Clinical trials: Oxygen Therapy; Heart Surgery
Sepsis, Post Cardiac Surgery Low Output Syndrome Requiring Inotropic/Vasopressor Therapy
Comparison of Central Venous Oxygen Saturation Measurements by Non-invasive Mespere Venous Oximeter and Central Venous Catheter
The intent of this study is to validate the venous blood oxygenation measurements of the Mespere VA Oximeter compared to the saturations measured by venous blood sampling through an inserted central vein catheter, which is…
- Conditions
- Sepsis, Post Cardiac Surgery Low Output Syndrome Requiring Inotropic/Vasopressor Therapy, Cardiogenic Shock Post Myocardial Infarction, Hypoxemic Respiratory Failure.
- Trial name
- NCT01788956
- Testing
- Mespere Venous Oximeter, Co-Oximeter
- Where
- Canada
- Volunteers
- 40 people
- Sponsor
- Mespere Lifesciences Inc.
Cardiovascular Disease
Phase II Study To Evaluate The Safety and Efficacy of Hemoglobin Raffimer in Patients Undergoing First Time CABG Surgery
To evaluate the efficacy of Hemolink™ in combination with Intraoperative Autologous Donation (IAD) versus control (IAD alone) in facilitating avoidance of allogeneic RBC transfusion during and following primary CABG surgery
- Trial name
- NCT00038454
- Testing
- Hemolink (hemoglobin raffimer IV solution)
- Where
- 28 sites in United States, Canada and 1 more
- Volunteers
- 180 people
- Sponsor
- Hemosol
Coronary Artery Disease, Heart Valve Diseases
Spectroscopic Assessment of Intramyocardial Oxygen Saturation During Open-Heart Surgery
The goal of this observational study is to test in the safety and performance of intraoperative myocardial spectroscopic measurement in open-heart surgery patients The main questions it aims to answer are: The Devices can record…
- Trial name
- ECS (NCT06084091)
- Testing
- Myocardial spectrometric measurement
- Where
- Finland
- Volunteers
- 40 people
- Sponsor
- Spectrocor
Brain Monitor, Anaesthesia
Evaluation of the BRAINDEX Brain Monitor in Cardiac Surgery, Interventional Comparative Study
The main objective of this study is to show the concordance of the SctO2 values of the ARGOS platform with the standard SctO2 values (comparative study with platform INVOS, Medtronic).
- Trial name
- ARGOS Platform (NCT06594198)
- Testing
- Cerebral monitor
- Where
- France
- Volunteers
- 40 people
- Sponsor
- Braindex
Coronary Artery Disease, Heart Valve Diseases
Spectroscopic Assessment of Intramyocardial Oxygen Saturation Feasibility During Open-heart Surgery
This traditional feasibility study aims to capture preliminary safety and effectiveness information on a near-final Investigational Device design to adequately plan the forthcoming pivotal study.
- Trial name
- NCT05479968
- Testing
- Spectrocor device
- Where
- Finland
- Volunteers
- 15 people
- Sponsor
- Spectrocor
Single Ventricle Heart Disease After Fontan Surgery
Pharmacokinetic/Pharmacodynamic Study of Udenafil in Adolescents
To determine the pharmacokinetic profile and safety of udenafil in adolescents with Fontan physiology and to assess the short-term pharmacodynamic effect of udenafil on pharmacodynamic measures of exercise capacity, ventricular…
- Trial name
- NCT02201342
- Testing
- Udenafil
- Where
- 6 sites in United States, Canada
- Volunteers
- 36 people
- Sponsor
- Mezzion Pharma Co. Ltd