Clinical trials: Iliac Aneurysms
Abdominal Aortic Aneurysm
Acute Technical Outcomes of the Talent Abdominal Aortic Aneurysm (AAA) Stent-Graft Versus Cook Zenith Stent-Graft
The purpose of this study is to compare acute technical outcomes of the Talent AAA Stent Graft system versus Cook Zenith Endograft at two high volume institutions, Albany Medical Center and St. Peter's Hospital in Albany, NY.
- Trial name
- NCT00922454
- Testing
- Endovascular Repair of the abdominal aorta, Cook Zenith Stent-Graft, Talent Stent-Graft
- Where
- United States
- Volunteers
- 200 people
- Sponsor
- Center for Vascular Awareness, Albany, New York
Abdominal Aortic, Aorto-iliac Aneurysm
Zenith Alpha™ Abdominal Endovascular Graft
The purpose of this study is to evaluate the clinical performance of the Zenith Alpha™ Abdominal Endovascular Graft for the treatment of abdominal aortic or aorto-iliac aneurysm.
- Trial name
- NCT03061825
- Testing
- Zenith Alpha™ Abdominal Endovascular Graft
- Where
- 5 sites in Canada
- Volunteers
- 100 people
- Sponsor
- Cook Research Incorporated
Mycotic Aneurysm, Aortic Diseases
International Multicenter Mycotic Aneurysm Aorto-iliac Study
The term mycotic aneurysm (MA) is commonly used to describe all infected aneurysms. Although MAs are believed to occur uncommonly, the true incidence is difficult to determine and is probably underestimated since MAs can be…
- Trial name
- MAAI (NCT05777447)
- Testing
- Mycotic aortic-iliac aneurysms and in situ reconstruction
- Where
- Italy
- Volunteers
- 40 people
- Sponsor
- Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Aorto-iliac Aneurysms, Iliac Aneurysms
PRESERVE-Zenith® Iliac Branch System Clinical Extended Study
The PRESERVE-Zenith® Iliac Branch System Clinical Study is a clinical trial to collect confirmatory safety and effectiveness data on the Zenith® Branch Endovascular Graft-Iliac Bifurcation System.
- Trial name
- NCT02571985
- Testing
- Zenith® Branch Endovascular Graft-Iliac Bifurcation System
- Where
- 19 sites in United States
- Sponsor
- Cook Group Incorporated
Iliac Aneurysm, Angiography
Iliac Branch Device Movement During Cardiac Cycle (IBD-dynamics)
The incidence of isolated common iliac artery (CIA) aneurysms is low, but in combination with an abdominal aortic aneurysm (AAA) they are found in approximately 20-40% of cases.
- Conditions
- Iliac Aneurysm, Angiography, AAA
- Trial name
- NCT03762525
- Testing
- ECG gated CTA
- Where
- 3 sites in Netherlands
- Volunteers
- 45 people
- Sponsor
- Rijnstate Hospital
Abdominal Aortic Aneurysm, Infrarenal Abdominal Aortic Aneurysm
Fast-Track Protocol for Endovascular Aneurysm Repair (EVAR) of Infrarenal Abdominal Aortic Aneurysms
The study aims to evaluate the clinical and economic efficacy of a "Fast-Track" protocol for the elective endovascular treatment (EVAR) of infrarenal abdominal aortic aneurysms (AAA).
- Conditions
- Abdominal Aortic Aneurysm, Infrarenal Abdominal Aortic Aneurysm, Penetrating Aortic Ulcers (PAUs), Iliac Aneurysm
- Trial name
- NCT07431047
- Volunteers
- 50 people
- Sponsor
- University of Bologna
Aortic Aneurysm
Abdominal Aortic/Aorto-Iliac Aneurysm Endoluminal Graft Study
The Bifurcated PowerLink System is intended to provide a permanent alternative conduit for blood flow within a patient's abdominal vascular system, which excludes the aneurysmal sac from blood flow and pressure.
- Trial name
- NCT00549354
- Testing
- Endoluminal Graft
- Where
- United States
- Volunteers
- 34 people
- Sponsor
- Arizona Heart Institute
Abdominal Aortic Aneurysms
Safety Study for the Treatment of Abdominal Aortic Aneurysms
The primary study objective, at this time, is to follow out to 5 years post implant the safety of already enrolled subjects who were treated with the UniFit Aorto-uni-iliac (AUI) Endoluminal Stent Graft (the "study device") for…
- Trial name
- UNITE (NCT00610090)
- Testing
- UniFit AAA Stent Graft
- Where
- 19 sites in United States
- Volunteers
- 71 people
- Sponsor
- Duke Vascular, Inc.
Abdominal Aortic Aneurysm, Aorto-iliac Aneurysm
Zenith® Spiral-Z® AAA Iliac Leg Graft Post-market Registry
The purpose of this registry is to obtain case reports of physician experience with the Spiral-Z® graft under routine clinical care.
- Trial name
- NCT01540643
- Testing
- Iliac Leg Graft
- Where
- 31 sites in United States, Canada
- Volunteers
- 600 people
- Sponsor
- Cook Group Incorporated
Abdominal Aortic Aneurysms
Endurant Bifurcated and Aorto-Uni-Iliac (AUI) Stent Graft System
To demonstrate safety and effectiveness of the Endurant Stent Graft in the treatment of Abdominal Aortic or Aorto-Uni-Iliac Aneurysms.
- Trial name
- NCT00705718
- Testing
- Endurant Stent Graft System
- Where
- 30 sites in United States
- Volunteers
- 194 people
- Sponsor
- Medtronic Cardiovascular
Aortic Aneurysm, Iliac Aneurysm
Safety and Efficacy of the Gore® Excluder® Iliac Branch Platform and Analysis of Its Behavior in Combination With the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis (IBERVIX)
Aorto-iliac aneurysms with involvement of the iliac bifurcation or hypogastric artery aneurysms constitute only 20% of all aneurysmal pathology of the abdominal aorta.
- Trial name
- IBERVIX (NCT04356313)
- Testing
- GORE® EXCLUDER® Iliac Branch Endoprosthesis
- Where
- Spain
- Volunteers
- 100 people
- Sponsor
- Asociacion para el Estudio de la Enfermedades Vasculares de Galicia
Abdominal Aortic Aneurysm, Aorto-iliac Aneurysm
Zenith Low Profile AAA Endovascular Graft (ZLP) Clinical Study
A prospective study conducted in Japan to collect confirmatory peri-operative and 30-day information on use of the Zenith LP AAA Graft.
- Conditions
- Abdominal Aortic Aneurysm, Aorto-iliac Aneurysm, Iliac Aneurysm
- Trial name
- ZLP (NCT01326884)
- Testing
- ZLP
- Where
- 2 sites in Japan
- Volunteers
- 27 people
- Sponsor
- Cook Group Incorporated
Iliac Aneurysm, Aortic Aneurysm, Abdominal
iHub Stent-Graft for Iliac Artery Aneurysms: Safety, Performance, and Effectiveness Study
The goal of this clinical trial is to evaluate the safety, performance, and Preliminary effectiveness of the iHub endoprosthesis system in treating iliac artery aneurysms in adult patients requiring endovascular repair.
- Trial name
- TriHub (NCT07005141)
- Testing
- Endovascular Iliac Branch Stent-Graft Implantation
- Where
- 2 sites in Brazil
- Volunteers
- 10 people
- Sponsor
- Archo Medical S.A
Aortoiliac Aneurysms, Iliac Aneurysms
PRESERVE-Zenith® Branch Endovascular Graft-Iliac Bifurcation
The purpose of this extended study is to collect confirmatory safety and effectiveness data on the Zenith® Branch Endovascular Graft-Iliac Bifurcation in combination with the commercially available Atrium iCAST™ covered stent in…
- Trial name
- NCT02475798
- Testing
- Zenith® Branch Endovascular Graft-Iliac Bifurcation,
- Where
- 26 sites in United States
- Sponsor
- Cook Research Incorporated
Peripheral Artery Disease, Abdominal Aortic Aneurysm
Endovascular Treatment of Aorto-iliac Disease Using in Situ Fenestration
In situ fenestration (ISF) could represent an alternative in the treatment of aorto-iliac disease when usual techniques are not available. The aim of this study was to present the results of ISF in aorto-iliac disease.
- Trial name
- PREFISIT (NCT04062734)
- Where
- France
- Volunteers
- 30 people
- Sponsor
- Assistance Publique - Hôpitaux de Paris
Aortic Aneurysm, Abdominal, Aorto Iliac Aneurysm
The STAPLE International Post-Market Registry
The Aptus Endosystems STAPLE International Post-Market Registry is intended to expand the clinical knowledge base by including 'real world' subjects.
- Trial name
- NCT01276249
- Testing
- Fortevo Endograft
- Where
- 9 sites in Canada, Germany and 4 more
- Volunteers
- 108 people
- Sponsor
- Medtronic Cardiovascular
Aortoiliac Aneurysm, Iliac Aneurysm
Safety and Efficacy Study of Iliac Bifurcation Stent Graft System
A prospective, multi-centre, single-arm clinical trial to evaluate the safety and efficacy of Iliac Bifurcation Stent Graft System.
- Trial name
- NCT03686189
- Testing
- Iliac Bifurcation Stent Graft System
- Where
- 8 sites in China
- Volunteers
- 64 people
- Sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.
Aorto-iliac Aneurysm
Evaluation Of Cost-Effectiveness Of Iliac Branch Endoprostheses
The study is a multi-center, voluntary observational study on an ambispective cohort of patients treated between January 2018 and December 2025.The study aims to enroll 300 patients (around 200 patients in the retrospective…
- Trial name
- ECO-IBE (NCT07096388)
- Testing
- endovascular repair, open surgical repair
- Where
- Italy
- Volunteers
- 300 people
- Sponsor
- Prof. Andrea Kahlberg
Aortoiliac Aneurysm, Iliac Aneurysm
CAMpania PugliA bRanch Iliaco
Spontaneus Multicentric Observational registry to investigate the medium and long-term performances of the Iliac E-liac Branch Device from Artivion for treatment of Aortoiliac aneurysms in a real-world consecutive patients cohort.
- Trial name
- CAMPARI (NCT06946381)
- Testing
- Evar
- Where
- 2 sites in Italy
- Volunteers
- 200 people
- Sponsor
- Federico II University
Aortic Aneurysm, Thoracoabdominal
Pilot Study of BAO-G Technique in TAAA Endovascular Repair
Multi-Branch AOrtic Reconstruction With G-iliac System (BAO-G) Technique is a novel technique of endovascular repair of thoracoabdominal aortic aneurysm, which using off-the-shelf iliac branched devices to reconstruct the…
- Trial name
- NCT06534281
- Testing
- BAO-G
- Where
- China
- Volunteers
- 20 people
- Sponsor
- Peking Union Medical College Hospital