Clinical trials: Glaucoma, Open-angle
Open Angle Glaucoma
Clinical Investigation of the eyeWatch Glaucoma Drainage Device
This study aims to test a new medical device, called the eyeWatch, used in filtering surgery for the treatment of glaucoma. This medical device has the following property: it allows better control of intraocular pressure in the…
- Trial name
- NCT03210571
- Testing
- eyeWatch system
- Where
- United Kingdom
- Volunteers
- 27 people
- Sponsor
- Rheon Medical SA
Graft vs Host Disease, Congenital Aniridia
Safety and Performance Study of the ARGOS-IO System in Patients Undergoing Boston Keratoprosthesis Implantation
The ARGOS-IO pressure sensor is intended to be implanted in the human eye in combination with Boston Keratoprosthesis (BKPro) surgery and to remain in place indefinitely.
- Conditions
- Graft vs Host Disease, Congenital Aniridia, Chemical Burns, Stevens-Johnson Syndrome
- Trial name
- NCT02945176
- Testing
- ARGOS-IO system
- Where
- 2 sites in Germany
- Volunteers
- 13 people
- Sponsor
- Implandata Ophthalmic Products GmbH
Open-angle Glaucoma, Ocular Hypertension
Phase 4 Study Comparing IOP Lowering in OAG or OH in Caucasian or Japanese Subjects C-02-32
The purpose of this study is to evaluate safety and efficacy of two different IOP lowering medications after six weeks of treatment in Caucasian and Japanese subjects.
- Trial name
- NCT00047606
- Testing
- IOP Lowering Medications
- Volunteers
- 84 people
- Sponsor
- Alcon Research
Primary Open Angle Glaucoma
The Effects of Visior on Ocular Hemodynamics
To determine the relationship between the affects of viewing commercially available content through the VISIOR video goggles and ocular blood flow in glaucoma patients and healthy subjects.
- Trial name
- NCT02959593
- Testing
- VISIOR video goggles
- Where
- United States
- Volunteers
- 35 people, healthy volunteers welcome
- Sponsor
- Visior Technologies Ltd.
Glaucoma, Open-Angle
Study of an Interposition Supraciliary Implant in Patients With Open Angle Glaucoma
The purpose of this study is to prolong observational follow-up up to 36 months of patients already implanted with a novel interposition supraciliary implant.
- Trial name
- SAFARI FU (NCT05159817)
- Where
- Armenia
- Volunteers
- 19 people
- Sponsor
- Ciliatech
Open-angle Glaucoma
Safety and Efficacy of the GTS400 Stent in Conjunction With Cataract
To evaluate the safety and efficacy of the Glaukos Trabecular Micro-Bypass Stent Model GTS400 in conjunction with cataract surgery, compared to cataract surgery only, in subjects with mild to moderate open angle glaucoma.
- Trial name
- NCT00721968
- Testing
- Glaucoma Stent Surgery (GTS400 Stent), cataract surgery alone
- Volunteers
- 62 people
- Sponsor
- Glaukos Corporation
Open-Angle Glaucoma, Ocular Hypertension
To Investigate the Safety and Efficacy of DE-104 Ophthalmic Solution to Treat Open-Angle Glaucoma or Ocular Hypertension
To investigate the intraocular pressure (IOP)-lowering effect and safety of DE-104 ophthalmic solution in patients with Primary Open-Angle Glaucoma or Ocular Hypertension
- Trial name
- NCT00656240
- Testing
- DE-104 ophthalmic solution, DE-104 vehicle
- Where
- Japan
- Sponsor
- Santen Pharmaceutical Co., Ltd.
Glaucoma, Glaucoma, Open-Angle
Glaucoma Surgery Using the ViaLase Laser System
Prospective, single-center, multi-cohort clinical trial of ViaLase Laser for the reduction of IOP in patients with open angle glaucoma.
- Trial name
- NCT04949802
- Testing
- ViaLase Laser
- Where
- Hungary
- Volunteers
- 22 people
- Sponsor
- Vialase, Inc.
Open-Angle Glaucoma, Ocular Hypertension
A Single Dose Comfort Comparison of Travatan Z in One Eye Versus Xalatan in the Opposite Eye in Patients With Primary Open-Angle Glaucoma or Ocular Hypertension
The purpose of this study is to compare the comfort of Travatan Z in one eye and Xalatan in the opposite eye in patients with primary open-angle glaucoma or ocular hypertension.
- Trial name
- NCT00527592
- Testing
- Travoprost ophthalmic solution 0.004% with SofZia® preservative system (TRAVATAN Z®), Latanoprost ophthalmic solution 0.005% (XALATAN®)
- Volunteers
- 54 people
- Sponsor
- Alcon Research
Glaucoma
Phase 2 Study of BL1107 Eye Drops vs. Timolol in Adults With Primary Open Angle Glaucoma or Ocular Hypertension
Phase 2 Study of BL1107 Eye Drops vs. Timolol in Adults with Primary Open Angle Glaucoma or Ocular Hypertension
- Trial name
- NCT07168902
- Testing
- BL1107 Low dose, BL1107 High dose, Timolol maleate 0.5%
- Where
- 14 sites in United States
- Volunteers
- 252 people
- Sponsor
- Bausch & Lomb Incorporated
Glaucoma, Glaucoma, Open Angle
SOLX Gold Shunt Versus Control Implant: Randomized Trial for Refractory Glaucoma
Study Objective: To establish the substantial equivalence of the SOLX Gold Shunt to commercially available aqueous shunts, specifically the Ahmed™ Glaucoma Valve Model FP7, in the ability to reduce intraocular pressure (IOP)…
- Trial name
- NCT00382395
- Testing
- SOLX Gold Shunt GMS-plus, Ahmed FP7 Glaucoma Valve
- Where
- 15 sites in United States, Canada and 3 more
- Volunteers
- 180 people
- Sponsor
- SOLX, Inc.
