Clinical trials: Tricuspid Insufficiency
Tricuspid Regurgitation Functional
Early Feasibility Study of the Cardiac Implants Percutaneous Ring Annuloplasty System
An early feasibility study to evaluate the safety and performance of 1) the transcatheter delivery and implantation of the Cardiac Implants (CI) annuloplasty ring and 2) the adjustment of the ring approximately 90 days following…
- Trial name
- NCT04890821
- Testing
- CI Percutaneous Ring Annuloplasty System
- Where
- 2 sites in United States
- Volunteers
- 15 people
- Sponsor
- Cardiac Implants LLC
Tricuspid Regurgitation
TTVR Early Feasibility Study
The objective of this early feasibility study is to gain early clinical insight into the performance of the Intrepid transcatheter tricuspid valve replacement (TTVR) system intended for transfemoral access to deliver a…
- Trial name
- NCT04433065
- Testing
- Intrepid™ TTVR System
- Where
- 20 sites in United States
- Volunteers
- 150 people
- Sponsor
- Medtronic Cardiovascular
Tricuspid Regurgitation
Early Phase Study Using the 'Pivot Extend' System as a Treatment for Patients With Tricuspid Regurgitation
Participants with severe tricuspid regurgitation may require heart surgery to repair or replace the tricuspid valve. However, there is a high risk associated with these surgeries and it is often not feasible for elderly patients…
- Trial name
- SPACER (NCT07172477)
- Testing
- Pivot Extend
- Where
- Australia
- Volunteers
- 10 people
- Sponsor
- Tau Medical Australia Pty Ltd
Functional Tricuspid Regurgitation (TR)
First in Human Study of the DaVingi™ TR System in the Treatment of Patients With Functional Tricuspid Regurgitation
The DaVingi™ System is a percutaneous trans-catheter device delivered using right heart catheterization through the right internal jugular vein.
- Trial name
- NCT03700918
- Testing
- DaVingiTR System
- Where
- 5 sites in Czechia, France and 1 more
- Volunteers
- 15 people
- Sponsor
- Cardiac Implants LLC
Tricuspid Regurgitation
The TRICURE First in Human Trial
The objective of this first in human study is to gain early clinical insight into the safety profile and performance of the Topaz transcatheter tricuspid valve replacement (TTVR) system intended for transfemoral access to deliver…
- Trial name
- TRICURE (NCT05126030)
- Testing
- Topaz TTVR System
- Where
- 11 sites in Belgium, France
- Volunteers
- 20 people
- Sponsor
- TRiCares
Tricuspid Regurgitation Functional, Tricuspid Regurgitation
The STTAR-US Study: A Pivotal Study of Transcatheter Tricuspid Annular Repair in the US
Purpose of this clinical study is to demonstrate the safety and efficacy of MIA-T system in improving clinical outcomes in symptomatic patients with severe tricuspid regurgitation (TR grade ≥3) despite optimal medical therapy…
- Conditions
- Tricuspid Regurgitation Functional, Tricuspid Regurgitation, Severe Tricuspid Valve Regurgitation
- Trial name
- STTAR-US (NCT06700239)
- Testing
- MIA_T Device
- Volunteers
- 600 people
- Sponsor
- Micro Interventional Devices
Functional Tricuspid Regurgitation
Evaluation of Safety and Efficacy of Pivot Balloon to Monitoring Acute RV Failure and Reduction of FTR
Pivot Balloon to monitoring acute RV failure and reduction of Functional Tricuspid Regurgitation
- Trial name
- NCT05648838
- Testing
- Pivot Balloon Catheter
- Where
- 10 sites in South Korea
- Volunteers
- 7 people
- Sponsor
- Tau-MEDICAL Co., Ltd.
Severe Tricuspid Regurgitation
TRICUS STUDY Euro - Safety and Efficacy of the TricValve® Device
The TricValve® Transcatheter Bicaval Valves System is indicated for relief of tricuspid insufficiency in patients with symptomatic heart disease who are judged by a heart team, including a cardiac surgeon, to be at extreme risk…
- Trial name
- NCT04141137
- Testing
- TricValve® System
- Where
- 10 sites in Austria, Spain
- Volunteers
- 35 people
- Sponsor
- P+F Products + Features GmbH
Tricuspid Valve Regurgitation, Heart Valve Disease
The TRICURE EU Pivotal Study
Prospective, multi-center study to assess safety and performance of the TRiCares Topaz Tricuspid Valve Replacement System
- Conditions
- Tricuspid Valve Regurgitation, Heart Valve Disease, Cardiovascular Diseases
- Trial name
- TRICURE EU (NCT06581471)
- Testing
- Transcatheter Tricuspid Valve Replacement
- Where
- 8 sites in Belgium, Germany
- Volunteers
- 80 people
- Sponsor
- TRiCares
Functional Tricuspid Regurgitation
The Study for Evaluation of Acute Phase Safety and Efficacy of 'Pivot Bridge' to Short-term Treat FTR
evaluation of safety and efficacy of 'Pivot Bridge' to short-term treat Functional Tricuspid regurgitation
- Trial name
- NCT05854095
- Testing
- Pivot Bridge
- Where
- 10 sites in South Korea
- Volunteers
- 15 people
- Sponsor
- Tau-MEDICAL Co., Ltd.
Tricuspid Regurgitation, Tricuspid Valve Disease
Clinical Safety and Efficacy of the VDyne Transcatheter Tricuspid Valve Replacement System for the Treatment of Tricuspid Regurgitation
The purpose of this clinical study is to collect safety and efficacy data of the VDyne System to support Conformitè Europëenne (CE) Mark of the VDyne System.
- Conditions
- Tricuspid Regurgitation, Tricuspid Valve Disease, Tricuspid Valvular Disorders
- Trial name
- VISTA (NCT05797519)
- Testing
- VDyne Transcatheter Tricuspid Valve Replacement System
- Where
- 21 sites in Australia, Austria and 9 more
- Volunteers
- 120 people
- Sponsor
- VDyne, Inc.
Tricuspid Regurgitation, Tricuspid Valve Insufficiency
Edwards PASCAL Transcatheter Valve Repair System Pivotal Clinical Trial
To establish the safety and effectiveness of the Edwards PASCAL Transcatheter Repair System in patients with symptomatic severe tricuspid regurgitation who have been determined to be at an intermediate or greater estimated risk…
- Conditions
- Tricuspid Regurgitation, Tricuspid Valve Insufficiency, Tricuspid Valve Disease
- Trial name
- CLASP II TR (NCT04097145)
- Testing
- Edwards PASCAL System, Optimal Medical Therapy
- Where
- 79 sites in United States, Canada
- Volunteers
- 1,270 people
- Sponsor
- Edwards Lifesciences
Tricuspid Regurgitation (TR)
TraNsvenous TrIcuspid Valve ReplacemenT With LuX-Valve Plus System (TRINITY-US)
The LuX-Valve Plus System is intended for the treatment of patients with at least severe TR who are symptomatic and determined by a Heart Team not to be suitable for surgical treatment.
- Trial name
- NCT06568003
- Testing
- Transcatheter Tricuspid Valve Intervention
- Where
- 3 sites in United States
- Volunteers
- 15 people
- Sponsor
- Jenscare Innovation Inc.
Tricuspid Valve Insufficiency
EASE TRICUSPID Expertise-based Assessment Study on Clinical Efficacy of Contour 3D® in TRICUSPID Valve Annuloplasty
Few clinical evidence for the Contour 3D Tricuspid Annuloplasty Ring exists; therefore, in order to position this product on the market, a post-market release study was completed.
