Clinical trials: Sudden Cardiac Death
Arrhythmias, Cardiac
Evaluating the Risk of Serious Ventricular Arrhythmia and Sudden Cardiac Death Among Users of Domperidone
The purpose of this retrospective observational study is to obtain information to confirm or contradict the results of prior studies on domperidone and sudden cardiac death.
- Trial name
- NCT00925457
- Testing
- No Intervention, Current Domperidone, Current proton pump inhibitor (PPI)
- Volunteers
- 1,608 people
- Sponsor
- Johnson & Johnson Pharmaceutical Research & Development, L.L.C.
Ventricular Tachycardia, Ventricular Fibrillation
DF4 Master Study (Safety and Efficacy Study)
The purpose of the study is to proof the safety and efficacy of the new ICD sytem (Iforia/Ilesto). The devices are available with DF-1 and DF4 connection. A special focus is set on the ICD system with DF4 connection.
- Conditions
- Ventricular Tachycardia, Ventricular Fibrillation, Sudden Cardiac Death, Heart Failure
- Trial name
- NCT01790841
- Testing
- Iforia/Ilesto ICD/CRT-D, Linox smart DF4 lead/ Protego
- Where
- Germany
- Volunteers
- 240 people
- Sponsor
- Biotronik SE & Co. KG
Cardiac Arrest, Sudden
AED Log Analysis of 19 Cases in Out-of-hospital Environment
The study performed to demonstrate a reasonable assurance of safety and effectiveness of the Heart Guardian HR-501 when used in an out-of-hospital environment.
- Trial name
- NCT03969797
- Testing
- RADIAQBIO Heart Guardian HR-501
- Where
- South Korea
- Volunteers
- 19 people
- Sponsor
- RadianQbio
Sudden Cardiac Death, Sudden Cardiac Arrest
Time and Dose Evaluation of Stearidonic Acid (SDA) to Eicosapentaenoic Acid (EPA) in Red Blood Cells
The purpose of this study is to assess the relationships between dose and time of consumption of stearidonic acid (SDA) and eicosapentaenoic acid (EPA) on EPA enrichment of red blood cell (RBC) membranes in men and women.
- Conditions
- Sudden Cardiac Death, Sudden Cardiac Arrest, Cardiovascular Disease
- Trial name
- NK (NCT01038440)
- Testing
- Safflower Oil, EPA, SDA
- Volunteers
- 137 people, healthy volunteers welcome
- Sponsor
- Solae, LLC
Sudden Cardiac Death
Predictive Risk Stratification Through T Variability in ICD Patients Without Pacing Indications
The aim of the study is to assess the negative predictive value of the T amplitude variance as a method for risk stratification for patients with an increased risk for SCD.
- Trial name
- Prediction (NCT00560768)
- Testing
- Ovatio VR 6250 or DR6550
- Where
- 30 sites in United States, Canada and 2 more
- Volunteers
- 198 people
- Sponsor
- LivaNova
Heart Failure, Arrhythmias, Cardiac
Heart Failure and Sudden Cardiac Death Japan Registry
The purpose of this observational registry is to collect clinical events and outcome data in 4 different study populations (cohorts), with a majority of Japanese subjects, that are at risk of sudden cardiac death (SCD) and heart…
- Conditions
- Heart Failure, Arrhythmias, Cardiac, Sudden Cardiac Death
- Trial name
- HINODE (NCT03185832)
- Testing
- CRT-D, ICD, PM / CRT-P
- Where
- 34 sites in Japan
- Volunteers
- 354 people
- Sponsor
- Boston Scientific Corporation
Heart Arrest, Death, Sudden, Cardiac
ResQ Trial: Impact of an ITD and Active Compression Decompression CPR on Survival From Out-of-Hospital Cardiac Arrest
The purpose of this study is to determine whether performing active compression decompression cardiopulmonary resuscitation (ACD-CPR) with an impedance threshold device (ITD) compared to conventional standard cardiopulmonary…
- Conditions
- Heart Arrest, Death, Sudden, Cardiac, Cardiopulmonary Resuscitation, Cardiac Arrest
- Trial name
- ResQ (NCT00189423)
- Testing
- Use of an impedance threshold device (ITD) during the performance of active compression decompression CPR (ACD-CPR), Standard cardiopulmonary resuscitation (S-CPR)
- Where
- 7 sites in United States
- Volunteers
- 1,653 people
- Sponsor
- Advanced Circulatory Systems
Heart Failure, Sudden Cardiac Death
CORE: Study to Evaluate the Conducted AF-Response-Algorithm in Patients Suffering From Heart Failure and Atrial Fibrillation
The Medtronic InSync III Marquis Cardiac Resynchronization Therapy Defibrillator (CRT-D)-System (implantable cardioverter-defibrillator with biventricular stimulation for cardiac resynchronization) is equipped with the…
- Conditions
- Heart Failure, Sudden Cardiac Death, Atrial Fibrillation
- Trial name
- NCT00170313
- Testing
- Conducted AF-Response Algorithm (CAFR) On, Conducted AF-Response Algorithm (CAFR) Off
- Where
- 7 sites in Germany
- Volunteers
- 100 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Sudden Cardiac Arrest, Acute Myocardial Infarction
Improve SCA Bridge Study
The purpose of the Improve SCA Bridge study is to characterize the care pathway flow of post-acute myocardial infarction (MI) patients as a result of standard assessments of left ventricular ejection fraction (LVEF) in the acute…
- Trial name
- NCT03715790
- Testing
- EP referred group, Non-Referred group
- Where
- 52 sites in Bangladesh, Brunei and 14 more
- Volunteers
- 1,491 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure