Arterial DiseaseSENS-FPNCT01570803
Efficacy Between Different Two Self-Expanding Nitinol Stents For The Atherosclerotic Femoro-Popliteal Arterial Disease
A study testing Complete SE Stent in people with Arterial Disease and Atherosclerosis, run by Korea University Guro Hospital at 2 sites in South Korea.
Trial summary
Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment. Although there have been several retrospective or registry studies for atherosclerotic femoropopliteal disease in the East, there have been few randomized control trial… Read more about this study
- Who is it for?
- Ages 20 to 90 years
- Conditions the study is for
- Arterial Disease, Atherosclerosis
- What is being tested?
- Complete SE Stent
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 0 participants
- Where
- 2 sitesSouth Korea
- Study dates
- Jan 2013to Jan 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 90 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Clinical criteria
- Age 20 years of older
- Symptomatic peripheral-artery disease with (Rutherford 2 - 6); moderate to severe claudication (Rutherford 2-3), chronic critical limb ischemia with pain while was at rest (Rutherford 4), or with ischemic ulcers (Rutherford 5-6)
- Patients with signed informed consent
- Anatomical criteria
- Stenosis of >50% or occlusive atherosclerotic lesion of the ipsilateral femoropopliteal artery
- Patent (≤50% stenosis) ipsilateral iliac artery or concomitantly treatable ipsilateral iliac lesions (≤30% residual stenosis),
- At least one patent (less than 50% stenosed) tibioperoneal run-off vessel.
Who cannot join
- Disagree with written informed consent
- Major bleeding history within prior 2 months
- Known hypersensitivity or contraindication to any of the following medication: heparin, aspirin, clopidogrel, cilostazol, or contrast agent
- Acute limb ischemia
- Previous bypass surgery or stenting of the ipsilateral femoropopliteal artery
- Untreated inflow disease of the ipsilateral pelvic arteries (more than 50% stenosis or occlusion)
- Patients that major amputation ("above the ankle" amputation) has been done, is planned or required
- Patients with life expectancy <1 year due to comorbidity
Trial locations and contacts
2 sites in 1 country.
South Korea2 sites
Cardiovascular center, Korea University Guro Hospital
Seoul, 152-703
Korea University Guro Hospital
Seoul, 152-703
About this study
Official title: Efficacy of Self-Expanding Nitinol S.M.A.R.T-CONTROL Stent Versus Complete SE Stent For The Atherosclerotic Femoro-Popliteal Arterial Disease : Prospective, Multicenter, Randomized, Controlled Trial (SENS-FP Trial)
Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment. Although there have been several retrospective or registry studies for atherosclerotic femoropopliteal disease in the East, there have been few randomized control trial for comparison of stent fracture and primary patency between different nitinol stents. Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent. On the other hand, 2011 ESC guideline recommended that dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infrainguinal bare-metal-stent implantation. Recent meta-analysis has shown that the efficacy of cilostazol in the atherosclerotic femoropopliteal lesion was proven. However, still specific data regarding a variety of antiplatelet regimen are limited. To date, there is no the study for comparison between clopidogrel and cilostazole in patient undergone stent implantation in femoropopliteal lesion. In conclusion, the purpose of our study is to examine and compare Primary patency and stent fracture between different two-nitinol stents (S.M.A.R.T. CONTROL versus Complete SE) and to compare binary restenosis rate between clopidogrel and cilostazol in femoropopliteal arterial lesion.
Read the detailed description
Five randomized, controlled trials failed to demonstrate any benefit of a stainless-steel stent over angioplasty alone. The nitinol stent has proven superior primary patency than balloon angioplasty in superficial femoral artery (SFA) lesions. Several studies reported stent fractures were associated with a higher risk of in-stent restenosis and reocclusion. In vitro, Stefan et al. reported the 7 different SFA stents showed differences in the incidence of high strain zones, which indicates a potential for stent fracture, as demonstrated by the mechanical fatigue tests. They claimed differences in stent design might play a major role in the appearance of stent strut fracture related to restenosis and reocclusion. Also, in retrospective study, Iida et al. reported there was significant difference in stent fracture between S.M.A.R.T. stent group and Luminexx stent group and primary patency was worse in those associated with stent fracture than in those without stent fractures. Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment.