- Trial name
- NCT01532921
- Testing
- Tricuspid valve repair, Left-sided heart surgery, Contour 3D Tricuspid Annuloplasty Ring
- Where
- 7 sites in France, Germany and 1 more
- Volunteers
- 85 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Tricuspid Regurgitation
Percutaneous Treatment of Tricuspid Valve Regurgitation With the TriCinch System™
The TriCinch System™ is intended for percutaneous treatment of tricuspid regurgitation. It is a percutaneous catheter-based device designed for tricuspid valve repair in order to decrease effective cross-sectional area and…
- Trial name
- PREVENT (NCT02098200)
- Testing
- TriCinch System
- Where
- 14 sites in France, Germany and 2 more
- Volunteers
- 24 people
- Sponsor
- 4Tech Cardio Ltd.
Tricuspid Valve Insufficiency
TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR
The primary purpose of this study is to evaluate safety and effectiveness of the Tricuspid Valve Repair System (TVRS) for treating symptomatic moderate or greater tricuspid regurgitation (TR) in patients currently on medical…
- Trial name
- TRILUMINATE (NCT03227757)
- Testing
- Tricuspid Valve Repair System
- Where
- 20 sites in United States, France and 4 more
- Volunteers
- 98 people
- Sponsor
- Abbott Medical Devices
Mitral Regurgitation, Tricuspid Regurgitation
Annuloplasty Rings and Band Post-Market Clinical Follow-Up Study
ARB-PMCF is a multicenter, observational study of the safety and performance of Abbott annuloplasty devices used in surgical repair of mitral and tricuspid valve regurgitation.
- Conditions
- Mitral Regurgitation, Tricuspid Regurgitation, Valvular Heart Disease
- Trial name
- ARB-PMCF (NCT04761120)
- Testing
- Abbott SJM Rigid Saddle Ring, Abbott SJM Séguin Ring, Abbott SJM Tailor Ring
- Where
- 17 sites in United States, Estonia and 5 more
- Volunteers
- 550 people
- Sponsor
- Abbott Medical Devices
Murmur, Heart, Aortic Valve Stenosis
Development of an Algorithm to Differentiate Heart Murmurs Using Electronic Stethoscopes
The Eko CORE and DUO stethoscopes are FDA-approved electronic devices that have the capacity to record heart sounds. The study seeks to expand murmur detection to include VHD classification through the development of novel ML…
- Conditions
- Murmur, Heart, Aortic Valve Stenosis, Tricuspid Regurgitation, Mitral Regurgitation
- Trial name
- NCT04400513
- Testing
- Use of Eko CORE and Eko DUO electronic stethoscopes
- Where
- United States
- Volunteers
- 1,145 people
- Sponsor
- Eko Devices, Inc.
Tricuspid Valve Disease, Tricuspid Valve Insufficiency
CorMatrix Cor TRICUSPID ECM Valve Replacement - Pivotal Study
The goal of this pivotal study is to demonstrate the safety and performance of the Cor TRICUSPID ECM (extracellular matrix) Valve (or Cor PEDIATRIC Tricuspid ECM Valve) for the surgical management of tricuspid valve disease and…
- Trial name
- NCT05742906
- Testing
- Tricuspid valve replacement with the Cor TRICUSPID ECM Valve
- Where
- 2 sites in United States
- Volunteers
- 92 people
- Sponsor
- Corvivo Cardiovascular, Inc.
Tricuspid Valve Regurgitation, Heart Valve Diseases
The TRICURE EFS Study
Prospective, multi-center study to assess safety and performance of the TRiCares Topaz Tricuspid Valve Replacement System
- Conditions
- Tricuspid Valve Regurgitation, Heart Valve Diseases, Cardiovascular Diseases
- Trial name
- TRICURE EFS (NCT06506942)
- Testing
- Transcatheter Tricuspid Valve Replacement
- Where
- 10 sites in United States, Canada
- Volunteers
- 15 people
- Sponsor
- TRiCares