Clinical trials: Humerus, Fracture
Humeral Fracture, Proximal, Glenohumeral Osteoarthritis
RETRO-PROSPECTIVE POSTMARKET CLINICAL STUDY FOR FX SHOULDER SOLUTIONS SHOULDER SYSTEMS
This study takes place in the framework of the PostMarket Clinical Follow-up plan of the Shoulder Systems commercialized by FX SHOULDER SOLUTIONS. The included cases will be followed for 10 years after index surgery.
- Conditions
- Humeral Fracture, Proximal, Glenohumeral Osteoarthritis, Avascular Necrosis of the Head of Humerus, Rotator Cuff Tear
- Trial name
- NCT07558590
- Testing
- Shoulder arthroplasty
- Where
- 22 sites in France, Monaco
- Volunteers
- 1,004 people
- Sponsor
- FX Solutions
Fracture
Evaluation of Treatment of Fractures of the Humerus With a Plate.
The purpose of this study is to study with the use of clinical and radiological parameters the treatment of three-part and four-part fractures with the Winsta PH osteosynthesis device (Fischer Medical).
- Trial name
- NCT00408291
- Testing
- Winsta PH osteosynthesis device
- Where
- Denmark
- Volunteers
- 36 people
- Sponsor
- University of Aarhus
Reproducibility, Four Part Fracture
Analysis of Four-fragment Fractures of the Proximal Humerus: the Interest of 2D and 3D Imagery and Inter- and Intra-observer Reproducibility
Fractures of the proximal humerus are increasingly frequent, with numbers tripling between the 1970s and the 2000s. Among these fractures, those involving the tuberosities and also the anatomic neck are a therapeutic challenge.
- Conditions
- Reproducibility, Four Part Fracture, Proximal Humerus Fracture, Hertel's Criteria
- Trial name
- REPROD-HUMERUS (NCT03646253)
- Testing
- Analysis of radiology (standard radiographies, 2D scan sections and 3D reconstructions)
- Where
- France
- Volunteers
- 20 people
- Sponsor
- CHU de Reims
Humeral Fracture
Does Teriparatide (rhPTH 1-34) Promote Fracture Healing in Proximal Humeral Fractures?
40 postmenopausal women, with a non-operated proximal humeral fracture, will be randomized to standard treatment (physiotherapy) or standard treatment + Forsteo (rhPTH 1-34) during 4 weeks.
- Trial name
- NCT01105832
- Testing
- Teriparatide
- Where
- 2 sites in Sweden
- Volunteers
- 40 people
- Sponsor
- University Hospital, Linkoeping
Interferential Current in Proximal Humerus Fractures
IFC Therapy in Proximal Humerus Fractures
Proximal humerus fractures (PHFs) frequently occur in the elderly and osteoporotic population, but these fractures are also common in individuals under age 60 years.
- Trial name
- NCT04553497
- Testing
- Interferential current, Rehabilitation program
- Where
- Turkey (Türkiye)
- Volunteers
- 35 people
- Sponsor
- Ege University
Pediatric Supracondylar Humeral Fracture
HM vs Fibreglass Cast Immbolization for Supracondylar Fractures
Supracondylar humeral fractures are the most common elbow fractures in children and cast immobilization continues to remain as the recommended treatment for modified Gartland's classification Type I and Type IIa injuries.
- Trial name
- NCT05430074
- Testing
- HM Cast, Fibreglass Cast
- Where
- Singapore
- Volunteers
- 79 people
- Sponsor
- KK Women's and Children's Hospital
Proximal Humeral Fracture
A Research Study to Understand and Predict the Failure of Shoulder Fracture Fixations Using Computer Simulations
Fractures of the shoulder, the so-called proximal humeral fractures, can be treated with locking plates that have shown good results in clinical practice, but complications can occur.
- Trial name
- PHILOS-SIM (NCT04056351)
- Testing
- Post-Operative (OP) Computer Tomography (CT), Questionnaires on patient activity and comorbidities, Grip strength measurement
- Where
- 2 sites in Austria, Belgium
- Volunteers
- 29 people
- Sponsor
- AO Research Institute Davos
Shoulder Fracture
Efficacy of Shoulder Mobilisation Versus Conventional Immobilisation for Nonsurgically Proximal Humerus Fracture
Background: Nonsurgical proximal humerus fracture is common, causing prolonged disability, for which the time to begin rehabilitation is not well determined.
- Trial name
- NCT00326794
- Testing
- mobilisation (rehabilitation)
- Where
- France
- Volunteers
- 76 people, healthy volunteers welcome
- Sponsor
- Assistance Publique - Hôpitaux de Paris
Proximal Humeral Fracture
Impact of Regional Anesthesia on Blood Pressure in Humeral Fracture Surgery
This study aims to compare the hemodynamic impact of two anaesthetic strategies : Regional anesthesia versus General anesthesia in proximal humeral fracture surgery.
- Trial name
- ALR_HUMERUS (NCT05153902)
- Where
- France
- Volunteers
- 250 people
- Sponsor
- University Hospital, Montpellier
Humeral Fracture
The Effect of the Timing of Postoperative Mobilisation After Locking Plate Osteosynthesis of Fractures of the Surgical Neck of the Humerus
Open reduction and locking plate osteosynthesis is a commonly used and well-accepted treatment for displaced fractures of the proximal humerus.
