Clinical trials: Heart Valve Replacement
Aortic Stenosis
Association of Type of Anesthetic and Outcomes in Transfemoral Aortic Valve Replacement
This study proposes to perform a descriptive analysis and pilot observational study looking at the types and quantity of anesthetic agents used and their associations with outcomes among patients scheduled to receive transfemoral…
- Trial name
- NCT02786264
- Testing
- Dexmedetomidine with propofol, Propofol
- Volunteers
- 186 people
- Sponsor
- Yale University
Aortic Stenosis, Mitral Stenosis
ProspeCtive, nOn-randoMized, MulticENter Clinical Evaluation of Edwards Pericardial Bioprostheses With a New Tissue Treatment Platform (COMMENCE)
The objective of this trial is to confirm that the modifications to tissue processing, valve sterilization and packaging do not raise any new questions of safety and effectiveness in subjects who require replacement of their…
- Conditions
- Aortic Stenosis, Mitral Stenosis, Aortic Valve Insufficiency, Mitral Valve Insufficiency
- Trial name
- COMMENCE (NCT01757665)
- Testing
- Edwards Aortic and Mitral Bioprostheses Models 11000A and 11000M
- Where
- 32 sites in United States, Canada and 1 more
- Volunteers
- 777 people
- Sponsor
- Edwards Lifesciences
Symptomatic Severe Aortic Stenosis
FlexNav EU CE Mark Study
The purpose of this clinical investigation is to characterize the safety of the next-generation FlexNav™ Delivery System for transfemoral implantation of the Portico™ Transcatheter Aortic Heart Valve in symptomatic severe aortic…
- Trial name
- NCT03724812
- Testing
- Portico Valve and FlexNav™ Delivery System
- Where
- 6 sites in Denmark, Italy and 2 more
- Volunteers
- 46 people
- Sponsor
- Abbott Medical Devices
Mitral Valve Disease, Damaged Mitral Valve
HALO: A Single Arm Prospective Investigation of the SJM™ Masters HP™ 15mm Rotatable Mechanical Heart Valve
The purpose of the study is to provide evidence of safety and effectiveness of the study valve. The rationale is to offer a replacement mitral valve for patients with anatomy that is too small for the currently commercially…
- Conditions
- Mitral Valve Disease, Damaged Mitral Valve, Malfunctioning Mitral Heart Valve, Mitral Valve Replacement
- Trial name
- NCT02097420
- Testing
- Mitral valve replacement SJM™ Masters HP™ 15mm Rotatable Mechanical Heart Valve
- Where
- 24 sites in United States
- Volunteers
- 23 people
- Sponsor
- Abbott Medical Devices
Right Ventricular Dysfunction
TEE 3D RV Assessment for SAVR, Mini AVR, and TAVR
Three-dimensional echocardiography has become a gold standard to assess right ventricular (RV) function, and investigators plan to use 3D transesophageal echocardiography to assess RV function in 3 types of aortic valve…
- Trial name
- NCT05804240
- Testing
- 3D TEE RVEF
- Where
- United States
- Volunteers
- 67 people
- Sponsor
- Thomas Jefferson University
Patients Waiting for Coronary Artery Bypass Graft Surgery, Patients Waiting for Aortic Valve Repair or Replacement
Pre-operative Rehabilitation for Reduction of Hospitalization After Coronary Bypass and Valvular Surgery.
The PREHAB study is a clinical trial where frail patients waiting for heart surgery are randomly chosen to either receive the current standard of care or to participate in an 8-week exercise/education program at a community-based…
- Conditions
- Patients Waiting for Coronary Artery Bypass Graft Surgery, Patients Waiting for Aortic Valve Repair or Replacement, Patients Waiting for Mitral Valve Repair or Replacement, Patients Waiting for Combined Procedures. (CAGB and Valve)
- Trial name
- PREHAB (NCT02219815)
- Testing
- Prehab Intervention
- Where
- 5 sites in Canada
- Volunteers
- 89 people
- Sponsor
- St. Boniface Hospital
Aortic Valve Disease, Aortic Stenosis
Perceval Sutureless Implant Versus Standard-Aortic Valve Replacement
Prospective, randomized, stratified non blinded multi-center, international, post market trial assessed in a non-inferiority study. The trial has a flexible sample size that will be determined adaptively.
