Clinical trials: High Risk PCI
Coronary Artery Lesions
XIENCE 90: A Safety Evaluation of 3-month DAPT After XIENCE Implantation for HBR Patients.
XIENCE 90 study is a prospective, single arm, multi-center, open label trial to evaluate the safety of 3-month dual antiplatelet therapy (DAPT) in subjects at high risk of bleeding (HBR) undergoing percutaneous coronary…
- Trial name
- NCT03218787
- Testing
- XIENCE, DAPT
- Where
- 101 sites in United States
- Volunteers
- 2,047 people
- Sponsor
- Abbott Medical Devices
Acute Coronary Syndrome
Fondaparinux Trial With Unfractionated Heparin (UFH) During Revascularization in Acute Coronary Syndromes (ACS)
The purpose of this study is to compare the safety of two different dose regimens of unfractionated heparin (UFH) during a percutaneous coronary intervention (PCI) procedure in patients with UA (unstable angina)/NSTEMI (non ST…
- Trial name
- FUTURA/OASIS 8 (NCT00790907)
- Testing
- fondaparinux background and standard dose UFH, Fondaparinux background and low dose heparin, Open label fondaparinux
- Where
- 203 sites in United States, Argentina and 16 more
- Volunteers
- 3,235 people
- Sponsor
- GlaxoSmithKline
Bleeding Disorder, Ischemic Stroke
XIENCE 28 USA Study
The XIENCE 28 USA Study is prospective, single arm, multi-center, open label, non-randomized trial to evaluate safety of 1-month (as short as 28 days) dual antiplatelet therapy (DAPT) in subjects at high risk of bleeding (HBR)…
- Conditions
- Bleeding Disorder, Ischemic Stroke, Hemorrhagic Stroke, Hematological Diseases
- Trial name
- NCT03815175
- Testing
- XIENCE, DAPT (aspirin and/or P2Y12 receptor inhibitor)
- Where
- 111 sites in United States, Austria and 13 more
- Volunteers
- 1,605 people
- Sponsor
- Abbott Medical Devices
Coronary Artery Disease
Vortex - Temporary Percutaneous, Transvalvular Circulatory Support System Feasibility Study
Vortex - First in Human study to evaluate the feasibility, safety, clinical and technical success of the Vortex temporary percutaneous, transvalvular circulatory support system (Vortex System)
- Trial name
- Vortex-FIH (NCT04674111)
- Testing
- Temporary Percutaneous Transvalvular Circulatory Support System (Vortex System)
- Where
- 2 sites in Australia, Sweden
- Volunteers
- 5 people
- Sponsor
- Boston Scientific Corporation
Graft Versus Host Disease (GVHD)
Treatment of GVHD in Hematopoietic Stem Cell Transplant (HSCT) Recipients Using AAT Plus Corticosteroids (CS) Compared With Corticosteroids Alone
Study CSL964_5001 will investigate the efficacy of AAT with corticosteroids compared with corticosteroids alone as first line therapy for patients with high-risk acute GVHD
- Trial name
- NCT04167514
- Testing
- Alpha-1 antitrypsin (AAT)
- Where
- 25 sites in United States
- Volunteers
- 136 people
- Sponsor
- CSL Behring
Coronary Artery Disease
EVOLVE Short DAPT Study
The EVOLVE Short DAPT Study is a prospective, multicenter, single-arm study designed to assess the safety of 3-month DAPT in subjects at high risk for bleeding undergoing PCI with a SYNERGY Stent System.
- Trial name
- NCT02605447
- Testing
- 3 months of dual antiplatelet therapy (DAPT), SYNERGY Stent System
- Where
- 110 sites in United States, Brazil and 5 more
- Volunteers
- 2,009 people
- Sponsor
- Boston Scientific Corporation
Coronary Artery Diseases, Multivessel Coronary Artery Disease
SYNTAX III REVOLUTION Trial: A Randomized Study Investigating the Use of CT Scan and Angiography of the Heart to Help the Doctors Decide Which Method is the Best to Improve Blood Supply to the Heart in Patients With Complex Coronary Artery Disease
The SYNTAX III Revolution trial is a randomized diagnostic research study that investigates the use of CT scan and angiogram of the heart to help doctors decide which method is the best to improve blood supply to the heart in…
- Conditions
- Coronary Artery Diseases, Multivessel Coronary Artery Disease, Heart Diseases, Cardiovascular Diseases
- Trial name
- SYNTAX III (NCT02813473)
- Testing
- Coronary Angiography, Computed Tomography (CT) scan
- Where
- 6 sites in Belgium, France and 3 more
- Volunteers
- 223 people
- Sponsor
- ECRI bv
Shock, Cardiogenic, High Risk Percutaneous Coronary Interventions
Synchronized Cardiac Assist for Cardiogenic Shock
The purpose of this study is to collect prospective safety and performance information for the i-COR® device using synchronized cardiac assist in the setting of combined heart-lung failure or in high risk percutaneous…
- Trial name
- NCT02697006
- Testing
- i-cor Synchronized Cardiac Assist Device
- Where
- Germany
- Volunteers
- 47 people
- Sponsor
- Xenios AG
Coronary Artery Disease (CAD)
Testing Platelet Reactivity In Patients Undergoing Elective Stent Placement on Clopidogrel to Guide Alternative Therapy With Prasugrel (TRIGGER-PCI)
To determine the efficacy of prasugrel versus clopidogrel for the reduction of adverse cardiovascular outcomes in patients with high platelet reactivity on clopidogrel after successful implantation of coronary drug-eluting…
- Trial name
- TRIGGER-PCI (NCT00910299)
- Testing
- Prasugrel, Clopidogrel
- Where
- 27 sites in United States, Germany
- Volunteers
- 423 people
- Sponsor
- Eli Lilly and Company
Myocardial Infarction, Acute Coronary Syndromes
Shortened Aggrastat® Versus Integrilin in Percutaneous Coronary Intervention
The purpose this study is to assess whether a tirofiban regimen of a high-dose bolus plus a shortened infusion duration compared to label-dosing eptifibatide in patients undergoing percutaneous coronary intervention (PCI) is…
- Conditions
- Myocardial Infarction, Acute Coronary Syndromes, Unstable Angina
- Trial name
- SAVI-PCI (NCT01522417)
- Testing
- Short Tirofiban, Eptifibatide, Long Tirofiban
- Where
- 13 sites in United States
- Volunteers
- 535 people
- Sponsor
- Medicure
Coronary Artery Disease
SHIELD II Clinical Investigation
The HeartMate PHP System is a temporary (<6 hours) ventricular assist device indicated for use during high-risk percutaneous coronary interventions (PCI) performed electively or urgently in hemodynamically stable patients with…
- Trial name
- SHIELD II (NCT02468778)
- Testing
- HeartMate PHP, Any Abiomed Impella® device approved for use in high-risk PCI
- Where
- 58 sites in United States
- Volunteers
- 54 people
- Sponsor
- Abbott Medical Devices