- Trial name
- NCT01524965
- Testing
- Immediate mobilisation after locking-plate osteosynthesis, Standard mobilisation after locking plate osteosynthesis, Osteosynthesis with a locking plate (Philos)
- Where
- Finland
- Volunteers
- 94 people
- Sponsor
- University of Helsinki
Supracondylar Humerus Fracture
Supracondylar Post-Operative Pain Study
The purpose of this study to investigate post-operative pain control in pediatric patients with closed supracondylar humerus fracture who undergo closed reduction and percutaneous pinning.
- Trial name
- NCT03759028
- Testing
- Ibuprofen, Oxycodone, Acetaminophen
- Where
- United States
- Volunteers
- 90 people
- Sponsor
- University of California, Los Angeles
Proximal or Diaphyseal Humerus Fracture, Diaphyseal or Distal Femur Fracture
Observational Patient Registry of the Dynamic Locking Screws
The purpose of this multi-center patient registry is to obtain first clinical results and to assess short and mid-term clinical outcome data of patients treated with DLS.
- Conditions
- Proximal or Diaphyseal Humerus Fracture, Diaphyseal or Distal Femur Fracture, Diaphyseal, Distal or Proximal Tibia Fracture
- Trial name
- DLS (NCT02656628)
- Testing
- Dynamic Locking Screw 3.7mm and 5.0mm
- Where
- Australia
- Sponsor
- Synthes GmbH
Osteoarthritis, Rheumatoid Arthritis
A Clinical Investigation of the Copeland™ Humeral Resurfacing Head
The purpose of this study is to perform a five-year, prospective evaluation of the Copeland™ Humeral Resurfacing Head Prosthesis for outcome and durability.
- Conditions
- Osteoarthritis, Rheumatoid Arthritis, Avascular Necrosis, Humeral Fractures
- Trial name
- NCT00698750
- Volunteers
- 34 people
- Sponsor
- Biomet Orthopedics, LLC
Humeral Fracture
Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures
Extra-articular distal-third humeral shaft fractures are difficult to treat because stable fixation must be achieved while minimizing soft-tissue injury and the risk of nerve damage.
- Trial name
- NCT07645768
- Testing
- Reversed PHILOS Plate, Posterior Double Plate Fixation
- Where
- Egypt
- Volunteers
- 68 people
- Sponsor
- Cairo University
Distal Humerus Fracture
Does Surgical-approach Affect Outcome After Fixation of Intra-articular Fractures of Distal Humerus?
observational study at tertiary care hospital and level 1 trauma centre aiming to evaluate the difference between two common surgical approaches to distal humerus fracture fixation.
- Trial name
- NCT03833414
- Testing
- triceps lifting and olecranon osteotomy approaches
- Volunteers
- 43 people, healthy volunteers welcome
- Sponsor
- Aga Khan University
Closed Fracture of Shaft of Humerus
HUmeral Shaft Fracture FIXation Study
Fractures of the humeral shaft (upper arm bone) account for approximately 1% of all adult fractures in the United Kingdom. Historically, these injuries have been treated using a cast and/or brace, with immediate surgical fixation…
- Trial name
- HU-FIX (NCT03689335)
- Testing
- Operative, Humeral brace
- Where
- United Kingdom
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Royal Infirmary of Edinburgh
Proximal Humeral Fracture
Evidence Based Algorithm for Proximal Humerus Fractures
Proximal humerus fractures are particularly frequent injuries and represent 6% of all fractures with an overall incidence of 63/100.000 in human.
- Trial name
- NCT03464578
- Testing
- Therapy of proximal humeral fractures (irrespective conservative or operative)
- Where
- Switzerland
- Volunteers
- 143 people
- Sponsor
- Cantonal Hospital of St. Gallen
Closed Fracture of Shaft of Humerus
Operative Versus Nonoperative Treatment of Humeral Shaft Fractures: A Prospective Cohort Comparison Study
The subject's broken humerus (arm) is suitable for treatment with a fracture brace or operative fixation with plate and screws. Both of these types of treatments are often used by doctors to fix broken bones.
- Trial name
- NCT01363518
- Where
- 7 sites in United States
- Volunteers
- 164 people
- Sponsor
- St. Louis University
Proximal Humeral Fracture, Surgical Treatment
Tranexamic Acid in Proximal Humeral Fractures
The purpose of this study is to determine the effect of tranexamic acid (on blood loss and transfusion requirements in patients with proximal humeral fractures requiring open surgical approaches.
- Trial name
- NCT05437822
- Testing
- Tranexamic acid
- Where
- Spain
- Volunteers
- 40 people
- Sponsor
- Elda University Hospital
Humerus Fracture
Low Dose Interscalene and Infraclavicular Block for Humerus Surgery
Combining interscalene block with infraclavicular block for humerus surgery provides a unique surgical anaesthesia and postoperative analgesia.
- Trial name
- NCT02756156
- Volunteers
- 30 people
- Sponsor
- Kahramanmaras Sutcu Imam University