- Trial name
- PERSIST-AVR (NCT02673697)
- Testing
- Perceval valve, other stented biological valve
- Where
- 47 sites in United States, Austria and 10 more
- Volunteers
- 914 people
- Sponsor
- Corcym S.r.l
Aortic Valve Disease, Mitral Valve Disease
Artificial Valve Endocarditis Reduction Trial
The purpose of this study is to investigate whether the Silzone coated sewing cuff reduces the incidence of prosthetic valve endocarditis (PVE).
- Conditions
- Aortic Valve Disease, Mitral Valve Disease, Endocarditis
- Trial name
- AVERT (NCT00590889)
- Testing
- Artificial Mechanical Heart Valve
- Where
- 16 sites in United States, Canada and 6 more
- Volunteers
- 807 people
- Sponsor
- Abbott Medical Devices
Aortic Stenosis
Aortic Stenosis and PhosphodiEsterase iNhibition With Aortic Valve Replacement (ASPEN-AVR): A Pilot Study
Currently, aortic stenosis (AS) is considered a "surgical disease" with no medical therapy available to improve any clinical outcomes, including symptoms, time to surgery, or long-term survival.
- Trial name
- ASPEN-AVR (NCT01272388)
- Testing
- Tadalafil
- Where
- United States
- Volunteers
- 1 people
- Sponsor
- Washington University School of Medicine
Aortic Valve Stenosis
The SAPIEN 3 Ultra System in Intermediate Risk Patients With Symptomatic, Severe Aortic Stenosis
This study will confirm the procedural safety and performance of the SAPIEN 3 Ultra System in subjects with severe, calcific AS who are at intermediate operative risk for standard aortic valve replacement.
- Trial name
- NCT03471065
- Testing
- SAPIEN 3 Ultra Delivery System with the SAPIEN 3 Ultra THV
- Where
- 6 sites in Canada, United Kingdom
- Volunteers
- 100 people
- Sponsor
- Edwards Lifesciences
Antimicrobial Prophylaxis
A Pilot Study of Daptomycin for Antimicrobial Prophylaxis
The goals of the study are to evaluate the feasibility of using daptomycin as a prophylactic antimicrobial agent in patients undergoing cardiac surgery, to determine the rates of surgical site infection, and to evaluate the…
- Trial name
- NCT00572260
- Testing
- daptomycin 6 mg/kg IV
- Where
- United States
- Volunteers
- 11 people
- Sponsor
- Duke University
Aortic Valve Disease, Aortic Stenosis
EDWARDS INTUITY Valve System CADENCE-MIS Study
The study purpose is to compare the EDWARDS INTUITY valve system in a minimal invasive surgical approach (MIS) with any commercially available aortic bioprosthesis in standard full sternotomy surgical approach.
- Trial name
- CADENCE-MIS (NCT02672553)
- Testing
- EDWARDS INTUITY Valve System, Model 8300A, Stented Aortic Bioprostheses
- Where
- Germany
- Volunteers
- 100 people
- Sponsor
- Edwards Lifesciences
Aortic Valve Disease, Aortic Stenosis
EDWARDS INTUITY Valve System CADENCE Study
The study purpose is to compare the EDWARDS INTUITY valve system with commercially available stented aortic bioprostheses, in patients requiring aortic valve replacement surgery with coronary artery bypass.