The design of self-expandible nitinol stents might be different depending on the developed time; The first-generation nitinol stents (e.g., LuminexxTM and SmartTM) showed a remarkably high rate of stent strut fracture. A second generation of slotted tube nitinol stents has been developed. These stents had a better flexibility, by reducing the number of connections between cells or crowns, and by configurating spiral orientation of these interconnections. Several studies reported that these nitinol stents are more fracture-resistant and more flexible, some of them providing superior patency rate (e.g., LifeTM and EverflexTM). However, the one of the important limitations to their studies is that those was the non-randomized study of relative small sample size or was confined to in-vitro. Upto date, the multicenter, randomized controlled trial for direct comparison of stent fracture and primary patency between two different nitinol stents has not been done except one study; SMART versus Luminexx stent. SMART and Luminexx stent have been classified into 1st generation self-expandable nitinol stent. Complete-SE stent of Medtronic company was different to Smart stent of Cordis company in that the configuration of interconnection of Complete-SE stent had peak-to-peak connection and more spiral orientation of interconnection, compared to mart stent. On the other hand, Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent.
On the other hand, to date, in previous many reports, the dual antiplatelet therapy consisted of aspirin and clopidogrel have proven to decrease the incidence of cardiovascular death, myocardial infarction, or revascularization without an increase in major bleeding in patients who underwent percutaneous coronary intervention regardless of stent type (bare metal stent or drug-eluting stent). In 2011 ESC (European society of cardiology) guideline, dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infra-inguinal bare metal stent implantation (Class I, Level C). However, there have been no the definite evidence or guideline for the optimal antiplatelet agents after stent implantation one month later. There have been many studies for the efficacy of thienopyridine in peripheral arterial disease. Also, With the potential benefit of cilostazol on vascular function in vitro, there have several previous efforts to prove the efficacy of cilostazol in patients undergoing endovascular therapy or stent implantation in peripheral arterial disease. However, still specific data regarding a variety of antiplatelet regimen are limited. Also, very few trials have effectively nor properly addressed the direct comparison for the efficacy and safety between clopidogrel and cilostazol. This trial designed to evaluate the efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions.
- Conditions
- Arterial Disease, Atherosclerosis
- Being tested
- S.M.A.R.T CONTROL Stent, Complete SE Stent
- Keywords
- peripheral arterial disease,, atherosclerosis,, nitinol,, stents
- Medical subject headings
- Atherosclerosis, Peripheral Arterial Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
S.M.A.R.T CONTROL StentDevice
Provisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled. The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation. Recommended, minimal balloon dilation time is 120 seconds. The sub-optimal balloon response is defined as a residual pressure gradient of >15 mmHg, residual stenosis of >30%, and flow-limiting dissection.
Complete SE StentDevice
same to SMART CONTROL Stent
| Study group | Role | What they receive |
|---|---|---|
| Complete SE Stent | Experimental | study design is 2x2 randomization design. First, before randomization, stratification will be performed according to lesion length 15cm criteria at web-based computerized program. Patients will be randomized in a 1:1 manner according to different two (SMART versus Complete-SE) stents. And then, patients received aspirin and clopidogrel during one month. After one month from index procedure, patients were randomized to receive either clopidogrel group (clopidogrel will not be changed but continue) or cilostazol group (clopidogrel will be changed into cilostazol) in separate groups of SMART group and Complete SE group. Randomization procedure will be performed using a web-based program Receives: Device: Complete SE Stent |
| SMART CONTROL Stent | Active comparator | same to Complete SE Receives: Device: S.M.A.R.T CONTROL Stent |
What is being measured
The primary outcome is the main question the study is designed to answer.
