Clinical trials: Proximal Humeral Fracture
Humerus Fracture, Humerus
RSA vs. Nonop for 3 & 4-Part Proximal Humerus Fractures
There is currently no consensus amongst orthopedic specialists on the best way to treat 3- and 4-part proximal humerus fractures.
- Conditions
- Humerus Fracture, Humerus, Shoulder Fractures, Shoulder Arthropathy Associated With Other Conditions
- Trial name
- NCT03599336
- Testing
- Reverse Total Shoulder Arthroplasty (rTSA), Nonoperative Treatment
- Where
- United States
- Volunteers
- 4 people
- Sponsor
- Mayo Clinic
Humeral Fractures, Proximal
Treatment of Proximal Humeral Fractures
This trial is designed to compare head-to-head conservative with operative treatment in 2 stratum. Stratum 1: In 2 part fractures the comparison is between conservative treatment and operative treatment with plate fixation with…
- Trial name
- TPHF (NCT01246167)
- Testing
- Philos, Epoca, Control group
- Where
- 6 sites in Denmark, Estonia and 2 more
- Volunteers
- 250 people
- Sponsor
- Tampere University Hospital
Humeral Fractures, Proximal
Post-Approval Prospective Study - Conventus CAGE™ PH for Use in Proximal Humerus Fracture Fixation
The purpose of this study is to collect device and procedure experience in everyday clinical practice. The patients are being asked to participate in this study because they are a surgical candidate for the treatment of a broken…
- Trial name
- NCT03489408
- Testing
- Conventus Cage™ PH
- Where
- 5 sites in United States
- Volunteers
- 40 people
- Sponsor
- Conventus Orthopaedics, Inc.
Anterior Shoulder Dislocation, Bankart Lesion
Dynamic Anterior Stabilization With Transsubscapular Long Head of the Biceps
Clinical study of patients with a history of traumatic anterior shoulder dislocations to test the hypothesis that the arthroscopic dynamic anterior capsular stabilization technique with trans subscapular long head of the biceps…
- Conditions
- Anterior Shoulder Dislocation, Bankart Lesion, Hill Sachs Lesion
- Trial name
- NCT03693716
- Testing
- Dynamic Anterior Stabilization
- Where
- Portugal
- Volunteers
- 18 people
- Sponsor
- Hospital de Egas Moniz
Proximal or Diaphyseal Humerus Fracture, Diaphyseal or Distal Femur Fracture
Observational Patient Registry of the Dynamic Locking Screws
The purpose of this multi-center patient registry is to obtain first clinical results and to assess short and mid-term clinical outcome data of patients treated with DLS.
- Conditions
- Proximal or Diaphyseal Humerus Fracture, Diaphyseal or Distal Femur Fracture, Diaphyseal, Distal or Proximal Tibia Fracture
- Trial name
- DLS (NCT02656628)
- Testing
- Dynamic Locking Screw 3.7mm and 5.0mm
- Where
- Australia
- Sponsor
- Synthes GmbH
Shoulder Fractures
Targon PH+ Follow-Up
With this study results of the Targon® PH+ nail, developed for the treatment of humeral head fractures, will be investigated clinically, radiological evaluation is optional.
- Trial name
- NCT02836366
- Where
- Germany
- Volunteers
- 50 people
- Sponsor
- Aesculap AG
Proximal Humerus Fractures (to be Managed Non-operatively)
Cross-education for Proximal Humerus Fracture Rehabilitation
Proximal humerus fractures (break of the top part of the upper arm bone) are common in older people with poorer bone quality. Often patients do not undergo surgery for these fractures: the bone fragments may be in an acceptable…
- Trial name
- NCT03017105
- Testing
- Cross-education of strength-training, Usual rehabilitation
- Volunteers
- 40 people
- Sponsor
- Liverpool University Hospitals NHS Foundation Trust
Shoulder Pain, Shoulder Injuries
MDR - Comprehensive Reverse/Versa Dial Ti Glenosphere
The objective of this retrospective/prospective consecutives series PMCF study is to collect data confirming safety, performance and clinical benefits of the Comprehensive Versa-Dial Reverse Ti Glenosphere when used for primary…
- Conditions
- Shoulder Pain, Shoulder Injuries, Shoulder Fractures, Shoulder Arthritis
- Trial name
- NCT04003272
- Testing
- Comprehensive Reverse Versa-Dial Titanium Glenosphere
- Where
- 2 sites in United States
- Volunteers
- 59 people
- Sponsor
- Zimmer Biomet
Proximal Humeral Fracture
Paravertebral Block for Proximal Humeral Fracture Surgery
This study evaluates the effects of T2 paravertebral block block improving interscalene brachial plexus block and superficial cervical plexus block on the relief of pain intensity during elderly proximal humerus fracture fixation…
- Trial name
- NCT03919422
- Testing
- T2 paravertebral block, interscalene brachial plexus block and superficial cervical plexus block
- Where
- China
- Volunteers
- 80 people
- Sponsor
- Shanghai 6th People's Hospital
Humerus Fracture Displaced Proximal
Cell Therapy by Autologous BMC for Large Bone Defect Repair
In the present phase-II clinical trial the researchers investigate efficacy and proof of concept of the augmentation with preoperatively isolated autologous BMC cells seeded onto ß-TCP in combination with an angle stable fixation…
- Trial name
- BMC2012 (NCT02803177)
- Testing
- BMC2012, beta-TCP Chronos® Synthes
- Where
- Germany
- Volunteers
- 55 people
- Sponsor
- Goethe University
Other Instability, Shoulder, Hill-Sachs Lesion
Arthroscopic Bankart Repair With and Without Remplissage in Anterior Shoulder Instability
The purpose of this prospective, randomized, controlled trial is to compare subjective patient-reported outcomes and objective clinical results between arthroscopic Bankart repair with and without arthroscopic infraspinatus…
- Trial name
- NCT01324531
- Testing
- Bankart repair and remplissage, Bankart repair
- Where
- 2 sites in Canada
- Volunteers
- 150 people
- Sponsor
- Panam Clinic
Humerus Fracture, Femur Fracture
Evaluation of Handling and Possible Complications Related to the Newly Developed Angular Stable Locking System (ASLS)
In many cases, the existing locking bolts and screws in intramedullary nails do not provide sufficient stability. Due to the play between screw and nail, the reduction can be lost and the instability can result in malunions…
- Conditions
- Humerus Fracture, Femur Fracture, Tibia Fracture
- Trial name
- ASLS-Pre (NCT00793637)
- Where
- 4 sites in Austria, Germany
- Volunteers
- 30 people
- Sponsor
- AO Clinical Investigation and Publishing Documentation
Humerus, Proximal Humeral Fracture
Proximal Humerus Fractures: Randomized Study Between Locking Nails and Locking Plates for Neer 2 and 3 Parts
The hypothesis of this study is to determine whether the technique of intramedullary locking nail presents clinical results comparable to the technique of locking plates, based on the Constant Score.
