Acute Coronary SyndromesPhase 3NCT01669382
Angio-Seal® vs. Exo-Seal® for Closure of Arterial Puncture Sites
A Phase 3 study testing percutaneous coronary intervention in people with Acute Coronary Syndromes and Stable Angina Pectoris, run by University Hospital Erlangen at 3 sites in Germany.
Trial summary
Background: Vascular closure devices (VCD) were developed to reduce access site bleedings, to improve patients´ comfort, and to accelerate ambulation after percutaneous coronary interventions (PCI). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Acute Coronary Syndromes, Stable Angina Pectoris
- What is being tested?
- percutaneous coronary intervention
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 304 participants
- Where
- 3 sitesGermany
- Study dates
- Jan 2012to Sep 2012
- Phase
- Phase 3
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- all patients who receive coronary angiography/intervention with an 6 F sheath
Who cannot join
- severe calcification of the access vessel,
- severe peripheral artery disease,
- puncture in the origin of the profound femoral artery,
- non-femoral sheath insertion,
- marked tortuosity of the femoral or iliac artery,
- marked obesity or cachexia (BMI >40 or <20)
- patients on continuous medication with oral anticoagulants.
Trial locations and contacts
3 sites in 1 country.
Germany3 sites
Klinikum Coburg
Coburg, 96450
Universitätsklinikum Erlangen; Medizinische Klinik 2
Erlangen, 91054
Universitätsklinikum Gießen, Klinik für Kardiologie
Giessen, 35392
About this study
Official title: ACCESS: A Randomized, Multicenter, Single-Blinded Trial to Compare the Extrafemoral Closure Device Exo-Seal® and the Collagen-based Intravascular Device Angio-SealTM for Arterial Puncture Site Closure.
Background:
Vascular closure devices (VCD) were developed to reduce access site bleedings, to improve patients´ comfort, and to accelerate ambulation after percutaneous coronary interventions (PCI). Despite higher complications rates in earlier studies, current data suggest similar complication rates or better outcomes after the use of VCD as compared to manual compression. ExoSeal (Cordis, Warren, NJ, USA) is a new, extravascular polyglycol acid (PGA) plug which occludes the puncture channel. Whether the use of this extravascular closure device is as effective as the more widely used plug/anchor mediated devices, has not been evaluated so far.
Read more
We performed a randomized, multicentre, single-blinded trial to compare the efficacy of the extravascular closure device ExoSeal in comparison to the collagen-based plug/anchor mediated AngioSeal system.
Methods:
304 patients receiving diagnostic angiography and/or PCI will be included in three centers. Exclusion criteria are contraindications for any VCD including 1. severe calcification of the access vessel, 2. severe peripheral artery disease, 3. puncture in the origin of the profound femoral artery, 3. non-femoral sheath insertion, 4. marked tortuosity of the femoral or iliac artery, 5. marked obesity or cachexia (BMI >40 or <20) and 6. patients on continuous medication with oral anticoagulants.
After the procedure, angiography of the accessed femoral artery is performed to rule out major risk factors for retroperitoneal hemorrhage, relevant peripheral stenoses of the common or the superficial femoral artery, or a location of the puncture site in the bifurcation of the profundal femoral artery.
We hypothesise, that the use of an extravascular closure device is not inferior to an anchor/plug mediated device regarding the occurrence of the following complications: bleeding, need for vascular surgery and device failure (primary endpoints). Secondary endpoints are the occurrence of false aneurysms, severe pain (Borg ≥ 5), and hematoma ≥ 5 cm within 24 hours after insertion of the device. Power was 80%, alpha 0.05. Bleeding will be defined according to the TIMI criteria. The study is actively enrolling patients, last inclusion will take place in September 2012.
Results and Conclusions:
Outcome data including the primary endpoint (bleeding, need for vascular surgery and device failure) will be presented for the first time.
