Variable Ventilation During Acute Respiratory Failure

A study testing variable ventilation and Conventional ventilation in people with Acute Respiratory Failure, run by Boston Medical Center at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Acute respiratory failure requiring support with mechanical ventilation occurs with an incidence of 77-100 per 100,000 person-years and accounts for half of all patients admitted to the intensive care unit. Major causes of acute respiratory failure include pneumonia, asthma, emphysema, and acute lung injury. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Acute Respiratory Failure
What is being tested?
variable ventilation and Conventional ventilation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
7 participants
Where
1 siteUnited States
Study dates
Sep 2012to 23 Dec 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age > or equal to 18
  • Requires mechanical ventilation using a volume-controlled mode.
  • Admitted to Boston Medical Center Surgical, Medical, or Coronary Intensive Care Unit
  • Evidence of impaired oxygenation on mechanical ventilator defined by PaO2/FiO2 ratio less than 350 (corresponding to an A-a gradient of approximately 100) or SatO2/FiO2 ratio less than 358 (requiring O2 saturation less than or equal to 97%).
  • Meets "Clinical Stability Criteria" (on maximum of one vasopressor medication) for at least one hour prior to start of study protocol:
  • 5a. Hemodynamically stable: mean arterial pressure greater than 60 mmHg, heart rate greater than 50 and less than 130 bpm 5b. Respiratory system stable: Respiratory rate less than 35 bpm, O2 saturation greater than 88%, peak pressure on ventilator less than 40 cm H20, FiO2 not greater than 0.80, PEEP level not greater than 12.5 cm H2O, requires suctioning less than once hourly.
  • 5c. Acid-base stability: pH greater than 7.2 and less than 7.55 5d. Neurologic system stable: No agitation as defined by a Riker SAS Score between 2 (very sedated) and 4 (calm and cooperative) 6. Assent of primary ICU care team

Who cannot join

  • Do not resuscitate order
  • Increased intracranial pressure
  • Pregnancy (urine pregnancy test for all women of child-bearing age)
  • Planned transport out of ICU during planned study protocol
  • Coagulopathy (INR > 2.0 or PTT > 50)
  • Severe thrombocytopenia (platelets < 20,000)
Show all 10Show fewer
  • Patients receiving medications meant to increase oxygenation such as inhaled nitric oxide, inhaled prostacyclin, intravenous prostacyclin, and intravenous treprostinil
  • Any patient receiving a medication that is not consistent with FDA-approved labeling
  • A change in the Riker SAS during the study protocol that results in a Riker SAS score of 1: "Unarousable" (minimal or no response to noxious stimuli, does not communicate or follow commands) or 5: "Agitation" (anxious or physically agitated, calms to verbal instructions) for a duration of greater than 15 minutes
  • A Riker SAS of 6: "Very agitated" (requiring restraint and frequent verbal reminding of limits, biting ETT) or higher will result in immediate study discontinuation for the individual participant

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Boston Medical Center

    Boston, Massachusetts, 02118

Other trials in United States

About this study

Acute respiratory failure requiring support with mechanical ventilation occurs with an incidence of 77-100 per 100,000 person-years and accounts for half of all patients admitted to the intensive care unit. Major causes of acute respiratory failure include pneumonia, asthma, emphysema, and acute lung injury. These causes of acute respiratory failure may result in partial lung collapse (atelectasis), and airway narrowing (bronchoconstriction)that result in decreased oxygen levels requiring support with the ventilator. The prolonged inactivity in the supine position associated with mechanical ventilation can further result in atelectasis requiring increased oxygen supplementation through the ventilator.

The current standard of care in acute respiratory failure is a strategy of mechanical ventilation using a single lung volume delivered repeatedly. However, the current standard mechanical ventilation strategy is not consistent with the variability in respiration of healthy humans and has been shown to contribute to increased lung injury in some studies. The mortality associated with acute respiratory failure is high, 30-40%. Thus, improvements in mechanical ventilation strategies that improve oxygen levels and potentially decrease further lung injury delivered by the ventilator are warranted.

Read more

Recent studies by BU Professor Bela Suki and others in humans and animals with acute lung injury, bronchoconstriction, and atelectasis have shown that varying the lung volumes delivered by a ventilator significantly decreases biomarkers of lung injury, improves lung mechanics, and increases oxygenation when compared to identical mean volumes of conventional, monotonous low lung volume ventilation.

Therefore, we propose a first-in-human, Phase I study to evaluate the safety of this novel mode of ventilation, Variable Ventilation, during acute respiratory failure

Being tested
variable ventilation, Conventional ventilation
Keywords
oxygenation, ventilation, tidal volume, patterns of breathing, variable ventilation, mechanical ventilation
Medical subject headings
Respiratory Aspiration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • variable ventilationDevice

    In variable ventilation, the tidal volume on the Puritan-Bennett 840 ventilator will be randomly varied by 40% on a breath-by-breath basis around a pre-set mean, using the variable ventilation software developed by Dr. Bela Suki and Dr. Arnab Majumdar. In conventional ventilation, the tidal volume on the Puritan-Bennett 840 ventilator will be set to equal the mean tidal volume used in variable ventilation and does not vary.

  • Conventional ventilationOther

    tidal volume will be set as the patient's baseline tidal volume prior to study entry and will not vary.

Study groups in NCT01083277
Study groupRoleWhat they receive
variable ventilationExperimentalA novel means of conducting mechanical ventilation that involves an approximately 40% variation in tidal volume around a set mean tidal volume
Receives: Device: variable ventilation
conventional ventilationOtherThis is the control arm of the study, in which tidal volume will be set as the patient's baseline tidal volume prior to study entry and will not vary.
Receives: Other: Conventional ventilation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The occurrence of adverse events in the use of variable ventilation versus conventional ventilation, including the loss of any of the following (1) hemodynamic stability, (2) respiratory stability,(3) acid-base stability, and (4) neurological stability.

    Measured: Up to 24 hours after the end of the study period

Secondary outcomes (1)
  1. Oxygenation

    PaO2

    Measured: 3 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Mar 2010 (estimated)
  2. Study startSep 2012
  3. Primary completionJul 2016
  4. Study completion23 Dec 2016

Why it stopped: Slow enrollment

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
7 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01083277
Sponsor's protocol ID
H-27864
Status last verified
Jul 2017
First submitted
18 Sep 2009
Last updated
11 Jul 2017
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing variable ventilation and Conventional ventilation in people with Acute Respiratory Failure, run by Boston Medical Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 11 Jul 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Slow enrollment). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The occurrence of adverse events in the use of variable ventilation versus conventional ventilation, including the loss of any of the following (1) hemodynamic stability, (2) respiratory stability,(3) acid-base stability, and (4) neurological stability. (time frame: Up to 24 hours after the end of the study period). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Jul 2017.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in