Clinical trials: Heart Rate Low
Bradycardia, Chronotropic Incompetence
Common Sensing and Right Ventricular Automatic Capture (COGNATE)
This study will collect data on features for future pacemakers via an external non-implantable system.
- Trial name
- COGNATE (NCT01030705)
- Where
- 5 sites in United States
- Volunteers
- 80 people
- Sponsor
- Boston Scientific Corporation
Pacemaker, Bradycardia
VIBRANT Registry: Value of Information Based From Pacemaker Recordings and New Technologies
The purpose of this study is to collect data from pacemakers and determine how this information is used by physicians to care for their patients with pacemakers.
- Trial name
- NCT00294034
- Testing
- Pacemaker
- Where
- 27 sites in United States
- Volunteers
- 950 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Arrhythmia, Bradycardia
Product Performance Report: Evaluate Long-term Reliability & Performance of Medtronic Marketed Cardiac Therapy Products
The main purpose of the Product Performance Report (formerly referred to as System Longevity Study) is to evaluate long-term performance of Medtronic market-released cardiac rhythm products by analyzing product survival…
- Conditions
- Arrhythmia, Bradycardia, Heart Failure, Sinus Tachycardia
- Trial name
- PPR (NCT00271180)
- Testing
- Device
- Where
- 333 sites in United States, Australia and 33 more
- Volunteers
- 20,000 people
- Sponsor
- Medtronic
Bradycardia, Tachycardia
China 3T MRI Study
The purpose of the China CIED 3.0T MRI Performance Study is to confirm safety of SureScan CIED in the clinical 3.0T MRI environment when subjects receive MRI scans.
- Conditions
- Bradycardia, Tachycardia, Heart Failure
- Trial name
- NCT06038123
- Testing
- China market released 3.0T Magnetic resonance (MR) conditional CIED systems
- Where
- 5 sites in China
- Volunteers
- 64 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Cardiac Pacing, Pacing Therapy
Electrogram and Hemodynamic Characteristics of Adaptive LBBAP in Patients With Heart Failure or Bradycardia
This is a multi-site, non-randomized, data collection study. The purpose of this study is to investigate the cardiac electrical and mechanical function during LBBAP with different AV intervals.
- Trial name
- NCT04738396
- Where
- 4 sites in China
- Volunteers
- 52 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Atrial Fibrillation, Tachycardia, Supraventricular
Preliminary Research Evaluation for Ambulatory Leadless Electrocardiogram Recorder Trial
The clinical study is intended to implement and test the collection and analysis of paired ECG data from the HeartWatch and two comparator devices, an Event Recorder and Holter.
- Conditions
- Atrial Fibrillation, Tachycardia, Supraventricular, Bradyarrhythmia, Ventricular Arrythmia
- Trial name
- PRE-ALERT (NCT05357716)
- Testing
- HeartWatch, Event Recorder, Holter Monitor
- Where
- Canada
- Volunteers
- 7 people
- Sponsor
- HelpWear Inc.
Bradycardia
Conduction System Pacing Display Research System for SmartSync Pacing System Analyzer
The purpose of this study is to collect and compare the heart's electrical activity data measured by the novel Conduction System Pacing (CSP) Display Research System with data measured via 12 lead electrocardiogram (ECG) from a…
- Trial name
- CSP Display (NCT07733960)
- Testing
- CSP Display research system
- Where
- 2 sites in India
- Volunteers
- 100 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Sudden Cardiac Death, Bradycardia
REASSURE AV Registry
Long term follow-up to monitor safety for patients implanted with a B301 ASSURE device.
- Trial name
- REASSURE (NCT01074034)
- Testing
- AV Therapy Assessment-B301 investigational device
- Where
- 36 sites in United States
- Volunteers
- 211 people
- Sponsor
- Boston Scientific Corporation
Bradycardia, Atrioventricular Block
BIOTRONIK Conduction System Pacing With the Solia Lead
The purpose of the BIO-CONDUCT study is to demonstrate the safety and effectiveness of the BIOTRONIK Solia S pacing lead when implanted in the left bundle branch (LBB) area.
- Conditions
- Bradycardia, Atrioventricular Block, Left Bundle-Branch Block, Cardiomyopathies
- Trial name
- BIO-CONDUCT (NCT05251363)
- Testing
- Solia S lead
- Where
- 14 sites in United States
- Volunteers
- 194 people
- Sponsor
- Biotronik, Inc.
Adverse Effect of MRI on an Implanted Pacemaker Lead, Adverse Effect of MRI on an Implanted Pacemaker
Safety and Efficacy of the Accent Magnetic Resonance Imaging™ (MRI) Pacemaker and Tendril MRI™ Lead
The MRI Study is a prospective, multi-center, clinical study designed to evaluate the safety and efficacy of the Accent MRI™ System in a patient population indicated for implant of a pacemaker within and outside of the MRI…
- Trial name
- NCT01576016
- Testing
- Accent MRI system (lead safety), Accent MRI system (with MRI scan)
- Where
- 70 sites in United States, Australia and 3 more
- Volunteers
- 950 people
- Sponsor
- Abbott Medical Devices
Standard Bradycardia Pacing Indication
Advanced Bradycardia Device Feature Utilization and Clinical Outcomes II
The purpose of this study is to characterize the utilization of diagnostics capabilities in St. Jude Medical pacemakers to manage patients with a standard bradycardia pacing indication.
