Clinical trials: Fracture Mandible
Mandibular Fractures
Customized z Shaped Miniplate Versus Standard 2 Miniplates for Fixation of Parasymphyseal/Body Mandibular Fractures
Mandibular fractures are a common type of facial fractures. The surgical treatment has developed over the years due to improved understanding of biomechanics, biomaterials and scientifically based treatment outcomes.
- Trial name
- NCT07094867
- Testing
- customized Z shaped miniplate, conventional two miniplates
- Where
- Egypt
- Volunteers
- 22 people
- Sponsor
- Hams Hamed Abdelrahman
Mandibular Fractures
Computer Guided Screw Holes Locating Guide and Custom-made Plates
Preoperative CT. Virtual reduction of broken segments on software. Gain occlusion. Design surgical screw holes locating guide. Design the custom-made plates. Print the screw holes locating guide and the custom-made plate.
- Trial name
- NCT05647460
- Testing
- computer guided screw holes locating guide and custom-made plates, conventional plates
- Where
- Egypt
- Volunteers
- 26 people, healthy volunteers welcome
- Sponsor
- Cairo University
Surgical Complication, Paresthesia
Trial of Bilateral Sagittal Split Osteotomy Induced Paresthesia Using Ultrasonic vs. Reciprocating Saw Instrumentation
The aim of this prospective study is to analyze the postoperative paresthesias experienced in patients who undergo bilateral sagittal split osteotomies (BSSO) using an ultrasonic saw, versus a reciprocating saw.
- Conditions
- Surgical Complication, Paresthesia, Fracture, Nerve Injury
- Trial name
- NCT05205616
- Testing
- Sonopet ultrasonic saw, Reciprocating saw
- Where
- 2 sites in United States
- Volunteers
- 32 people, healthy volunteers welcome
- Sponsor
- University of California, San Francisco
Anterior Mandibular Fracture
Single Locking Miniplates Versus Double Non-Locking Miniplates in Anterior Mandibular Fracture
The aim of this study is to compare clinically and radiographically the using of single locking miniplate versus double non-locking miniplates in internal fixation of anterior mandibular fracture
- Trial name
- NCT06938438
- Testing
- single locking miniplate, double conventional miniplates.
- Where
- Egypt
- Volunteers
- 20 people
- Sponsor
- Tanta University
Condylar Neck Fractures, Polyetheretherketone
Clinical and Radiographical Assessment of Patients With Sub-condylar Fracture Using Polyetheretherketone (PEEK) Trapezoidal Plates Versus Titanium Trapezoidal Plates
Some of titanium's drawbacks that is commonly used in maxillofacial surgery included scatter artefacts on regular imaging, implant exposure and inflammation, high thermal conductivity, and high elastic modulus.
- Conditions
- Condylar Neck Fractures, Polyetheretherketone, Mandible Fracture
- Trial name
- NCT06940115
- Testing
- titanium trapezoidal plates, PEEK trapezoidal plates
- Where
- Egypt
- Volunteers
- 24 people
- Sponsor
- Cairo University
Fractures
A New Treatment Protocol for Paediatric Mandibular Condylar Fractures
This study aim to evaluate the clinical and radiographic outcomes of mandibular condylar fractures in pediatrics treated simply with a mandibular manipulation technique accompanied by mouth opening training.
- Trial name
- NCT02237040
- Testing
- Mandibular manipulation technique
- Where
- China
- Volunteers
- 80 people
- Sponsor
- Sun Yat-sen University
Anterior Mandibular Fracture
Evaluation of Condylar Position After Anterior Mandibular Fracture Fixation Using Plates Versus Headless Compression Screws
This study compares two methods for fixing fractures of the front part of the lower jaw: Conventional plates and screws Headless compression screws Patients are randomly assigned to one of the two treatment groups.
- Trial name
- fracture (NCT07826403)
- Testing
- headless compression screw, conventional plates
- Volunteers
- 16 people, healthy volunteers welcome
- Sponsor
- Cairo University
Mandibular Fracture
A New Surgical Instrument in Treatment of Conlylar Fracture: Condylar Reductor
In condylar fracture surgery, reduction is the most difficult step and the key factor which determined the postoperative outcome.
- Trial name
- NCT02850861
- Testing
- Condylar reductor
- Volunteers
- 2 people
- Sponsor
- Junhui Cui
Mandibular Fractures
Specific Screw Holes Locating Surgical Guide and Pre-bent Plates
The aim of the current study was to evaluate the accuracy of computer-guided mandibular fracture reduction versus the classical work flow
- Trial name
- NCT05444829
- Testing
- specific screw holes locating surgical guide and pre-bent plates, classical reduction and internal fixation.
- Volunteers
- 26 people, healthy volunteers welcome
- Sponsor
- Abdallah Gaber Ali Mohamed
Mandibular Body Fractures
Assessment Polyether Ether Ketone (PEEK) Custom Made Plates Versuscustom Made Titanium Plates in Treatment of Mandibular Body Fractures
The design of the custom made Plates is customized to meet the individual needs of each patient and surgeon. By selecting plate design features, surgeons can customize the plate to create a patient specific solution.
