Clinical trials: Distal Tibial Fracture
Distal Humerus Fracture, Distal Femur Fracture
3D-printed Bone Models in Addition to CT Imaging for Intra-articular Fracture Repair
The purpose of this study is to compare the effectiveness of 3D-printed bone models in addition to CT imaging versus CT imaging alone on surgical quality and operation time for patients undergoing surgical repair of…
- Conditions
- Distal Humerus Fracture, Distal Femur Fracture, Distal Tibia Fracture, Proximal Humeral Fracture
- Trial name
- SPRINT (NCT04748016)
- Testing
- 3D printed (3DP) bone models + CT imaging, CT imaging
- Where
- Hong Kong
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- The University of Hong Kong
Distal Tibial Fracture, Tibial Fracture
Elastic Nailing With Kirschner Wires Versus Plate Fixation for Distal Tibial Fractures in Adolescents
This prospective randomized controlled trial will compare two surgical methods for treating distal tibial metaphyseal-diaphyseal junction fractures in adolescents aged 10 to 16 years.
- Conditions
- Distal Tibial Fracture, Tibial Fracture, Fracture Fixation, Intramedullary, Fracture Fixation, Internal
- Trial name
- NCT07783529
- Testing
- Elastic Stable Intramedullary Nailing Supplemented by Kirschner Wires, Plate fixation
- Where
- Egypt
- Volunteers
- 60 people
- Sponsor
- Sohag University
Tibial Fractures, Femoral Fractures
Distal Locking Using an Electromagnetic Field Guided Computer Based Real Time System for Orthopaedic Trauma Patients
Hypothesis: Utilization of the "wand" method will enhance improvements in drill placement, locking nail placement during tibia and femur fracture repairs, and offer less radiation exposure and less operative time.
- Trial name
- Sure Shot (NCT01183078)
- Testing
- free-hand, Wand technique
- Where
- United States
- Volunteers
- 55 people
- Sponsor
- Wake Forest University Health Sciences
Distal Femur Fracture, Tibial Plateau Fracture
Early Advanced Weight Bearing for Peri-articular Knee and Pilon Injuries
The overall objective of this study is to compare outcomes following early advanced weight bearing (EAWB) using the AlterG antigravity treadmill versus standard of care physical therapy for adult patients with lower extremity…
- Conditions
- Distal Femur Fracture, Tibial Plateau Fracture, Distal Tibia Fracture, Pilon Fracture
- Trial name
- AlterG (NCT03562364)
- Testing
- AlterG anti-gravity treadmill
- Where
- 10 sites in United States
- Volunteers
- 81 people
- Sponsor
- Major Extremity Trauma Research Consortium
Proximal or Diaphyseal Humerus Fracture, Diaphyseal or Distal Femur Fracture
Observational Patient Registry of the Dynamic Locking Screws
The purpose of this multi-center patient registry is to obtain first clinical results and to assess short and mid-term clinical outcome data of patients treated with DLS.
- Conditions
- Proximal or Diaphyseal Humerus Fracture, Diaphyseal or Distal Femur Fracture, Diaphyseal, Distal or Proximal Tibia Fracture
- Trial name
- DLS (NCT02656628)
- Testing
- Dynamic Locking Screw 3.7mm and 5.0mm
- Where
- Australia
- Sponsor
- Synthes GmbH
Hip Fractures, Tibial Fractures
Go Fit Fast, Recovery Trajectory Using PROMIS®, Linking PROMIS®
Prospective data will be collected in approximately 3500 patients (700 per 5 injury groups). Patients will be followed up according to the standard (routine) for up to 1 year after the treatment.
- Conditions
- Hip Fractures, Tibial Fractures, Ankle Fractures, Humeral Fracture, Proximal
- Trial name
- NCT04113044
- Testing
- All treatments will remain the standard (routine) care procedures based on individual clinician's judgment and the patient characteristics.
- Where
- 15 sites in United States, Austria and 4 more
- Volunteers
- 1,500 people
- Sponsor
- AO Innovation Translation Center
Distal Tibial Fracture, Tibial Fractures
Robot-Assisted Closed Reduction and Internal Fixation for Extra-Articular Distal Tibial Fractures
This study aims to evaluate the clinical efficacy and safety of an intelligent fracture reduction robot system in treating extra-articular distal tibial fractures.
- Trial name
- NCT07733271
- Testing
- Robot-assisted closed reduction, Traditional surgeon-led reduction
- Where
- 2 sites in China
- Volunteers
- 60 people
- Sponsor
- Beijing Jishuitan Hospital
Femoral Fractures, Tibial Fractures
Reamed Locked Plating - Metaphyseal Fractures of the Distal Femur and Tibia
Comminuted metaphyseal fractures (OTA classification A2/3 and C2/3) of the distal femur and distal tibia are difficult to treat and typically have more complications than other metaphyseal fractures.
- Trial name
- NCT01553630
- Testing
- RIA bone graft, Surgery without bone graft
- Where
- 2 sites in United States
- Volunteers
- 6 people
- Sponsor
- Florida Orthopaedic Institute
Tibia Distal Fracture, Nonunion of Fracture of Tibia
Is Far Cortical Locking More Effective Than Bicortical Locking in Treating AO 43A1-3 Fractures?
Delayed union or nonunion, which is a common complication of periarticular fractures repaired with angled locking plate systems, may be due to the unintentionally rigid formation of this system.
- Trial name
- NCT06005090
- Testing
- Far Cortical Locking Technique
- Where
- Turkey (Türkiye)
- Volunteers
- 26 people
- Sponsor
- Saglik Bilimleri Universitesi