Electrical Impedance Tomography (EIT)is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax. It is a radiation free, non-invasive and portable lung imaging technique. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Electrical Impedance Tomography (EIT)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteGermany
Study dates
Jan 2011to Apr 2011
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Female and male patients > 18 years old
  • Mechanically ventilated patients who routinely undergo bronchoscopy

Who cannot join

  • Pregnancy and Breastfeeding
  • Active implants, heart pace makers and implanted converter defibrillator
  • Foreign metallic objects in the thorax
  • Cardiac valves

Trial locations and contacts

1 site in 1 country.

Germany1 site, 1 recruiting
  • Faculty Medical Clinic 1, University Hospital Aachen

    Aachen, North Rhine-Westphalia, 52074

    Stefan Krueger, MD, Assistant Professor, ++49 241 80 80202 ext. 80202, stkrueger@ukaachen.de

    Sigrid Gloeggler, M.Sc., ++49 241 8035226 ext. 35226, sgloeggler@ukaachen.de

    Recruiting

Other trials in Germany

About this study

Official title: Bronchoscopy and Electric Impedance Tomography to Investigate the Influence of Bronchoscopy on Pulmonary Regional Ventilation Measurements by Electric Impedance Tomography (EIT)

Electrical Impedance Tomography (EIT)is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax. It is a radiation free, non-invasive and portable lung imaging technique. Impedance changes in lung ventilation are investigated in mechanically ventilated patients who routinely undergo bronchoscopy in intensive care medicine. Bronchoscopy is performed to suction secretions as well as to analyze the secretions to recognize inflammations and diseases. It is an essential intervention which causes changes in ventilation which remain for 1-2 hours. It is not completely investigated why these changes in ventilation remain for so long time and how they are distributed regionally. Therefore the purpose of this study is to investigate the change in pulmonary regional ventilation in patients who routinely undergo bronchoscopy to possibly generate ideas how to optimize the ventilation after bronchoscopy to optimize the patient´s treatment.

Read the detailed description

In 20 mechanically ventilated patients who routinely undergo bronchoscopy Electrical Impedance Tomography (EIT) measurements whereby, evaluable data of 10 patients are needed, of about 1-2 minutes are performed directly before, directly after and 10, 30, and 60 minutes after bronchoscopy parallel to the following routine measurements: tidal volume, resistance, compliance, heart rate, blood pressure, SpO2 and blood gas values. Prior to the examination a rubber belt with 16 integrated electrocardiographic electrodes is placed around the thorax connected with an EIT- device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. The EIT provides a mapping of the distribution of the lung´s electrical impedance and exhibits a far temporal resolution of up to 40 tomograms per second. Because of electrical impedance of the pulmonal tissue is dependant to the air content, the air distribution within the lung over a certain period can be monitored. Analyzing the EIT- data it might be possible to explain the distribution in regional ventilation and how the ventilation could be optimized right after the bronchoscopy to optimize the patient´s treatment.

Being tested
Electrical Impedance Tomography (EIT)
Keywords
Electric Impedance Tomography (EIT), Ventilation, Bronchoscopy, Lung Impedance, Recruitment
Medical subject headings
Respiratory Aspiration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electrical Impedance Tomography (EIT)Device

    EIT measurements of 1-2 minutes are performed in patients who routinely undergo bronchoscopy (during 1.5 hours) before, directly after and 10, 30, 60 minutes after bronchoscopy. Therefore the rubber belt including 16 integrated electrographic electrodes is placed around the patient´s chest and connected with an EIT device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. Pseudonomyzed EIT data are evaluated descriptively.

Study groups in NCT01294813
Study groupRoleWhat they receive
Bronchoscopy-EITExperimentalPatients who routinely undergo bronchoscopy will be measured by EIT directly before, directly after and 10, 30, 60 minutes after bronchoscopy with a rubber belt which is placed around their chest. The EIT measurements will take 1-2 minutes; the total examination will last 1.5 hours.
Receives: Device: Electrical Impedance Tomography (EIT)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison of the change in lung impedance due to ventilation before and after bronchoscopy by EIT measurements

    It will be investigated if there are changes in lung impedance due to changes in ventilation before, directly after and 10, 30, 60 minutes after bronchoscopy in order to investigate their regional distribution and to generate ideas how the ventilation could be optimized to improve recruitment of the patient´s treatment

    Measured: Single Measurement of 1.5 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Feb 2011 (estimated)
  2. Study startJan 2011
  3. Primary completionApr 2011 (estimated)
  4. Study completionApr 2011 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Basic science
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01294813
Sponsor's protocol ID
Bronchoscopy- EIT
Acronym
Broncho-EIT
Status last verified
Feb 2011
First submitted
10 Feb 2011
Last updated
16 Feb 2011
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Electrical Impedance Tomography (EIT) in people with Electric Impedance Tomography and Bronchoscopy, run by RWTH Aachen University at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 16 Feb 2011. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Stefan Krueger, MD (0049 241 8080202 ext. 80202, stkrueger@ukaachen.de), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison of the change in lung impedance due to ventilation before and after bronchoscopy by EIT measurements (time frame: Single Measurement of 1.5 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Feb 2011.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in