- Trial name
- BRADYCARE II (NCT02577887)
- Testing
- Patients implanted with a St. Jude Medical pacemakers
- Where
- 4 sites in France, Germany and 2 more
- Volunteers
- 2,101 people
- Sponsor
- Abbott Medical Devices
Bradycardia, Sick Sinus Syndrome
Beluga - Clinical Observations of Automatic Algorithms for Cardiac Pacing
This study shall evaluate in daily medical practice the clinical results of the AV delay hysteresis search algorithm in patients with a INSIGNIA ULTRA or AVT pacemaker implanted for one of the three following indications: sinus…
- Conditions
- Bradycardia, Sick Sinus Syndrome, Heart Block
- Trial name
- NCT00286858
- Testing
- Insignia Ultra and Insignia AVT
- Where
- 40 sites in France, Guadeloupe
- Volunteers
- 903 people
- Sponsor
- Boston Scientific Corporation
Bradycardia, Hypertension, Systolic
Preload and Autonomic Responses With Cardiac Neuromodulation Therapy (CNT) (CS-06)
This investigation will evaluate the effect of RV pacing lead position on cardiac function and the modulation of the autonomic nervous system with Cardiac Neuromodulation Therapy (CNT) pacing signals.
- Trial name
- CS-06 (NCT04463121)
- Testing
- Moderato IPG's CNT pacing signals, CD Leycom Pressure/Volume Combination Catheters
- Where
- Czechia
- Volunteers
- 22 people
- Sponsor
- BackBeat Medical Inc
Tachycardia, Ventricular, Heart Failure, Congestive
OMNI Study--Assessing Therapies in Medtronic Pacemaker, Defibrillator, and Cardiac Resynchronization Therapy Devices.
The purpose of the OMNI study is to characterize therapy and diagnostic utilization in study participants implanted with study devices and to describe Implantable Cardioverter Defibrillator(ICD)therapy utilization for life…
- Conditions
- Tachycardia, Ventricular, Heart Failure, Congestive, Ventricular Fibrillation, Ventricular Dysfunction
- Trial name
- OMNI (NCT00277524)
- Where
- 113 sites in United States
- Volunteers
- 3,032 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Bradycardia
Accent Cardiac MRI Study
The aim of this study was to assess safety and efficacy of SJM MRI conditional pacing system. The study hypothesized that cardiac MRI scan would not affect performance of SJM MRI conditional pacing system.
- Trial name
- Accent Cardiac (NCT02041702)
- Testing
- Non-Diagnostic Cardiac MRI scan
- Where
- 13 sites in China, Hong Kong and 3 more
- Volunteers
- 283 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation (AF), Atrial Flutter
Head-to-Head (H2H) Comparison of Ambulatory Cardiac ECG Monitors in Japan
The goal of this clinical trial is to compare the yield of clinically actionable arrhythmias through the end of indicated wear duration in Zio monitor and Heartnote patch ECG devices.
- Conditions
- Atrial Fibrillation (AF), Atrial Flutter, Supraventricular Tachycardia (SVT), Ventricular Tachycardia (VT)
- Trial name
- Japan H2H (NCT07870837)
- Testing
- Application of ambulatory cardiac monitor
- Where
- 4 sites in Japan
- Volunteers
- 130 people
- Sponsor
- iRhythm Technologies, Inc.
Bradycardia, Arrhythmia
PREFER (Pacemaker Remote Follow-Up Evaluation and Review)
The purpose of the study is to compare remote pacemaker follow-up to current standard of care follow-up. The study will compare the rate of first diagnosis of clinically actionable events between patients who utilize the…
- Trial name
- NCT00294645
- Testing
- Transtelephonic monitoring (TTM), Medtronic CareLink® Network
- Where
- 45 sites in United States
- Volunteers
- 980 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Cardiac Pacemaker, Artificial, Cardiac Rhythm Disorder
Aveir DR i2i Study
Prospective, non-randomized, multi-center, international study designed to evaluate the safety and effectiveness of the Aveir™ Dual-Chamber (DR) Leadless Pacemaker system.
- Conditions
- Cardiac Pacemaker, Artificial, Cardiac Rhythm Disorder, Bradycardia
- Trial name
- NCT05252702
- Testing
- Aveir DR Leadless Pacemaker System
- Where
- 78 sites in United States, Austria and 11 more
- Volunteers
- 464 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation, Bradycardia
Prospective Registry of Pacemaker Patients Concerning Percentage of Right Ventricular Pacing, LVEF and NYHA Class
This registry is a data collection on patients who are implanted for more than 6 months with a pacemaker. Frequency and distribution of right ventricular pacing, NYHA class and left ventricular ejection fraction shall be…
- Conditions
- Atrial Fibrillation, Bradycardia, Heart Block, Sick Sinus Syndrome
- Trial name
- NCT00292539
- Testing
- Any pacemaker with right ventricular pacing option
- Where
- Germany
- Volunteers
- 600 people
- Sponsor
- Guidant Corporation
Cardiac Pacing, Artificial, Cardiac Pacemaker, Artificial
BIO|MASTER.CSP Study
The goal of this clinical study is to test the clinical safety and performance of the Amvia pacemakers and the Solia CSP S lead when used for left bundle branch area pacing (LBBAP).
- Conditions
- Cardiac Pacing, Artificial, Cardiac Pacemaker, Artificial, Cardiac Resynchronization Therapy Devices, Bradycardia
- Trial name
- NCT06620237
- Testing
- Implantation of the Solia CSP S pacing lead for LBBAP
- Where
- 14 sites in Australia, Belgium and 3 more
- Volunteers
- 152 people
- Sponsor
- Biotronik SE & Co. KG