AzTrials
AzTrials

PediatricsNCT01043562

Precise Measurement of Pediatric Defibrillation Thresholds

An observational study of Pediatrics and Defibrillators, Implantable, run by Boston Children's Hospital at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Patients who receive an implantable cardioverter-defibrillator (ICD) usually undergo testing at the end of the ICD procedure to measure the amount of energy able to successfully defibrillate the heart (defibrillation threshold testing, or DFT). Read more about this study

Who is it for?
Any age
Conditions the study is for
Pediatrics, Defibrillators, Implantable
What is being tested?
Defibrillator threshold testing and Observation of post-shock intrinsic cardiac rhythm
Type of treatment
Injection or infusion
How many people
20 participants
Where
1 siteUnited States
Study dates
4 Jun 2009to 10 May 2012
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: All patients seen by the electrophysiology service at Children's Hospital Boston who are identified to be at very high risk of sudden cardiac death and in need of an ICD

Who may be able to join

  • Current follow-up at Children's Hospital Boston
  • Children with current or planned ICDs who are scheduled by their primary electrophysiologist for clinically necessary assessment/re-assessment of defibrillation threshold
  • If the patient has an ICD system with a non-transvenous shock coil: weight ≤35kg at time of initial implant, with current weight <50kg
  • If the patient has an ICD system with a conventional transvenous shock coil: current weight ≤60kg

Who cannot join

  • Clinical failure of any system component not able to be addressed by hardware repair or exchange
  • Hemodynamic instability that in the judgment of the primary electrophysiologist warrants abbreviation of DFT assessment
  • Unsuccessful induction of fibrillation during DFT testing

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Children's Hospital Boston

    Boston, Massachusetts, 02115

Other trials in United States

About this study

Official title: Defibrillation Thresholds in a Pediatric Cohort Using Binary Search Protocol

Patients who receive an implantable cardioverter-defibrillator (ICD) usually undergo testing at the end of the ICD procedure to measure the amount of energy able to successfully defibrillate the heart (defibrillation threshold testing, or DFT). This study proposes to perform that measurement in pediatric patients already undergoing clinically necessary ICD procedures, with the measurement performed using a binary search method that has been previously validated in adult cohorts. We hypothesize that pediatric DFTs, when precisely measured, may be lower than previously assumed from extrapolation of adult data.

Being tested
Defibrillator threshold testing, Observation of post-shock intrinsic cardiac rhythm

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Defibrillator threshold testingDiagnostic test

    Measurement of the defibrillation threshold was performed using a modified binary search protocol. This protocol specified three distinct inductions of ventricular fibrillation (VF) for all subjects, with a 3-5 minute observation/waiting period between inductions. The initial shock energy was programmed at 9 joules (J) for all patients, with internal rescue shocks at 31J followed by device-specific maximum deliverable energy. The outcome of the initial induction determined the programmed energies for both the initial and internal rescue shocks for the second induction, and likewise for the third induction. All shocks were biphasic and delivered at manufacturers' default tilt, polarity and duration, and all final programmed shock vectors included an active can. External defibrillation pads were in place for delivery of external rescue shock should the internal shocks fail.

  • Observation of post-shock intrinsic cardiac rhythmOther

    Prior to each of the three ventricular fibrillation inductions performed as part of the binary search protocol, post-shock pacing was re-programmed using a pre-determined, stepwise protocol that progressively decreased the lower rate limit. For the purpose of this protocol, post-shock pacing was considered necessary if 1) ≥7 ventricular-paced beats or 2) asystole >4 seconds was observed in the first 20 seconds after defibrillation, or if the systolic blood pressure demonstrated a >10% decrease from pre-induction baseline at follow-up measurement 1 minute post-defibrillation. Rescue ventricular pacing via the programmer was available for all subjects.

Study groups in NCT01043562
Study groupRoleWhat they receive
Pediatric ICD ptsInclusion criteria for study participants included: 1) weight ≤60 kg, 2) new or existing ICD system, and 3) clinically necessary assessment of the defibrillation efficacy of the ICD system. Transvenous systems utilized a high-voltage ICD coil with active-fixation lead attached to the right ventricular endocardial surface, whereas non-transvenous systems depended upon a high-voltage shocking coil placed within the pericardial, subcutaneous or pleural space. To be included in the post-shock pacing portion of the study, adequate sinus and AV node function had to be present at baseline. Exclusion criteria included 1) tenuous hemodynamic status felt to warrant abbreviation of the defibrillation efficacy testing or 2) inability to induce fibrillation during defibrillation threshold testing (DFT).
Receives: Diagnostic Test: Defibrillator threshold testing; Other: Observation of post-shock intrinsic cardiac rhythm

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Defibrillation Threshold

    The defibrillation threshold is a measure of the minimum amount of energy (in Joules) that is able to successfully defibrillate an episode of ventricular fibrillation. This measurement is specific to each individual patient with his/her specific defibrillator configuration. There are several different strategies to measuring this in an individual patient; this study utilized the binary search protocol.

    Measured: During clinical ICD procedure, as a single event

Secondary outcomes (2)
  1. Do DFTs Vary by Type of ICD Systems Implanted?

    The defibrillation threshold (as measured in Joules as already described in the details regarding the primary outcome) will be compared between patients with two distinct general types of implanted defibrillator systems: 1) transvenous ICD systems (defibrillator leads located inside the vein and attached to the endocardial surface of the heart) and 2) non-transvenous ICD systems (including all other types of debrillation systems).

    Measured: During clinical ICD procedure, as a single event

  2. Intrinsic Heart Rate in the Immediate Post-defibrillation Period

    A patient will be considered to have an intrinsic slow heart rate in the period of time immediately following defibrillation (20 seconds) if any of the following are observed: >7 paced beats, asystole >4 seconds, or experienced >10% decrease in systolic blood pressure.

    Measured: During clinical ICD procedure, as a single event

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Jan 2010 (estimated)
  2. Study start4 Jun 2009
  3. Primary completion26 May 2010
  4. Study completion10 May 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01043562
Sponsor's protocol ID
09-04-0209
Status last verified
Jul 2017
First submitted
6 Jan 2010
Last updated
5 Feb 2018
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Pediatrics and Defibrillators, Implantable, run by Boston Children's Hospital at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 5 Feb 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 5 Feb 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Defibrillation Threshold (time frame: During clinical ICD procedure, as a single event). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Feb 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.