Clinical trials: Cardiac and Aortic Surgery
- Condition Cardiac and Aortic Surgery
- Funder type Industry (pharma, biotech, devices)
- Has posted results yes
Aortic Valve Disease, Aortic Stenosis
EDWARDS INTUITY Valve System CADENCE-MIS Study
The study purpose is to compare the EDWARDS INTUITY valve system in a minimal invasive surgical approach (MIS) with any commercially available aortic bioprosthesis in standard full sternotomy surgical approach.
- Trial name
- CADENCE-MIS (NCT02672553)
- Testing
- EDWARDS INTUITY Valve System, Model 8300A, Stented Aortic Bioprostheses
- Where
- Germany
- Volunteers
- 100 people
- Sponsor
- Edwards Lifesciences
Aortic Insufficiency
The HAART 300 Annuloplasty Ring Trial Extended Safety and Performance
This investigation is a prospective, non-randomized, multi-center trial to evaluate the extended safety and performance of the HAART model 300 annuloplasty ring when used to surgically repair the aortic valve using a 3-D…
- Trial name
- NCT01732835
- Testing
- HAART 300 Annuloplasty Device
- Where
- 8 sites in Czechia, Germany
- Volunteers
- 68 people
- Sponsor
- Biostable Science & Engineering
Bicuspid Aortic Valve
Medtronic Transcatheter Aortic Valve Replacement (TAVR) Low Risk Bicuspid Study
The objective of the trial is to evaluate the procedural safety and efficacy of the Medtronic TAVR system in patients with bicuspid aortic anatomy and severe aortic stenosis at low risk for SAVR
- Trial name
- NCT03635424
- Testing
- Medtronic TAVR Systems
- Where
- 25 sites in United States
- Volunteers
- 150 people
- Sponsor
- Medtronic Cardiovascular
Aortic Valve Stenosis
Medtronic CoreValve REDO Study
The proposed investigation is a prospective, multicenter, non-randomized study to evaluate the immediate benefits (at discharge and at 30 days) in terms of performance and safety of the implantation of the Medtronic CoreValve PAV…
- Trial name
- REDO (NCT01051310)
- Testing
- Medtronic CoreValve System
- Where
- 3 sites in Germany, Netherlands
- Volunteers
- 18 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Severe Aortic Stenosis
Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI).
The purpose of the study is to investigate the safety and efficacy of transcatheter aortic valve implantation (TAVI) in patients with severe, symptomatic Aortic Stenosis (AS) at intermediate surgical risk by randomizing patients…
- Trial name
- SURTAVI (NCT01586910)
- Testing
- Medtronic CoreValve® System Transcatheter Aortic Valve Implantation (TAVI), Surgical Aortic Valve Replacement (SAVR), Medtronic CoreValve® Evolut R System Transcatheter Aortic Valve Implantation (TAVI)
- Where
- 86 sites in United States, Canada and 7 more
- Volunteers
- 1,746 people
- Sponsor
- Medtronic Cardiovascular
Surgical Site Infection, Sternal Infection
D-PLEX 302: Efficacy and Safety of D-PLEX in the Prevention of Sternal Infection Post Cardiac Surgery
Prospective, Multinational, Multicenter, Randomized, Parallel Controlled, Two arms, Single Blind, Study to Assess the Efficacy and Safety of D-PLEX Administered Concomitantly with the Standard of Care (SOC) IV Prophylactic…
- Conditions
- Surgical Site Infection, Sternal Infection, Cardiac Surgery
- Trial name
- NCT03558984
- Testing
- D-PLEX, Standard of Care
- Where
- 3 sites in United States, Israel
- Volunteers
- 2 people
- Sponsor
- PolyPid Ltd.