The rate of binary restenosis
the rate of binary restenosis (stenosis of at least 50 percent of the luminal diameter) or PSVR ≥ 2.5 or zero (PSVR=peak systolic velocity within the area of stenosis divided by peak systolic velocity in a normal adjacent proximal artery segment) in the treated segment at 12 months after intervention as determined by catheter angiography or Duplex ultrasound
Measured: one year
Secondary outcomes (1)
stent fracture rate, clinical outcomes, angiographic outcomes, ankle-brachial index
- stent fracture rate according to fracture grade (minor, moderate, severe
- Limb salvage rate free of above-the-ankle amputation
- Sustained clinical improvement rate at 12 month follow-up
- Repeated target lesion revascularization (TLR) rate
- Repeated target extremity revascularization (TER) rate
- Total re-occlusion rate
- Comparison of angiographic variables consisted of late loss and % restenosis
- Ankle-brachial index (ABI) at 12 months
- The rate of major adverse cardiovascular events (MACE) composed of all-cause death, myocardial infarction, and stroke at 12 months
- Incidence of geographic miss during stent deployment due to jumping and elongation
- The rate of binary restenosis or PSVR ≥ 2.5 or zero according to clopidogrel and cilostazol
- Major bleeding rate between clopidogrel and cilostazol group.
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Apr 2012 (estimated)
- Study startJan 2013 (estimated)
- Primary completionJan 2018 (estimated)
- Study completionJan 2018 (estimated)
Why it stopped: Study could not be initiated due to lack of research funding from the sponsors.
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Arterial DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 0 participants (actual)
Sponsor and investigators
- Lead sponsor
- Korea University Guro Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Seung Woon Rha, Korea University Guro Hospital
- Investigators
- Seung-Woon Rha, MD, PhD, Principal investigator, Cardiovascular Center, Korea University Guro Hospital, 80, Guro-dong, Guro-gu, Seoul, 152-703, Korea
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01570803
- Sponsor's protocol ID
- SENS-FP
- Acronym
- SENS-FP
- Status last verified
- Mar 2018
- First submitted
- 2 Apr 2012
- Last updated
- 15 Mar 2018
- Results posted
- No
- Data monitoring committee
- Yes
- Individual data sharing
- No
Publications
Park SH, Rha SW, Choi CU, Kim EJ, Oh DJ, Cho YH, Choi WG, Lee SJ, Kim YH, Choi SH, Kim WH, Kim KC, Cho JH, Kim JH, Kim SM, Bae JH, Bong JM, Kang WY, Baek JY, Seo JB, Chung WY, Park MW, Her SH, Suh J, Kim MW, Kim YJ, Choi HJ, Soh JW; SENS-FP Investigators. Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial. Trials. 2014 Sep 10;15:355. doi: 10.1186/1745-6215-15-355.
PubMed 25208688
Study at a glance
From the registry record, last updated by the sponsor on 15 Mar 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Efficacy of Self-Expanding Nitinol S.M.A.R.T-CONTROL Stent Versus Complete SE Stent For The Atherosclerotic Femoro-Popliteal Arterial Disease : Prospective, Multicenter, Randomized, Controlled Trial (SENS-FP Trial)
- ClinicalTrials.gov ID
- NCT01570803
- Acronym / sponsor ID
- SENS-FP / SENS-FP
- Conditions
- Arterial Disease, Atherosclerosis
- Keywords
- peripheral arterial disease,, atherosclerosis,, nitinol,, stents
- Study type
- Interventional
- Recruitment status
- WithdrawnReason stopped: Study could not be initiated due to lack of research funding from the sponsors.
- Enrolment
- 0 participants (actual)
- Lead sponsor
- Korea University Guro HospitalUniversity, hospital or other
- Study start
- Jan 2013 (estimated)
- Primary completion
- Jan 2018 (estimated)
- Study completion
- Jan 2018 (estimated)
- First posted
- 4 Apr 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment. Although there have been several retrospective or registry studies for atherosclerotic femoropopliteal disease in the East, there have been few randomized control trial for comparison of stent fracture and primary patency between different nitinol stents. Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent. On the other hand, 2011 ESC guideline recommended that dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infrainguinal bare-metal-stent implantation. Recent meta-analysis has shown that the efficacy of cilostazol in the atherosclerotic femoropopliteal lesion was proven. However, still specific data regarding a variety of antiplatelet regimen are limited. To date, there is no the study for comparison between clopidogrel and cilostazole in patient undergone stent implantation in femoropopliteal lesion. In conclusion, the purpose of our study is to examine and compare Primary patency and stent fracture between different two-nitinol stents (S.M.A.R.T. CONTROL versus Complete SE) and to compare binary restenosis rate between clopidogrel and cilostazol in femoropopliteal arterial lesion.