Read the detailed description
Introduction In patients undergoing percutaneous coronary interventions (PCI) there is a rate of vascular complications of 0.8% to 5.5% (1). Albeit femoral sheaths sizes were reduced, arterial compression and long-term dressing after PCI still bear tremendous discomfort and groin pain for the patients. Furthermore, manual compression of the puncture site should be performed until activated clotting time is below 180 seconds (2).
Therefore, vascular closure devices (VCD) were developed to reduce access site bleedings, to improve patients´ comfort, and to accelerate ambulation after PCI.
The hemostatic puncture closure device Angio-Seal (St. Jude Medical, St. Paul, MS, USA) is a collagen based plug system with an anchor in the inner vessel wall. ExoSeal (Cordis, Warren, NJ, USA) is a extravascular polyglycol acid (PGA) plug, which closes the puncture site on an extravascular basis while occluding the puncture channel.
The aim of the current, randomized study is, to evaluate the effectiveness, safety and reliability of 2 different vascular closure devices.
Methods Consecutive patients with stable angina pectoris or silent ischemia with a positive stress test will be randomized to either Angio-Seal or Exo-Seal, and included into the study after giving written informed consent.
Patients with contraindications for any VCD including 1. severe calcifications of the vessel site, 2. severe peripheral artery disease, 3. puncture in the origin of the femoral profundal artery, 3. non-femoral sheath insertion, 4. marked tortuosity of the femoral or iliac artery, and 5. marked obesity (BMI >40) or 6. cachexia (BMI <20) will be excluded from the study (3). As clinical exclusion criteria will serve: 1. any emergency intervention, 2. the use of Glycoprotein IIb/IIIa-antagonists during the intervention, and 3. patients on continuous medication with oral anticoagulants.
All patients will be loaded with either 300 mg or 600 mg of Clopidogrel or 60 mg of Prasugrel or 180 mg of Ticagrelor, followed by a maintenance dose of 75 mg or 150 mg of Clopidogrel or 5 mg or 10 mg of Prasugrel, or 90 mg of Ticagrelor prior to the intervention. After insertion of a 6 F sheath, unfractionated Heparin (UF) will be given until an activated clotting time-level (ACT) of 250 s will be achieved. The use of low -molecular weight Heparin (LMWH) according to the recommendations of the manufacturers for the purpose of anticoagulation during PCI is possible. The simultaneous use of UF and LMWH should be avoided.
Patients should receive PCI according to standard protocols (8). After the procedure, an angiography of the accessed femoral artery should be performed to rule out major risk factors for retroperitoneal hemorrhage, relevant peripheral stenoses of the common or the superficial femoral artery, or a location of the puncture site in the bifurcation of the profundal femoral artery (9). In addition, this method will identify patients with a non-femoral artery sheath insertion, for which the VCD utilization is not proven (10). Patients with strong tortuosity and/or calcification of the femoral arteries should also be excluded from the study (see exclusion criteria).
Towards the end of the intervention the ACT should be recorded again: Angio-Seal or ExoSeal may be implanted when ACT is < 300s. In patients randomized to manual compression with or without patch the sheath should be removed when the ACT is < 180s.
The use of protamine is left to the discretion of the operator. In patients randomized to either Angio-Seal or Exo-Seal the placement should be performed using the manufacturer´s recommended technique. The operator should be familiar with any device used in the study, and should have performed vascular closure with those devices at least fifty times.
After insertion of the VCD a circular groin dressing will be applied, and patients will be immobilized for 4 hours. After this, the arterial puncture site will be examined, and auscultation will be performed. If there is no relevant complication, ambulation will be initiated.
Pain during closure procedure or manual compression will be categorized according to the Borg scale, with minor pain defined as Borg < 5 and major pain as Borg ≥ 5 (13).
In patients with manual compression with or without patch, immobilization will last 8 hours. After this, inspection of the puncture site will be performed as mentioned above.