- Trial name
- NCT07729345
- Testing
- computer-assisted Polyether ether ketone (PEEK) custom made plates
- Where
- Egypt
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Cairo University
Mandibular Fractures
Open Versus Closed Reduction of Mandibular Sub-Condylar Fractures
Patients with mandibular sub-condylar fractures underwent either either open reduction with internal fixation (ORIF) or closed reduction with external fixation (CREF) and were followed up for 6 months to assess treatment adequacy…
- Trial name
- NCT03494309
- Testing
- Open Reduction & Internal Fixation, Closed Reduction & External Fixation
- Volunteers
- 70 people
- Sponsor
- King Edward Medical University
Displaced Mandibular Angle Fracture
Three Dimensional Versus Standard Miniplate In Fixation Of Mandibular Angle Fracture- A Prospective Randomized Controlled Clinical Trial
The aim of this study is to compare the standard and 3D miniplates fixation in mandibular angle fractures regarding to wound dehiscence, infection, nonunion, pain, hypoesthesia, and malocclusion.
- Trial name
- RCTs (NCT01939015)
- Testing
- 3D titanium miniplate, Standard titanium miniplate- single non compression miniplate
- Where
- Egypt
- Volunteers
- 20 people
- Sponsor
- Cairo University
Bilateral Condylar Fracture of the Mandible
Bilateral Condylar Fractures Registry
Prospective data will be collected in approximately 250 patients sustaining BCFx with or without any additional fracture(s) of the symphysis.
- Trial name
- BCFx (NCT02884765)
- Testing
- Non-surgical, Non-surgical / Surgical, Surgical
- Where
- 21 sites in United States, Finland and 12 more
- Volunteers
- 227 people
- Sponsor
- AO Clinical Investigation and Publishing Documentation
Postoperative Pain, Mandible Fracture
Postoperative Pain After Bupivacaine Supplementation in Mandibular Fracture Surgery
Pain following open reduction of mandibular fractures is the most reported complaint during the first 24 post-operative hours. The goal of this clinical trial is to evaluate the impact of inferior alveolar nerve block with…
- Conditions
- Postoperative Pain, Mandible Fracture, Analgesia, Anesthesia, Local
- Trial name
- NCT06243263
- Testing
- Bupivacain
- Where
- 2 sites in Tunisia
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- University Tunis El Manar
Mandibular Sub-condylar Fracture
3D Custom Plate vs. Standard Titanium Plates for Mandibular Sub-condylar Fractures Fixation
This randomized clinical trial aims to conduct a comprehensive clinical and radiographic evaluation by comparing the efficacy of standard titanium fixation plates with three dimensional custom plate in the management of…
- Trial name
- NCT06978530
- Testing
- 3D custom plate, Standard titanium fixation plates
- Volunteers
- 30 people
- Sponsor
- Esraa Mosad Tawfik
Mandibular Fractures
Mandibular Angle Fracture and Interframents Gap
Twenty-five patients with mandibular angle fracture were subjected to reduction and fixation through intra-oral open reduction and semi-rigid min plate fixation near the superior border of the mandible at Champy's osteosynthesis…
- Trial name
- NCT04729036
- Testing
- open reduction and internal fixation
- Where
- Egypt
- Volunteers
- 25 people
- Sponsor
- Fayoum University
Sagittal and Parasagittal Palatal Fracture
EFFICACY OF TRANSMUCOSAL MINIPLEITE STABILIZATION TECHNIQUE VERSUS INTRA-ARCH WIRE STABILIZATION TECHNIQUE FOR FIXATION OF SAGITTAL & PARA-SAGITTAL TYPES OF PALATAL FRACTURES IN TERMS OF INTRA-ARCH MOLAR DISTANCE & MAXILLO-MANDIBULAR MOLAR RELATION
The purpose of this study is to reduce uncertainity around decision making regarding use of transmucosal miniplate stabilization technique in place of intra-arch wire stabilization technique to get better outcomes.
- Trial name
- NCT07274319
- Testing
- intra arch wire stabilization technique, Transmucosal Miniplate Stabilization
- Where
- Pakistan
- Volunteers
- 40 people
- Sponsor
- Services Institute of Medical Sciences, Pakistan
Mandible Fracture
Comparative Study Evaluating Stability of Fracture Segments After Treatment of Mandibular Angle Fracture With 3d Strut Plate With or Without IMMF.
comparative study evaluating stability of fracture segments in mandibular angle fracture with 3d strut plate with or with out post operative IMMF.
- Trial name
- NCT03640039
- Testing
- 3d strut plate.
- Volunteers
- 16 people, healthy volunteers welcome
- Sponsor
- Cairo University
Mandibular Fractures
CAD/CAM Angle Fracture Reduction/Plate Guide and Customized 3D Grid Plate Versus Champy's Technique
This proposed study aims at creating a computer designed patient specific device and titanium plates, that are 3D manufactured in accordance to a preoperative computer aided virtual surgical procedure, aiming to obtain proper…
- Trial name
- NCT06392204
- Testing
- CAD/CAM patient specfifc fracture reduction/plate guide and customized 3D grid plate, Champy's techqniue
- Where
- Egypt
- Volunteers
- 24 people
- Sponsor
- Cairo University
Anesthesia
The Effect of Inferior Alveolar Nerve Block in Fracture Mandibular Surgeries
The aim of the study is to assess the efficacy of adding of pre-emptive inferior alveolar nerve block compared to the conventional systemic intravenous analgesia in controlling perioperative pain in fracture mandibular surgeries.
- Trial name
- NCT06167187
- Testing
- bilateral inferior alveolar nerve block, Ketorolac and fentanyl
- Where
- Egypt
- Volunteers
- 46 people
- Sponsor
- Ain Shams University