Symptomatic Severe Aortic Stenosis
FlexNav EU CE Mark Study
The purpose of this clinical investigation is to characterize the safety of the next-generation FlexNav™ Delivery System for transfemoral implantation of the Portico™ Transcatheter Aortic Heart Valve in symptomatic severe aortic…
- Trial name
- NCT03724812
- Testing
- Portico Valve and FlexNav™ Delivery System
- Where
- 6 sites in Denmark, Italy and 2 more
- Volunteers
- 46 people
- Sponsor
- Abbott Medical Devices
Symptomatic Severe Aortic Stenosis
Portico Next Generation Approval Study
The purpose of this clinical study is to evaluate the acute safety and effectiveness of the next-generation Navitor (Portico™ NG) Transcatheter Aortic Heart Valve as assessed by the rate of all-cause mortality at 30 days and the…
- Trial name
- NCT04011722
- Testing
- Portico™ NG (Navitor) Valve and FlexNav™ Delivery System, Navitor Titan Valve (35mm) Valve and Large FlexNav™ Delivery System
- Where
- 28 sites in United States, Australia and 3 more
- Volunteers
- 333 people
- Sponsor
- Abbott Medical Devices
Aortic Valve Insufficiency, Aortic Valve Regurgitation
Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra
The purpose of this study is to further evaluate the long-term safety and effectiveness of the Biocor and Biocor Supra Valves.
- Conditions
- Aortic Valve Insufficiency, Aortic Valve Regurgitation, Aortic Valve Stenosis, Aortic Valve Incompetence
- Trial name
- NCT00636987
- Testing
- Biocor and Biocor Supra valves
- Where
- 17 sites in United States
- Volunteers
- 297 people
- Sponsor
- Abbott Medical Devices
Aortic Valve Stenosis
Clinical Evaluation of Percutaneous Implantation of the Medtronic CoreValve Aortic Valve Prosthesis (18Fr-Study)
The investigation concerns a prospective, multicenter, single arm safety and performance study evaluating the Medtronic CoreValve system.
- Trial name
- NCT01051518
- Testing
- Medtronic CoreValve System
- Where
- 9 sites in Canada, Germany and 2 more
- Volunteers
- 126 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Aortic Regurgitation
HAART Model 300 Annuloplasty Ring
This investigation is a prospective, non-randomized, multi-center trial to evaluate the safety and effectiveness of the HAART model 300 annuloplasty ring when used to surgically repair a leaking aortic valve using a 3-D…
- Trial name
- NCT01400841
- Testing
- HAART 300 Annuloplasty Device
- Where
- 4 sites in Belgium, Czechia and 1 more
- Volunteers
- 18 people
- Sponsor
- Biostable Science & Engineering
Aortic Stenosis
PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis
To establish the safety and effectiveness of the Edwards SAPIEN 3 Transcatheter Heart Valve (THV) in patients with severe, calcific aortic stenosis who are at low operative risk for standard aortic valve replacement.
- Trial name
- P3 (NCT02675114)
- Testing
- SAVR, SAPIEN 3 THV
- Where
- 77 sites in United States, Australia and 3 more
- Volunteers
- 1,000 people
- Sponsor
- Edwards Lifesciences
Aortic Valve Disease, Aortic Stenosis
EDWARDS INTUITY Valve System CADENCE Study
The study purpose is to compare the EDWARDS INTUITY valve system with commercially available stented aortic bioprostheses, in patients requiring aortic valve replacement surgery with coronary artery bypass.
- Trial name
- CADENCE (NCT02688153)
- Testing
- EDWARDS INTUITY, Stented aortic bioprostheses
- Where
- France
- Volunteers
- 120 people
- Sponsor
- Edwards Lifesciences
Aortic Stenosis
PERIGON Pivotal Trial
To evaluate the safety and effectiveness of the Model 400 aortic valve bioprosthesis.
- Trial name
- PERIGON (NCT02088554)
- Testing
- Model 400 aortic valve bioprosthesis
- Where
- 38 sites in United States, Canada and 6 more
- Volunteers
- 1,312 people
- Sponsor
- Medtronic Cardiac Surgery