Clinical trials: Bradyarrhythmia
Bradycardia, Sinus Node Dysfunction
LBBAP Data Collection Registry
The purpose of this registry is to evaluate the safety and effectiveness of LBBA pacing/sensing in patients already implanted with the Tendril STS 2088 lead.
- Conditions
- Bradycardia, Sinus Node Dysfunction, Heart Block, Syncope
- Trial name
- NCT05887323
- Testing
- Implantation of the Tendril 2088 lead in the LBBA
- Where
- 11 sites in United States, France and 3 more
- Volunteers
- 221 people
- Sponsor
- Abbott Medical Devices
Bradyarrhythmia
Predictive Factors of a Successful Implant of the CapsureFix MRI Model 5086
Pacing leads are key elements of a pacing system as their proper functioning is one of the major factors affecting the long term performance of the whole system.
- Trial name
- NCT01522755
- Testing
- Pacing system implant with the CapsureFix MRI pacing lead model 5086
- Where
- France
- Volunteers
- 409 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Congenital Heart Disease, Bradycardia Sinus
Specialized Pacing for Patients With Congenital Heart Disease
The closed-loop stimulation (CLS) algorithm is a novel sensor-based technology that relies on the change in myocardial systolic impedance for modulation of the heart rate during physical and emotional stress.3 The pacing…
- Trial name
- NCT03361189
- Testing
- Closed loop stimulation, Standard rate response
- Where
- United States
- Volunteers
- 4 people
- Sponsor
- University of California, Los Angeles
Pacemaker
BRADYCARE: Advanced Bradycardia Device Feature Utilization and Clinical Outcomes
Pacemaker technology is constantly evolving. In the past 10 years, numerous advancements have been made in pacemaker therapy, diagnostics and connectivity.
- Trial name
- BRADYCARE (NCT01062126)
- Volunteers
- 3,389 people
- Sponsor
- Abbott Medical Devices
Pregnancy
Optimizing Dose of Bupivacaine in Combined Spinal Epidurals To Reduce Side Effects
The purpose of this study is to determine what dose of medication administered through a combined spinal epidural (CSE) provides the optimal pain relief with the minimal amount of side effects.
- Trial name
- NCT02159807
- Testing
- Bupivacaine, Fentanyl
- Where
- United States
- Volunteers
- 170 people, healthy volunteers welcome
- Sponsor
- St. Luke's-Roosevelt Hospital Center
Complication Due to Immunization
Cardio-respiratory Events and Inflammatory Response After Primary Immunization in Preterm Infants
Background: Inflammation may depress respiration in neonates. The aim of this study was to establish a link between post-immunization inflammation and cardio-respiratory events (CRE).
- Trial name
- NCT02726178
- Testing
- Advil® Pediatric drops for infants
- Volunteers
- 56 people, healthy volunteers welcome
- Sponsor
- St. Justine's Hospital
SVT, Vagal Bradycardia
Testing of a Valsalva Assist Device (VAD) in Healthy Volunteers Performing a Valsalva Manoeuvre
A prototype for a Valsalva Assist Device (VAD), which provides resistance to exhalation, has been developed and is ready for testing in healthy volunteers.
- Trial name
- NCT03298880
- Testing
- Supine VM VAD, Supine VAD manometer, Modified VM VAD
- Where
- United Kingdom
- Volunteers
- 75 people, healthy volunteers welcome
- Sponsor
- University of Exeter
Bradycardia
Effectiveness of Pacemaker With Closed Loop Stimulation Compared to Pacemakers With and Without Standard Rate Response
This is a randomized, prospective, single-blinded, multi-center study involving approximately 1500 patients at 100 centers. The purpose of this study is to demonstrate the effectiveness of Closed Loop Stimulation (CLS) rate…
- Trial name
- CLEAR (NCT00355797)
- Testing
- Closed Loop Stimulation (CLS), Standard Rate Adaptive (R) Technology, Non-rate adaptive (DDD) pacing
- Where
- 99 sites in United States
- Volunteers
- 1,491 people
- Sponsor
- Biotronik, Inc.
Bradycardia
Micra Transcatheter Pacing System Continued Access Study Protocol
Medtronic is sponsoring the Micra Continued Access (CA) study to provide continued access to the Micra System while the marketing application is under review by the Food and Drug Administration (FDA).
- Trial name
- NCT02488681
- Testing
- Micra Pacemaker Implant
- Where
- 29 sites in United States
- Volunteers
- 285 people
- Sponsor
- Medtronic
Bradycardia
P3: Pacemaker Patient Profiling Study
The P3 Study is a United States post market study to gather data on clinical status, primary indications, device therapy choices, clinical management and outcomes for patients with implantable pacemakers.
