Clinical trials: Double Lumen Tube
Airway Morbidity, Intubation Complication
Comparison of Double Lumen Tube Placement Techniques
The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required.
- Conditions
- Airway Morbidity, Intubation Complication, Tracheal Intubation Morbidity, Anesthesia Intubation Complication
- Trial name
- NCT02495259
- Testing
- ZU-bend stylet, GlideScope, GlideRite stylet
- Where
- 2 sites in United States
- Volunteers
- 19 people
- Sponsor
- Emory University
One-lung Ventilation
Clamping the Double Lumen Tube
Nowadays, lung isolation techniques are an essential part of thoracic anesthesia. The two principal devices used in order to achieve one-lung ventilation (OLV) are the double lumen tube (DLT) and the bronchial blocker (BB).
- Trial name
- C-TDL (NCT03508050)
- Testing
- Clamping the Double Lumen Tube
- Where
- Canada
- Volunteers
- 37 people
- Sponsor
- Jean Bussières
Lung Collapse, One-Lung Ventilation
Physiology of Lung Collapse Under One-Lung Ventilation: Underlying Mechanisms
Lung isolation technique and one-lung ventilation (OLV) are the mainstays of thoracic anesthesia. Two principal lung isolation techniques are mainly use by clinicians, the double lumen tubes (DLT) and the bronchial blockers (BB).
- Conditions
- Lung Collapse, One-Lung Ventilation, Thoracic Surgery, Video-Assisted
- Trial name
- PLC-OLV (NCT02919267)
- Testing
- Double lumen tube, Bronchial blocker
- Where
- Canada
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Laval University
Thoracic Injuries
EZ-blocker Versus Left Sided Double Lumen Tube in Adult Patients for Thoracic Surgery
The objective of this study is to evaluate the positional stability and quality of lung isolation provided by the EZ-blocker compared to a DLT for both right and left sided thoracic surgery.
- Trial name
- NCT03403192
- Testing
- EZ-Blocker, DLT
- Where
- United States
- Volunteers
- 163 people
- Sponsor
- Wake Forest University Health Sciences
Other Surgical Procedures
Video Double-Lumen Tube Prospective Randomized Study
The goal of this clinical research study is to learn how often a fiberoptic bronchoscopy (FOB -- also known as a fiberoptic scope procedure) needs to be used with a video double lumen tube (VDLT) during surgeries that require…
- Trial name
- NCT02429414
- Testing
- Non-Video Double Lumen Tube (DLT), Fiberoptic Bronchoscopy (FOB), Video Double Lumen Tube (VDLT)
- Where
- United States
- Volunteers
- 83 people
- Sponsor
- M.D. Anderson Cancer Center
Double Lumen Tube Intubation
The New GlideRite DLT Stylet®: An Observational Study
Thoracic surgeries usually require lung isolation techniques. Double-lumen tube (DLT), either right or left sided, is the most frequent tool used to realize this technique.
- Trial name
- NCT01308918
- Where
- Canada
- Volunteers
- 50 people
- Sponsor
- Laval University
Lung Diseases, Ultrasonography
Lung Ultrasonography vs Fiberoptic Bronchoscopy for Aiding Lung Collapse in Patient Using Double Lumen Tube
The study contains the result from a comparison of diagnostic outcomes about lung collapse by using lung ultrasonography as a new diagnostic test compares to fiberoptic bronchoscopy as the standard test.
- Conditions
- Lung Diseases, Ultrasonography, Fiberoptic Bronchoscopy, One Lung Ventilation
- Trial name
- NCT03314519
- Testing
- Lung ultrasonography by experienced anaesthesiologist, Fiberoptic bronchoscopy for double lumen tube's position
- Where
- Thailand
- Volunteers
- 200 people
- Sponsor
- Mahidol University
Double Lumen Endotracheal Tube, Single Lung Ventilation
VivaSight Double Lumen Tube for Single Lung Ventilation
This prospective, randomized, comparative study is intended to enroll a total of 50 patients undergoing thoracic surgery that necessitates single lung ventilation.
- Trial name
- NCT03690284
- Testing
- Conventional Double Lumen Tube, VivaSight Double Lumen Tube
- Where
- United States
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- University of Texas Southwestern Medical Center
Video-assisted Thoracoscopic Surgery, Lung Isolation Device
Lung Collapse With Bronchial Blocker
Lung isolation is frequently used during thoracic surgery. Two techniques are principally used: the double lumen tube (DLT) and the bronchial blocker (BB).
- Conditions
- Video-assisted Thoracoscopic Surgery, Lung Isolation Device, One-lung Ventilation, Double Lumen Endotracheal Tube
- Trial name
- NCT01615263
- Testing
- Lung isolation device
- Where
- Canada
- Volunteers
- 40 people
- Sponsor
- Laval University
Single Lung Ventilation, Thoracic Surgery
Double-lumen Tubes (DLT) - Health Economic Study
The aim of this study is to make a health economic evaluation comparing novice physicians use of VivaSight double-lumen tube and a conventional double-lumen tube for single-lung ventilation during thoracic surgery at a teaching…
- Conditions
- Single Lung Ventilation, Thoracic Surgery, Anesthesia, Cost-effectiveness
- Trial name
- NCT03817879
- Testing
- VivaSight double-lumen tube for single-lung ventilation, Conventional double-lument tube for single-lung ventilation
- Where
- Denmark
- Volunteers
- 70 people
- Sponsor
- Ambu A/S
Endotracheal Tube Wrongly Placed During Anesthetic Procedure, Surgical Procedure, Unspecified
Displacement Between PVC and Silicon DLT
The purpose of this study is to compare difference of displacement between Polyvinyl Chloride(PVC) and Silicon double-lumen endobronchial tubes(DLTs) during changing position from supine to lateral in thoracic surgery.
- Trial name
- NCT02691468
- Testing
- PVC DLT, silicon DLT
- Where
- South Korea
- Volunteers
- 108 people
- Sponsor
- Yeungnam University College of Medicine