Clinical trials: Degenerative Mitral Valve Regurgitation
Mitral Valve Regurgitation, Mitral Valve Prolapse
Safety and Performance Study of the Harpoon Mitral Valve Repair System
The primary objective of this study is to evaluate the safety and performance of the Harpoon Medical Device. It is anticipated, that the Harpoon Medical Device will provide advantages over current surgical interventions…
- Conditions
- Mitral Valve Regurgitation, Mitral Valve Prolapse, Mitral Valve Insufficiency
- Trial name
- NCT03285724
- Testing
- Harpoon Artificial ePTFE Chords
- Where
- 2 sites in Poland
- Volunteers
- 1 people
- Sponsor
- Edwards Lifesciences
Mitral Valve Insufficiency, Mitral Valve Regurgitation
Pivotal Study of a Percutaneous Mitral Valve Repair System
EVEREST II Randomized Controlled Trial (RCT) is a prospective, multi-center, randomized study of the MitraClip® System in the treatment of mitral valve regurgitation, randomizing patients to MitraClip or mitral valve surgery.
- Conditions
- Mitral Valve Insufficiency, Mitral Valve Regurgitation, Mitral Valve Incompetence, Mitral Regurgitation
- Trial name
- EVERESTIIRCT (NCT00209274)
- Testing
- Percutaneous mitral valve repair using MitraClip implant, Mitral valve repair or replacement surgery
- Where
- United States
- Volunteers
- 279 people
- Sponsor
- Abbott Medical Devices
Severe Degenerative Mitral Regurgitation Due to Mid-segment Posterior Leaflet Prolapse
Observational Registry on the HARPOON Device
To collect data on the HARPOON™ Mitral Valve Repair System for use in patients with severe degenerative mitral regurgitation due to posterior leaflet prolapse.
- Trial name
- REPLICATE (NCT04393779)
- Testing
- HARPOON Beating Heart Mitral Valve Repair System (MVRS)
- Where
- 7 sites in Germany, Spain and 1 more
- Volunteers
- 26 people
- Sponsor
- Edwards Lifesciences
Mitral Valve Insufficiency, Mitral Valve Regurgitation
EVEREST II Pivotal Study High Risk Registry (HRR)
Prospective, multi-center, single arm registry. Clinical follow-up at discharge, 30 days, 6, 12, 18 and 24, months, and 3, 4 and 5 years.
- Conditions
- Mitral Valve Insufficiency, Mitral Valve Regurgitation, Mitral Valve Incompetence, Mitral Regurgitation
- Trial name
- HRR (NCT01940120)
- Testing
- Percutaneous mitral valve repair using MitraClip implant
- Where
- 2 sites in United States
- Volunteers
- 78 people
- Sponsor
- Abbott Medical Devices
Mitral Valve Regurgitation, Mitral Valve Prolapse
CE Mark Study for the Harpoon Medical Device in Poland
The purpose of this study is to evaluate the safety and performance of the Harpoon Medical TSD-5. The Harpoon device will provide many significant advantages over current surgical interventions including: 1) a small minimally…
- Conditions
- Mitral Valve Regurgitation, Mitral Valve Prolapse, Mitral Valve Insufficiency
- Trial name
- NCT02432196
- Testing
- Harpoon Medical Device
- Where
- 2 sites in Poland
- Volunteers
- 26 people
- Sponsor
- Edwards Lifesciences
Mitral Valve Regurgitation, Mitral Valve Prolapse
Safety and Early Feasibility Study of the Harpoon Medical Device (EFS)
The purpose of this study is to evaluate the safety and performance of the Harpoon Medical TSD-5. The Harpoon device will provide many significant advantages over current surgical interventions including: 1) a small minimally…
- Conditions
- Mitral Valve Regurgitation, Mitral Valve Prolapse, Mitral Valve Insufficiency
- Trial name
- EFS (NCT02771275)
- Testing
- Harpoon Medical Device
- Where
- 2 sites in Poland
- Volunteers
- 13 people
- Sponsor
- Edwards Lifesciences
Parkinson's Disease
31P-MRS Imaging to Assess the Effects of CNM-Au8 on Impaired Neuronal Redox State in Parkinson's Disease
REPAIR-PD is a single-center open label pilot, sequential group, investigator and patient blinded study to assess the CNS metabolic effects, safety, pharmacokinetics, and pharmacodynamics of CNM-Au8 in patients who have been…
- Trial name
- REPAIR-PD (NCT03815916)
- Testing
- Gold Nanocrystals
- Where
- United States
- Volunteers
- 13 people
- Sponsor
- Clene Nanomedicine
Mitral Valve Insufficiency, Mitral Valve Regurgitation
Feasibility Study of a Percutaneous Mitral Valve Repair System.
Prospective, multi-center, Phase I study of the Evalve Cardiovascular Valve Repair System (CVRS) in the treatment of mitral valve regurgitation. Patients will undergo 30-day, 6 month, 12 month, and 5 year clinical follow-up.
- Conditions
- Mitral Valve Insufficiency, Mitral Valve Regurgitation, Mitral Valve Incompetence, Mitral Regurgitation
- Trial name
- EVEREST(I) (NCT00209339)
- Testing
- Percutaneous mitral valve repair (MitraClip Implant)
- Where
- United States
- Volunteers
- 55 people
- Sponsor
- Abbott Medical Devices
Mitral Regurgitation, Mitral Insufficiency
Clinical Trial to Evaluate the Safety and Effectiveness of Using the Tendyne Transcatheter Mitral Valve System for the Treatment of Symptomatic Mitral Regurgitation
Prospective, controlled, multicenter clinical investigation with four trial cohorts: Randomized, Non-repairable, Severe Mitral Annular Calcification (MAC) and Severe Mitral Annular Calcification Continued Access Plan (MAC CAP).
- Conditions
- Mitral Regurgitation, Mitral Insufficiency, Mitral Valve Insufficiency, Cardiovascular Diseases
- Trial name
- SUMMIT (NCT03433274)
- Testing
- Tendyne Mitral Valve System, MitraClip System
- Where
- 78 sites in United States, Canada
- Volunteers
- 103 people
- Sponsor
- Abbott Medical Devices
Mitral Valve Insufficiency, Mitral Valve Regurgitation
Real World Expanded Multicenter Study of the MitraClip® System (REALISM)
Prospective, multicenter, continued access registry of the MitraClip® Cardiovascular Valve Repair System in the treatment of mitral valve regurgitation.
- Conditions
- Mitral Valve Insufficiency, Mitral Valve Regurgitation, Mitral Valve Incompetence, Mitral Regurgitation
- Trial name
- REALISM (NCT01931956)
- Testing
- MitraClip® implant
- Where
- 38 sites in United States
- Volunteers
- 965 people
- Sponsor
- Abbott Medical Devices
Mitral Valve Regurgitation
Early Feasibility Study of the Neovasc Tiara™ Mitral Valve System
The purpose of this study is to evaluate the safety and initial performance of the Neovasc Tiara Mitral Transcatheter Heart Valve with the Tiara Transapical Delivery System.
- Trial name
- TIARA-I (NCT02276547)
- Testing
- Mitral valve replacement
- Where
- 10 sites in United States, Belgium and 1 more
- Volunteers
- 27 people
- Sponsor
- Shockwave Medical, Inc.