- Trial name
- NCT00294060
- Where
- 83 sites in United States
- Volunteers
- 2,013 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Bradycardia, Sinus Node Dysfunction
Physiologic Pacing Registry
The Physiologic Pacing Registry is a prospective, observational, multi-center registry performed to gain a broader understanding of 1) physiologic pacing implant and follow-up workflows, including pacing and sensing measurements…
- Conditions
- Bradycardia, Sinus Node Dysfunction, Heart Block, Syncope
- Trial name
- NCT03719040
- Testing
- Physiologic pacing device implant
- Where
- 50 sites in United States, Australia and 14 more
- Volunteers
- 870 people
- Sponsor
- Abbott Medical Devices
Sudden Cardiac Death, Bradycardia
REASSURE AV Registry
Long term follow-up to monitor safety for patients implanted with a B301 ASSURE device.
- Trial name
- REASSURE (NCT01074034)
- Testing
- AV Therapy Assessment-B301 investigational device
- Where
- 36 sites in United States
- Volunteers
- 211 people
- Sponsor
- Boston Scientific Corporation
Heart Failure, Pacing
Model 4965 Post-Approval Study
Safety and effectiveness will be summarized for the model 4965 lead. This study was conducted within Medtronic's System Longevity Study (SLS).
- Conditions
- Heart Failure, Pacing, Bradycardia, Arrhythmia
- Trial name
- NCT01076348
- Where
- 107 sites in United States, Australia and 12 more
- Volunteers
- 73 people
- Sponsor
- Medtronic
Bradycardia, Heart Failure
ECG Belt to Assess Electrical Synchronization
The objective of the study is to assess the utility of ECG Belt to understand the conduction and ECG characteristics of Left Bundle Branch Pacing (LBBAP) and His-Optimized Cardiac Resynchronization Therapy (HOT-CRT) and compare…
- Trial name
- NCT04583709
- Testing
- ECG Belt
- Where
- United States
- Volunteers
- 20 people
- Sponsor
- Pugazhendhi Vijayaraman
Bradycardia
Accent Cardiac MRI Study
The aim of this study was to assess safety and efficacy of SJM MRI conditional pacing system. The study hypothesized that cardiac MRI scan would not affect performance of SJM MRI conditional pacing system.
- Trial name
- Accent Cardiac (NCT02041702)
- Testing
- Non-Diagnostic Cardiac MRI scan
- Where
- 13 sites in China, Hong Kong and 3 more
- Volunteers
- 283 people
- Sponsor
- Abbott Medical Devices
Strabismus, Reflex, Oculocardiac
Hydroxyzine Dihydrochloride Premedication is a Necessity for Strabismus Surgery
Oculocardiac reflex (OCR) is usually happening in pediatric strabismus surgery and observed just when the surgent pulls the ocular muscles.
- Conditions
- Strabismus, Reflex, Oculocardiac, Hydroxyzine, Bradycardia Sinus
- Trial name
- NCT03806270
- Testing
- Midazolam, Hydroxyzine Dihydrochloride
- Where
- 2 sites in Turkey (Türkiye)
- Volunteers
- 45 people
- Sponsor
- Yeditepe University
Bradycardia
Heart Rate Reducing Therapy in Cardiac CT Using Ivabradine and Bisoprolol
Out-patients scheduled for coronary computer tomographic angiography (CCTA) were screened regarding their baseline heart rate. If heart rate was > 75, patients were pretreated with 10mg bisoprolol (group 1) or 10mg bisoprolol…
- Trial name
- NCT02764970
- Testing
- Ivabradine 7.5mg orally
- Volunteers
- 112 people, healthy volunteers welcome
- Sponsor
- Medical University of Graz
Bradycardia, Congestive Heart Failure
The EASYTRAK EPI Clinical Investigation
The purpose of this study is to assess the safety and effectiveness of the EASYTRAK EPI lead.
- Trial name
- EASYTRAK EPI (NCT00158925)
- Testing
- EASYTRAK EPI lead
- Where
- United States
- Volunteers
- 100 people
- Sponsor
- Boston Scientific Corporation
Bradycardia
Reduction of Right Ventricular Pacing Using the Feature Ventricular Intrinsic Preference (VIP)
The purpose of this study is to evaluate the efficacy of the VIP™ feature (available in dual chamber Victory® devices) to reduce unnecessary RV pacing, and to determine if patients with implanted SJM pacemakers will benefit by…
- Trial name
- NCT00311168
- Testing
- Intervention/treatment
- Where
- United States
- Volunteers
- 135 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation, Atrial Flutter
Suture Closure AFtEr VEIN Access for Cardiac Procedures (SAFE-VEIN) Trial
Primary objective: To compare the safety and efficacy of closure strategies post venous access procedures. Hypothesis: We anticipate that the use of a venous closure device will decrease the time to hemostasis (TTH), time to…
- Conditions
- Atrial Fibrillation, Atrial Flutter, Heart Block, Pulmonary Embolism and Thrombosis
- Trial name
- SAFE-VEIN (NCT04632641)
- Testing
- Perclose ProGlide Suture-Mediated Closure System (SMC) - LARGE-BORE PROCEDURES, Figure 8 Suture - LARGE-BORE PROCEDURES
- Where
- United States
- Volunteers
- 107 people
- Sponsor
- Wake Forest University Health Sciences