic Valve Stenosis, Heart Valve Diseases
First in Man Study of the JenaValve TAVI Plus System Transfemoral
The objective of this study is to evaluate feasibility, safety and effectiveness of the first generation transfemoral JenaValve Pericardial TAVR System (formerly named JenaValve TAVI Plus System- Transfemoral) in an elderly…
- Conditions
- Aortic Valve Stenosis, Heart Valve Diseases, Heart Diseases, Cardiovascular Diseases
- Trial name
- CP-0001 (NCT02818959)
- Testing
- JenaValve Pericardial TAVR System
- Where
- 2 sites in Germany
- Volunteers
- 7 people
- Sponsor
- JenaValve Technology, Inc.
Aortic Valve Stenosis
Assessment of the St Jude Medical Portico Resheathable Aortic Valve System-Alternative Access
Expand the indication of the Portico TF Delivery System and obtain approval of the Alternative Access Delivery System
- Trial name
- Portico ALT (NCT03056573)
- Testing
- Transaortic TAVR Implant, Subclavian /Axillary TAVR implant
- Where
- 10 sites in Denmark, Germany and 3 more
- Volunteers
- 64 people, healthy volunteers welcome
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation
Safety and Effectiveness of Left Atrial Appendage Occlusion
This study is to evaluate acute and long-term safety and effectiveness of Left atrial appendage occlusion (LAA)with the AtriCure LAA Occlusion System.
- Trial name
- NCT00567515
- Testing
- AtriCure LAA Exclusion System
- Where
- Switzerland
- Volunteers
- 41 people
- Sponsor
- AtriCure, Inc.
Acute Decompensated Heart Failure, Acute Heart Failure
SVC Occlusion in Subjects With Acute Decompensated Heart Failure
Safety and performance evaluation of the preCARDIA System for patients with ADHF.
- Conditions
- Acute Decompensated Heart Failure, Acute Heart Failure, Congestive Heart Failure, Heart Diseases
- Trial name
- VENUS-HF (NCT03836079)
- Testing
- preCARDIA system
- Where
- 17 sites in United States
- Volunteers
- 60 people
- Sponsor
- Abiomed Inc.