Clinical trials: Paroxysmal AF
Paroxysmal Atrial Fibrillation
Electrical Coupling Information From The RHYTHMIA HDx Mapping System and DIRECTSENSE Technology In The Treatment of Paroxysmal Atrial Fibrillation (LOCALIZE CF)
The objective of this study is to evaluate whether local impedance (DIRECTSENSE™) drop on the INTELLANAV STABLEPOINT™ ablation catheter is associated with late pulmonary vein (PV) reconnections and durable conduction block in…
- Trial name
- LOCALIZE CF (NCT04740801)
- Testing
- Ablation procedure
- Where
- 5 sites in Germany, Italy and 1 more
- Volunteers
- 60 people
- Sponsor
- Boston Scientific Corporation
Paroxysmal Atrial Fibrillation
A Comparison of Antiarrhythmic Drug Therapy and Radio Frequency Catheter Ablation in Patients With Paroxysmal Atrial Fibrillation
The purpose of this study is to compare radiofrequency catheter ablation and antiarrhythmic drug treatment for the maintenance of sinus rhythm in paroxysmal atrial fibrillation patients.
- Trial name
- NCT00540787
- Testing
- Radiofrequency ablation, antiarrhythmic drugs, Amiodarone, flecainide, propafenone, quinidine, dofetilide, sotalol, cibenzoline, beta blocking and calcium channel blocking agents and antiarrhythmic drugs, ThermoCool Radiofrequency Catheter
- Where
- 6 sites in United States, France and 1 more
- Volunteers
- 112 people
- Sponsor
- Biosense Webster, Inc.
Atrial Fibrillation (AF), Atrial Arrhythmia
A Study of the TactiFlex SE Catheter and Volt PFA Generator in Subjects With PAF:
The objective of this clinical study is to demonstrate that ablation with the TactiFlex SE Ablation catheter, in conjunction with a compatible pulsed field ablation (PFA) and/or radio frequency (RF) generator, is safe and…
- Conditions
- Atrial Fibrillation (AF), Atrial Arrhythmia, Paroxysmal AF, Drug Refractory Paroxysmal Atrial Fibrillation
- Trial name
- FlexPulse IDE (NCT06676072)
- Testing
- PFA Ablation catheter
- Where
- 32 sites in United States, Austria and 2 more
- Volunteers
- 188 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation (AF), Paroxysmal AF
PulseMagic™ TrueForce™ PAF NMPA Study
This clinical investigation is intended to demonstrate safety and effectiveness of the PulseMagic™ TrueForce™ Ablation Catheter and the PulseMagic™Pulse Field Ablation (PFA) Generator, and Columbus™ 3D EP Navigation System with…
- Conditions
- Atrial Fibrillation (AF), Paroxysmal AF, Drug Refractory Paroxysmal Atrial Fibrillation, Atrial Arrhythmia
- Trial name
- PFATrueForce (NCT07720557)
- Testing
- PFA Ablation catheter
- Where
- China
- Volunteers
- 150 people
- Sponsor
- Shanghai MicroPort EP MedTech Co., Ltd.
Atrial Fibrillation
STAR-AF:Substrate Versus Trigger Ablation for Reduction of Atrial Fibrillation Trial
Patient Population: Patients with AF that is symptomatic and refractory to at least one antiarrhythmic medication. Patients must have AF that is paroxysmal (>4 episodes within 6 months, two episodes >6 hours within 1 year) or…
- Trial name
- NCT00367757
- Testing
- Ablate AF triggers via PVI, Substrate via CFAEs, Combined approach for AF ablation
- Where
- 8 sites in Canada, Italy and 2 more
- Volunteers
- 107 people
- Sponsor
- Abbott Medical Devices
Persistent Atrial Fibrillation, Paroxysmal Atrial Fibrillation
Randomized Evaluation of Redo Ablation Procedures of Atrial Fibrillation With FIRM Guided Procedures
A prospective, multicenter, randomized study to assess the safety and effectiveness of FIRM-guided procedures in conventional "redo" RF ablation procedures for the treatment of persistent and paroxysmal atrial fibrillation.
- Trial name
- REDO-FIRM (NCT02799043)
- Testing
- Standard PVI, FIRM-Guided Procedure and PVI
- Where
- 24 sites in United States, Belgium and 2 more
- Volunteers
- 269 people
- Sponsor
- Abbott Medical Devices
Paroxysmal Atrial Fibrillation
THERMOCOOL SMARTTOUCH®SF Catheters With Ablation Index Study
A single-center, real word study of consecutive subjects who undergo radiofrequency ablation for paroxysmal AF using THERMOCOOL SMARTTOUCH®SF (STSF) Catheter guiding by Ablation Index (AI).
- Trial name
- STSF (NCT03963349)
- Where
- China
- Volunteers
- 150 people
- Sponsor
- Biosense Webster, Inc.
Heart Diseases, Arrhythmia
THERMOCOOL® SMARTTOUCH™ Catheter for the Treatment of Symptomatic Paroxysmal Atrial Fibrillation
The purpose of this study is to demonstrate the safety and effectiveness of the THERMOCOOL® SMARTTOUCH™ Catheters with Contact Force Sensing Capability in the treatment of drug refractory symptomatic paroxysmal Atrial…
- Conditions
- Heart Diseases, Arrhythmia, Atrial Fibrillation
- Trial name
- NCT01385202
- Testing
- THERMOCOOL® SMARTTOUCH™ Catheter
- Volunteers
- 172 people
- Sponsor
- Biosense Webster, Inc.
Atrial Fibrillation
Clinical Study for Workflow and Performance Evaluation of the THERMOCOOL SMARTTOUCH® SF-5D System for Treating Symptomatic Paroxysmal AF (QDOT-Micro)
The QDOT-Micro study is a prospective, multi-center, non-randomized, interventional clinical study.
- Trial name
- NCT02944968
- Testing
- THERMOCOOL SMARTTOUCH® SF-5D catheter
- Volunteers
- 51 people
- Sponsor
- Biosense Webster, Inc.
Paroxysmal Atrial Fibrillation (PAF)
A Clinical Study on the Use of a Domestically Produced Cryoablation System Combined With Balloon Cryoablation Technology for the Treatment of Paroxysmal Atrial Fibrillation
To validate the safety and efficacy of balloon cryoablation technology and the accompanying disposable intracardiac mapping electrode catheter and adjustable guide sheath for the treatment of paroxysmal atrial fibrillation.
- Trial name
- Balloon cryoab (NCT07036068)
- Testing
- IceMagic™ CryoAblation Catheter
- Where
- China
- Volunteers
- 20 people
- Sponsor
- Shanghai MicroPort EP MedTech Co., Ltd.
Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation
A Study Assessing Arrhythmia Mapping With a Globe-Shaped, High-Density, Multi-Electrode Mapping Catheter
The purpose of this study is to assess the performance and safety for the use of the investigational catheter for intracardiac mapping in the atria and ventricles.
- Conditions
- Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation, Paroxysmal Atrial Fibrillation, Ventricular Tachycardia
- Trial name
- COSMOS (NCT05373862)
- Testing
- Globe-Shaped, High-Density, Multi-Electrode Mapping Catheter
- Where
- 4 sites in Belgium, Croatia and 1 more
- Volunteers
- 40 people
- Sponsor
- Biosense Webster, Inc.