Clinical trials: Sudden Cardiac Arrest
Cardiac Arrest, Sudden
ASSURE WCD Clinical Evaluation - Detection and Safety Study
A prospective multicenter single arm open label study to evaluate ambulatory detection performance, arrhythmia detection and safety of the ASSURE™ Wearable Cardioverter Defibrillator (WCD).
- Trial name
- ACE-DETECT (NCT03887052)
- Testing
- ASSURE™ Wearable Cardioverter Defibrillator (WCD)
- Where
- 10 sites in United States
- Volunteers
- 130 people
- Sponsor
- Kestra Medical Technologies, Inc.
Coronary Artery Disease, Left Ventricular Dysfunction
DEfibrillators To REduce Risk by MagnetIc ResoNance Imaging Evaluation
This trial is a prospective, multi-center, randomized study of patients with coronary artery disease (CAD) and mild to moderate left ventricular (LV) dysfunction.
- Conditions
- Coronary Artery Disease, Left Ventricular Dysfunction, Sudden Cardiac Death
- Trial name
- DETERMINE (NCT00487279)
- Testing
- Defibrillator, Control
- Where
- 56 sites in United States
- Volunteers
- 81 people
- Sponsor
- Abbott Medical Devices
Cardiac Arrest, Sudden Death
A Comparative Study Between a Pre-hospital and an In-hospital Circulatory Support Strategy (ECMO) in Refractory Cardiac Arrest (APACAR2)
Cardiac arrest (CA) affects approximately 40,000 people in France. It is still a major cause of death in a young population. Management of CA is defined by international recommendations, detailed by learned societies in each…
- Trial name
- APACAR2 (NCT02527031)
- Testing
- ECMO Insertion on pre hospital setting, In Hospital ECMO
- Where
- France
- Volunteers
- 65 people
- Sponsor
- Assistance Publique - Hôpitaux de Paris
Cardiac Arrest, Sudden Cardiac Arrest
Coenzyme Q10 in Post-Cardiac Arrest Cerebral Resuscitation
Specific Aim #1: To determine if levels of CoQ10 are low post-cardiac arrest (CA). We will perform a prospective trial with the primary endpoint of describing the prevalence of low serum CoQ10 levels.
- Trial name
- NCT01319110
- Testing
- Coenzyme Q10
- Where
- United States
- Volunteers
- 10 people
- Sponsor
- Beth Israel Deaconess Medical Center
Left Ventricular Systolic Dysfunction, Sudden Cardiac Death
Heart Rate Response to Regadenoson and Sudden Cardiac Death
The purpose of this study is to determine whether a blunted heart rate response to regadenoson is an independent predictor of sudden cardiac death.
- Trial name
- NCT01842035
- Testing
- regadenoson
- Where
- United States
- Volunteers
- 90 people
- Sponsor
- University of Alabama at Birmingham
Death, Sudden, Cardiac, Out-Of-Hospital Cardiac Arrest
Pre-hospital ECMO in Advanced Resuscitation in Patients With Refractory Cardiac Arrest. ( SUB30 )
To establish whether a pre-hospital advanced physician/ paramedic cardiac arrest team that is ECMO capable can establish ECMO flow within 30 minutes of collapse.
- Conditions
- Death, Sudden, Cardiac, Out-Of-Hospital Cardiac Arrest, Ventricular Fibrillation, Cardiopulmonary Arrest With Successful Resuscitation
- Trial name
- SUB30 (NCT03700125)
- Testing
- ECMO resuscitation
- Where
- 2 sites in United Kingdom
- Volunteers
- 5 people
- Sponsor
- Barts & The London NHS Trust
Cardiac Arrest, Sudden Cardiac Death
Treatment of Ventricular Tachyarrhythmias Refractory To Shock With Beta Blockers: The SHOCK and BLOCK Trial
The purpose of this research study is to evaluate the effectiveness of metoprolol, a "beta blocker," in treating patients in the hospital with a cardiac arrest. It will be given intravenously (given into a vein).
- Conditions
- Cardiac Arrest, Sudden Cardiac Death, Ventricular Fibrillation, Tachycardia, Ventricular
- Trial name
- Shock n Block (NCT00401882)
- Testing
- Epinephrine, Metoprolol
- Where
- United States
- Volunteers
- 7 people
- Sponsor
- David Haines, MD
Ventricular Tachycardia (VT)
Pan-Asia United States PrEvention of Sudden Cardiac Death Catheter Ablation Trial
The current standard of care for ventricular tachycardia (VT) includes the use of medicine called anti-arrhythmic drugs (AADs) and Implantable Cardioverter Defibrillator (ICD) therapy.
- Trial name
- PAUSE-SCD (NCT02848781)
- Testing
- Implantable Cardioverter Defibrillator (ICD), Catheter Ablation
- Where
- 12 sites in United States, China and 3 more
- Volunteers
- 180 people
- Sponsor
- University of Arizona