Ocular Hypertension, Open-angle Glaucoma
Double-masked Study of AR-13324 Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension
To evaluate the ocular hypotensive efficacy and ocular and systemic safety of AR-13324 Ophthalmic Solution, 0.02% compared to the active comparator Timolol maleate Ophthalmic Solution, 0.5%
- Trial name
- Rocket-1 (NCT02207491)
- Testing
- Timolol maleate Ophthalmic Solution 0.5% BID, AR-13324 Ophthalmic Solution 0.02%
- Where
- United States
- Volunteers
- 411 people
- Sponsor
- Aerie Pharmaceuticals
Glaucoma, Open-Angle Ocular Hypertension
A Comparison of Bimatoprost SR to Selective Laser Trabeculoplasty in Patients With Open-Angle Glaucoma or Ocular Hypertension
This study will evaluate the intraocular pressure (IOP)-lowering effect and safety of Bimatoprost SR compared with selective laser trabeculoplasty in participants with open-angle glaucoma or ocular hypertension who are not…
- Trial name
- NCT02636946
- Testing
- Bimatoprost SR, Selective Laser Trabeculoplasty
- Where
- 33 sites in United States, Australia and 7 more
- Volunteers
- 144 people
- Sponsor
- Allergan
Ocular Hypertension, Open Angle Glaucoma
Nocturnal/Diurnal Intraocular Pressure-Lowering Effect of Netarsudil Ophthalmic Solution
To evaluate effect of Netarsudil Ophthalmic Solution 0.02% on Nocturnal and Diurnal Intraocular Pressure.
- Trial name
- NCT02874846
- Testing
- Netarsudil ophthalmic solution 0.02%, Netarsudil Ophthalmic Solution Vehicle
- Where
- United States
- Volunteers
- 12 people
- Sponsor
- Aerie Pharmaceuticals
Primary Open Angle Glaucoma of Both Eyes
Comparative Study of Dorzol Eye Drops, 20 mg/ml Versus Trusopt® Eye Drops, 20 mg/ml
The goal of this study is to compare efficacy and safety of Dorzol 20 mg/mL Eye Drops manufactured by JADRAN-GALENSKI LABORATORIJ d.d.
- Trial name
- NCT05973305
- Testing
- Dorzol 20 mg/ml, Trusopt 20 mg/ml
- Where
- Russia
- Volunteers
- 118 people
- Sponsor
- Jadran Galenski laboratorij d.d.
Primary Open Angle Glaucoma, Healthy Subjects
Efficacy of 24-hour Intraocular Pressure Fluctuation Recording With the SENSIMED Triggerfish Contact Lens Sensor
The objectives of this study are to assess the safety and effectiveness of the SENSIMED Triggerfish® (TF) device in continuous recording of relative fluctuation in intraocular pressure (IOP).
- Trial name
- NCT01390779
- Testing
- SENSIMED Triggerfish
- Where
- United States
- Volunteers
- 33 people, healthy volunteers welcome
- Sponsor
- Sensimed AG
Open-angle Glaucoma, Ocular Hypertension
A Study of DE-111A on the Treatment of Open Angle Glaucoma or Ocular Hypertension
The objective of this study is to investigate whether the IOP (intraocular pressure) -lowering effect of DE-111A (preservative-free fixed dose combination of 0.0015% tafluprost and 0.5% timolol eye drops, administered one drop a…
- Trial name
- NCT03822559
- Testing
- A preservative-free, a clear, colorless sterile aqueous ophthalmic solution containing 0.015mg of tafluprost and 5.0mg of timolol in 1mL, A preservative-free, a clear, colorless sterile aqueous ophthalmic solution containing 0.015mg of tafluprost in 1mL
- Where
- 2 sites in China
- Volunteers
- 219 people
- Sponsor
- Santen Pharmaceutical Co., Ltd.
Glaucoma, Open-Angle, Ocular Hypertension
A Study of Bimatoprost in the Treatment of Primary Open Angle Glaucoma and Ocular Hypertension
This is a study of bimatoprost as initial, replacement, or adjunctive intraocular pressure (IOP)-lowering therapy in patients with primary open angle glaucoma and ocular hypertension.
- Trial name
- LOTUS (NCT02061683)
- Testing
- Bimatoprost 0.03%
- Where
- China
- Volunteers
- 263 people
- Sponsor
- Allergan
Open-angle Glaucoma
24 Hour IOP Lowering Efficacy of AL-3789
The objective of this study was to describe the intraocular pressure-lowering efficacy of AL-3789 over a 24-hour period in patients with open-angle glaucoma compared to an untreated control.
- Trial name
- NCT00643669
- Testing
- AL-3789 Sterile Suspension
- Where
- United States
- Volunteers
- 25 people
- Sponsor
- Alcon Research
Open Angle Glaucoma, Ocular Hypertension
DE-111 Against Timolol Ophthalmic Solution 0.5%
DE-111 ophthalmic solution will be evaluated for superiority in comparison with Timolol ophthalmic solution 0.5%, in IOP(intraocular pressure ) -lowering effect in primary open-angle glaucoma or ocular hypertension patients, in a…
- Trial name
- NCT01342094
- Testing
- DE-111 ophthalmic solution, Timolol ophthalmic solution 0.5%
- Where
- Japan
- Volunteers
- 166 people
- Sponsor
- Santen Pharmaceutical Co., Ltd.