Detailed description
Five randomized, controlled trials failed to demonstrate any benefit of a stainless-steel stent over angioplasty alone. The nitinol stent has proven superior primary patency than balloon angioplasty in superficial femoral artery (SFA) lesions. Several studies reported stent fractures were associated with a higher risk of in-stent restenosis and reocclusion. In vitro, Stefan et al. reported the 7 different SFA stents showed differences in the incidence of high strain zones, which indicates a potential for stent fracture, as demonstrated by the mechanical fatigue tests. They claimed differences in stent design might play a major role in the appearance of stent strut fracture related to restenosis and reocclusion. Also, in retrospective study, Iida et al. reported there was significant difference in stent fracture between S.M.A.R.T. stent group and Luminexx stent group and primary patency was worse in those associated with stent fracture than in those without stent fractures. Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment.
The design of self-expandible nitinol stents might be different depending on the developed time; The first-generation nitinol stents (e.g., LuminexxTM and SmartTM) showed a remarkably high rate of stent strut fracture. A second generation of slotted tube nitinol stents has been developed. These stents had a better flexibility, by reducing the number of connections between cells or crowns, and by configurating spiral orientation of these interconnections. Several studies reported that these nitinol stents are more fracture-resistant and more flexible, some of them providing superior patency rate (e.g., LifeTM and EverflexTM). However, the one of the important limitations to their studies is that those was the non-randomized study of relative small sample size or was confined to in-vitro. Upto date, the multicenter, randomized controlled trial for direct comparison of stent fracture and primary patency between two different nitinol stents has not been done except one study; SMART versus Luminexx stent. SMART and Luminexx stent have been classified into 1st generation self-expandable nitinol stent. Complete-SE stent of Medtronic company was different to Smart stent of Cordis company in that the configuration of interconnection of Complete-SE stent had peak-to-peak connection and more spiral orientation of interconnection, compared to mart stent. On the other hand, Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent.
On the other hand, to date, in previous many reports, the dual antiplatelet therapy consisted of aspirin and clopidogrel have proven to decrease the incidence of cardiovascular death, myocardial infarction, or revascularization without an increase in major bleeding in patients who underwent percutaneous coronary intervention regardless of stent type (bare metal stent or drug-eluting stent). In 2011 ESC (European society of cardiology) guideline, dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infra-inguinal bare metal stent implantation (Class I, Level C). However, there have been no the definite evidence or guideline for the optimal antiplatelet agents after stent implantation one month later. There have been many studies for the efficacy of thienopyridine in peripheral arterial disease. Also, With the potential benefit of cilostazol on vascular function in vitro, there have several previous efforts to prove the efficacy of cilostazol in patients undergoing endovascular therapy or stent implantation in peripheral arterial disease. However, still specific data regarding a variety of antiplatelet regimen are limited. Also, very few trials have effectively nor properly addressed the direct comparison for the efficacy and safety between clopidogrel and cilostazol. This trial designed to evaluate the efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Complete SE Stent | Experimental | Device: Complete SE Stentstudy design is 2x2 randomization design. First, before randomization, stratification will be performed according to lesion length 15cm criteria at web-based computerized program. Patients will be randomized in a 1:1 manner according to different two (SMART versus Complete-SE) stents. And then, patients received aspirin and clopidogrel during one month. After one month from index procedure, patients were randomized to receive either clopidogrel group (clopidogrel will not be changed but continue) or cilostazol group (clopidogrel will be changed into cilostazol) in separate groups of SMART group and Complete SE group. Randomization procedure will be performed using a web-based program |