- Conditions
- Humerus, Proximal Humeral Fracture, Fractures, Bone, Humeral Fractures
- Trial name
- NCT01984112
- Testing
- Locked plate, Intramedullary locked nail
- Where
- Brazil
- Volunteers
- 72 people
- Sponsor
- University of Sao Paulo
Osteoarthritis, Avascular Necrosis
Post-market Surveillance Study With the HYPERION Hip Endoprosthesis System in Defect Reconstruction
The study is a multi-center, prospective, non-controlled, consecutive cohort post market surveillance study. The objective of this study is to obtain survival and clinical outcome data on the Hyperion® system in primary and…
- Conditions
- Osteoarthritis, Avascular Necrosis, Rheumatoid Arthritis, Functional Deformities
- Trial name
- NCT03382665
- Where
- 3 sites in Germany
- Volunteers
- 70 people
- Sponsor
- Zimmer Biomet
A02.835.232.087.090.400.400
Effectiveness Between Two Surgical Techniques for Reconstruction of Humeral Proximal Extremity Fractures
The purpose of this study is to evaluate the effectiveness and safety of two surgical techniques for the treatments of proximal extremity humeral fractures and fractures luxation in three o four fragments of Neer's classification.
- Trial name
- NCT02075476
- Testing
- Hemiarthroplasty, reverse arthroplasty
- Where
- Spain
- Volunteers
- 40 people
- Sponsor
- Carlos Alvarez
Orthopedic Disorder, Humerus Fracture
Early Versus Delayed Rehabilitation After Reverse Total Shoulder Arthroplasty for Proximal Humerus Fracture
Proximal humerus fractures can be a debilitating injury in the elderly, impacting the ability to function independently or complete activities of daily living due to pain and restricted shoulder motion.
- Conditions
- Orthopedic Disorder, Humerus Fracture, Shoulder Arthroplasty, Reverse Shoulder Replacement
- Trial name
- NCT06869343
- Testing
- Physical Therapy
- Where
- United States
- Volunteers
- 10 people
- Sponsor
- University of Virginia
Closed Fracture Proximal Humerus, Neck
Lateral Mini Approach vs Anterior Approach for Plating of Proximal Humerus Fracture
A prospective randomized clinical trial is proposed to compare the plate fixation of proximal humerus fractures using a minimally invasive lateral approach and the traditional anterior approach.Forty five patients will be…
- Trial name
- HURA (NCT00612391)
- Testing
- Lateral minimally invasive approach (plate fixation), Deltopectoral approach (plate fixation)
- Where
- Canada
- Volunteers
- 79 people
- Sponsor
- Université de Montréal
Proximal Humeral Fracture
Evidence Based Algorithm for Proximal Humerus Fractures
Proximal humerus fractures are particularly frequent injuries and represent 6% of all fractures with an overall incidence of 63/100.000 in human.
- Trial name
- NCT03464578
- Testing
- Therapy of proximal humeral fractures (irrespective conservative or operative)
- Where
- Switzerland
- Volunteers
- 143 people
- Sponsor
- Cantonal Hospital of St. Gallen
Proximal Humeral Fracture
Assessment of the Surgical Handling and Performance of the X-ray-based Tracking and Navigation System "Xin1 Humerus System" Evaluated From 10 Proximal Humerus Plate Fixations
Xin1 Humerus system is an X-ray-based tracking and navigation system designed to calculate the plate position and all required proximal screw lengths for proximal humerus plate fixation.
- Trial name
- NCT03427112
- Testing
- Xin1 Humerus System
- Where
- Belgium
- Volunteers
- 11 people
- Sponsor
- AO Research Institute Davos
Shoulder Fractures
Conservative vs Surgical Treatment for Proximal Humerus Fractures in the Elderly
This is a randomized trial comparing conservative with surgical treatment (with open reduction and locking plate fixation) for proximal humeral fractures in patients aged more than 60 years.
- Trial name
- NCT02913378
- Testing
- Osteosynthesis with locking plate, Sling
- Where
- Brazil
- Volunteers
- 58 people
- Sponsor
- University of Sao Paulo