- Trial name
- CADENCE (NCT02688153)
- Testing
- EDWARDS INTUITY, Stented aortic bioprostheses
- Where
- France
- Volunteers
- 120 people
- Sponsor
- Edwards Lifesciences
Aortic Valve Stenosis
Clinical Evaluation of Percutaneous Implantation of the Medtronic CoreValve Aortic Valve Prosthesis (18Fr-Study)
The investigation concerns a prospective, multicenter, single arm safety and performance study evaluating the Medtronic CoreValve system.
- Trial name
- NCT01051518
- Testing
- Medtronic CoreValve System
- Where
- 9 sites in Canada, Germany and 2 more
- Volunteers
- 126 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Symptomatic Aortic Stenosis
Portico TAVI Implant With Transfemoral Delivery System
The purpose of this study is to assess the safety and effectiveness of the SJM Portico Transcatheter Heart Valve and the SJM TAVI Transfemoral Transcatheter delivery system in subjects with severe symptomatic aortic stenosis (AS).
- Trial name
- NCT01493284
- Testing
- Transcatheter Aortic Valve Implantation
- Where
- 14 sites in Australia, Denmark and 3 more
- Volunteers
- 222 people
- Sponsor
- Abbott Medical Devices
Severe Symptomatic Calcified Native Aortic Valve Stenosis
Cerebral Protection in Transcatheter Aortic Valve Replacement
The Sentinel System will be a safe and effective method for capturing and removing embolic material (thrombus/debris) during transcatheter aortic valve replacement in order to reduce the ischemic burden in the cerebral anterior…
- Trial name
- NCT02214277
- Testing
- Cerebral Protection System-The SENTINEL System with TAVR, TAVR
- Where
- 15 sites in United States, Germany
- Volunteers
- 363 people
- Sponsor
- Claret Medical
Aortic Valve Stenosis
Hemodynamic Comparison of Tissue Aortic Valves
The purpose of this study is to: 1. Assess for hemodynamic differences at rest and with exercise between three clinically available tissue aortic valves. 2.
- Trial name
- NCT01635244
- Testing
- Aortic valve replacement
- Where
- United States
- Volunteers
- 60 people
- Sponsor
- University of Michigan
Bicuspid Aortic Valve
Medtronic Transcatheter Aortic Valve Replacement (TAVR) Low Risk Bicuspid Study
The objective of the trial is to evaluate the procedural safety and efficacy of the Medtronic TAVR system in patients with bicuspid aortic anatomy and severe aortic stenosis at low risk for SAVR
- Trial name
- NCT03635424
- Testing
- Medtronic TAVR Systems
- Where
- 25 sites in United States
- Volunteers
- 150 people
- Sponsor
- Medtronic Cardiovascular
Mitral Valve Insufficiency
Transcatheter Mitral Valve Replacement System (TMVR) Pilot Study and The Early Feasibility Study of the TMVR Transseptal System
PILOT: The study is a pilot trial to evaluate the safety and performance of the Twelve TMVR System in high risk mitral regurgitation patients.
- Trial name
- NCT02322840
- Testing
- Twelve TMVR Implant, Medtronic Intrepid™ Transcatheter Transfemoral Mitral Valve Replacement System
- Where
- 32 sites in United States, Australia and 5 more
- Volunteers
- 128 people
- Sponsor
- Medtronic Cardiovascular
Aortic Stenosis
ACURATE IDE: Safety and Effectiveness Study of ACURATE Valve for Transcatheter Aortic Valve Replacement
To evaluate safety and effectiveness of the ACURATE Transfemoral Aortic Valve System for transcatheter aortic valve replacement (TAVR) in subjects with severe native aortic stenosis who are indicated for TAVR.
- Trial name
- NCT03735667
- Testing
- ACURATE neo2™ Transfemoral TAVR System, Medtronic CoreValve TAVR System, Edwards SAPIEN 3 TAVR System
- Where
- 75 sites in United States, Canada
- Volunteers
- 1,948 people
- Sponsor
- Boston Scientific Corporation