AzTrials
AzTrials

Wounds and InjuriesNCT00310999

C-Spine Movement - Shikani Optical Scope vs Macintosh Laryngoscope for Patients With Cervical Spine Injury

A study testing Shikani Optical Stylet in people with Wounds and Injuries, run by London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Patients undergoing surgery will have laryngoscopy performed using two widely accepted techniques - Macintosh Laryngoscope and Shikani Optical Scope. The techniques will be timed and compared for cervical spine movement using fluoroscopy. Read more about this study

Who is it for?
Ages 18 to 75 yearsHealthy volunteers can take part
Conditions the study is for
Wounds and Injuries
What is being tested?
Shikani Optical Stylet
Type of treatment
Medical device
How many people
24 participants
Where
1 siteCanada
Study dates
Mar 2006to Sep 2006
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Elective non-cardiac surgery patients requiring intubation for the surgery.
  • Age 18-75
  • ASA 1-3
  • Body Mass Index (BMI) < 40

Who cannot join

  • patients with previous neck surgery or unstable C-spine
  • patients with Reflux disease (GERD)
  • patients who are or may be pregnant

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • London Health Sciences Centre University Hospital Site

    London, Ontario, N6A 5A5

Other trials in Canada

About this study

Official title: Comparison of Shikani Optical Scope to Macintosh Laryngoscope for Intubation of Patients With Potential Cervical Spine Injury

Patients undergoing surgery will have laryngoscopy performed using two widely accepted techniques - Macintosh Laryngoscope and Shikani Optical Scope. The techniques will be timed and compared for cervical spine movement using fluoroscopy.

Read the detailed description

Approval for the study has been obtained from the Review Board for Health and Sciences Research Involving Human Subjects of the University of Western Ontario. Informed and written consent will be obtained from patients who are undergoing elective surgery requiring general anesthesia with endotracheal intubation. Preoperative clinical assessment of the patients will include routine airway evaluation of dentition, mouth opening, tongue size, Mallampati score, and neck mobility.

While awake, the patients will be placed on the operating room table with a rigid board under their head, neck, and torso in order to simulate the table on which patients involved in trauma are placed in the emergency room. In-line stabilization (ILS), as recommended by the ATLS guidelines, will be applied to maintain the patient's head in the neutral position and reduce neck movement during laryngoscopy.

After standard pre-oxygenation, anesthesia will be induced in routine fashion with 2-3 mg/kg propofol and 2-5 mcg/kg fentanyl; rocuronium 0.8 mg/kg will be administered to effect muscle paralysis. The patient will be then be ventilated with sevoflurane in 100% Oxygen via bag and mask for 3 minutes.

After the patient is anesthetized, a sealed envelope containing computer a generated random assignment will be opened. Laryngoscopy will then be performed two times, with the Macintosh laryngoscope and with the Shikani Optical Scope, in random order as determined by the envelope. Between laryngoscopies, the patient will be ventilated with sevoflurane in 100% Oxygen.

For direct Macintosh laryngoscopy, a size 3 laryngoscope blade will be recommended in all patients. With laryngoscopy, the glottis will be exposed to enable positioning of the endotracheal tube at the vocal cords. During the second laryngoscopy in the above sequence, the trachea will be intubated.

The study is then complete. The hard board will be removed and the surgery will proceed in the usual fashion.

The laryngoscopy and intubation will be recorded by a portable fluoroscopy unit for subsequent review by the radiologist to assess relative neck movement.

Laryngoscopy time will be defined as the time from when the laryngoscope blade or Shikani stylet passes the teeth of the patient until the time the endotracheal tube is positioned at the opening of the larynx. If the intubation sequence is longer than 120 seconds, it will be deemed a failure and recorded as such.

The Cormack (11) of the larynx will be recorded for all patients.

Being tested
Shikani Optical Stylet
Keywords
Cervical Vertebrae, Intubation, Intratracheal, Laryngoscopes, Fluoroscopy
Medical subject headings
Wounds and Injuries

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Shikani Optical StyletDevice

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. cervical spine movement

Secondary outcomes (1)
  1. Duration of intubation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Apr 2006 (estimated)
  2. Study startMar 2006
  3. Primary completionJun 2006
  4. Study completionSep 2006

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Enrolment
24 participants
IDs, dates and publications
ClinicalTrials.gov ID
NCT00310999
Sponsor's protocol ID
R-05-400
Other IDs
REB #: 11688, CRIC R-05-400
Status last verified
Nov 2018
First submitted
3 Apr 2006
Last updated
6 Nov 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Turkstra TP, Craen RA, Pelz DM, Gelb AW. Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope. Anesth Analg. 2005 Sep;101(3):910-915. doi: 10.1213/01.ane.0000166975.38649.27.

    PubMed 16116013
  • Sawin PD, Todd MM, Traynelis VC, Farrell SB, Nader A, Sato Y, Clausen JD, Goel VK. Cervical spine motion with direct laryngoscopy and orotracheal intubation. An in vivo cinefluoroscopic study of subjects without cervical abnormality. Anesthesiology. 1996 Jul;85(1):26-36. doi: 10.1097/00000542-199607000-00005.

    PubMed 8694378
  • Watts AD, Gelb AW, Bach DB, Pelz DM. Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury. Anesthesiology. 1997 Dec;87(6):1335-42. doi: 10.1097/00000542-199712000-00012.

    PubMed 9416718

Questions about this trial

What is this clinical trial studying?

A study testing Shikani Optical Stylet in people with Wounds and Injuries, run by London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Nov 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

cervical spine movement. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00310999, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Nov 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in