| SMART CONTROL Stent | Active comparator | Device: S.M.A.R.T CONTROL Stentsame to Complete SE |
Who may qualify
- Ages
- 20 to 90 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (8 listed)
- Clinical criteria
- Anatomical criteria
Key exclusion criteria (8 listed)
- Disagree with written informed consent
- Major bleeding history within prior 2 months
- Known hypersensitivity or contraindication to any of the following medication: heparin, aspirin, clopidogrel, cilostazol, or contrast agent
- Acute limb ischemia
- Previous bypass surgery or stenting of the ipsilateral femoropopliteal artery
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| S.M.A.R.T CONTROL StentProvisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled. The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation. Recommended, minimal balloon dilation time is 120 seconds. The sub-optimal balloon response is defined as a residual pressure gradient of >15 mmHg, residual stenosis of >30%, and flow-limiting dissection. | Device | SMART CONTROL Stent |
| Complete SE Stentsame to SMART CONTROL Stent | Device | Complete SE Stent |
Primary outcome
The rate of binary restenosis
Time frame: one year
the rate of binary restenosis (stenosis of at least 50 percent of the luminal diameter) or PSVR ≥ 2.5 or zero (PSVR=peak systolic velocity within the area of stenosis divided by peak systolic velocity in a normal adjacent proximal artery segment) in the treated segment at 12 months after intervention as determined by catheter angiography or Duplex ultrasound
1 secondary outcome
stent fracture rate, clinical outcomes, angiographic outcomes, ankle-brachial index
Time frame: 1 year
Results and safety
The study was withdrawn before enrolling participants, so there are no results.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Mar 2018.
- Derived from this study: PubMed 25208688Park SH, Rha SW, Choi CU, Kim EJ, Oh DJ, Cho YH, Choi WG, Lee SJ, Kim YH, Choi SH, Kim WH, Kim KC, Cho JH, Kim JH, Kim SM, Bae JH, Bong JM, Kang WY, Baek JY, Seo JB, Chung WY, Park MW, Her SH, Suh J, Kim MW, Kim YJ, Choi HJ, Soh JW; SENS-FP Investigators. Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial. Trials. 2014 Sep 10;15:355. doi: 10.1186/1745-6215-15-355.
- Individual participant dataSharing planned: No
Related trials for Arterial Disease
Recruiting
Effects of Pitavastatin or Combination of Pitavastatin and Ezetimibe on Glucose Metabolism Compared to AtoRvastatin in atheroscLerotic Cardiovascular Disease Patients With Metabolic Syndrome: The EZ-PEARL Randomized Trial
Dyslipidemias, Atherosclerotic Cardiovascular Disease
Recruiting
Pivotal Study of the SUpira System in Patients Undergoing High-Risk Percutaneous COronaRy InTervention (HRPCI)
Coronary Artery Disease, High Risk Percutaneous Coronary Intervention
Active, not recruitingObservational study
Post-Induction Low Cardiac Output Syndrome in Coronary Artery Bypass Graft Surgery
Cardiac Output, Low, Coronary Arterial Disease
RecruitingPhase 3
A Clinical Trial To Investigate The Effect Of EA-230 On Hospital Length Of Stay In Patients With Coronary Artery Disease (CAD) Undergoing Coronary Artery Bypass Grafting (CABG) Surgery.
Coronary Artery Disease (CAD), Coronary Artery Bypass Graft Surgery(CABG)
Recruiting
Pharmacogenomic Informed Statin Prescribing
Hypercholesterolemia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Seung-Woon Rha, MD, PhD principal investigator
Cardiovascular Center, Korea University Guro Hospital, 80, Guro-dong, Guro-gu, Seoul, 152-703, Korea
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Complete SE Stent in people with Arterial Disease and Atherosclerosis, run by Korea University Guro Hospital at 2 sites in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: withdrawn, as of the sponsor's last update on 15 Mar 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was withdrawn before enrolling participants, so there are no results.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The rate of binary restenosis (time frame: one year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01570803, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Mar 2018.