Anticoagulation either with unfractionated heparin or low molecular weight heparin will be restarted 6 hours after resolution of the dressing. On the subsequent day, ultrasound and Doppler spectral analysis of the puncture site will be performed in all patients.
Complications will be assessed as being major or minor: Major complications are defined as need for vascular surgery, false aneurysm, AV-fistula, strong pain (Borg ≥ 5), hematoma ≥ 5 cm and major bleeding, whereas minor pain, hematoma < 5 cm and new wound dressing will be classified as minor complications. Bleeding will be identified as bleeding according to the TIMI criteria (12). TIMI major bleeding is defined as hemoglobin drop > 5 g/dl (with or without an identified site), TIMI "loss no site" as a haemoglobin drop > 4 g/dl but < 5 g/dl without an identified bleeding site, and TIMI minor bleeding as a hemoglobin drop > 3 g/dl but < 5 g/dl with bleeding from a known site or spontaneous gross hematuria.
Again pain will be categorized according to the Borg scale, with minor pain defined as Borg < 5 and major pain as Borg ≥ 5 (13).
Demographic and procedural data will be prospectively collected using a standardized procedural data sheet. This includes date and type of intervention, sheath size, procedure-related drug doses, and number of previous interventions. Major or minor complications, as well as the time of events will be recorded.
Statistical analysis Randomization will be performed Statistical analyses will be performed with SPSS version 16.0 (SPSS Inc., Chicago, IL, USA). Continuous data are expressed as mean values +/- standard deviation. For comparisons between paired data the students t-test will be used. A p-value < 0.05 will be regarded as statistically significant.
Risk-benefit ratio Achieving adequate hemostasis is crucial for the prevention of access site complications in patients undergoing PCI (3). The occurrence of vascular complications was an independent predictor of nonfatal myocardial infarction or death within one year after intervention (14), and has been associated with a significant increase in mortality (15). Advanced age, female gender, pre-existing vascular disease, emergent procedures, low body surface area (4, 8, 14), diabetes, hypertension, and cigarette smoking (15, 16) are also associated with an increased bleeding risk. Therefore adequate hemostasis still remains a challenge in interventional cardiology.
The recently introduced extravascular closure device ExoSeal theoretically offer some advantages. First, there is no foreign body, which is introduced into the artery, which, once misplaced potentially can lead to an occlusion of the artery, or to inflammation or allergic reactions. In addition to that , those devices might be used in patients with common contraindications for VCD´s like calcification, peripheral artery disease and tortuosity of the artery.
Since these devices are already introduced, but not evaluated sufficiently, there is need for a randomized comparison with an established system.
The risk-benefit ratio is well on the site of benefit, since all devices are regularly used in interventional cardiology and the estimated complication rate is in the range or even lower, than those, reported in the literature.
- Conditions
- Acute Coronary Syndromes, Stable Angina Pectoris
- Being tested
- percutaneous coronary intervention
- Keywords
- AngioSeal, ExoSeal, PCI, puncture site
- Medical subject headings
- Acute Coronary Syndrome, Angina, Stable
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
percutaneous coronary interventionDevice
Also called Exo Seal for closure of arterial puncture site
after the intervention patients are randomized to either Angio Seal or Exo Seal
| Study group | Role | What they receive |
|---|---|---|
| Exo Seal system | Active comparator | Percutaneous coronary intervention Receives: Device: percutaneous coronary intervention |
| AngioSeal system | Active comparator | percutaneous coronary intervention Receives: Device: percutaneous coronary intervention |
What is being measured
The primary outcome is the main question the study is designed to answer.
bleeding, need for vascular surgery and device failure
bleeding, need for vascular surgery and device failure will be measured as primary endpoints within the first 24 hours.
Measured: 24 hours
Secondary outcomes (1)
occurrence of false aneurysms, severe pain (Borg ≥ 5), and hematoma ≥ 5 cm within 24 hours after insertion of the device.
Secondary endpoints are the occurrence of false aneurysms, severe pain (Borg ≥ 5), and hematoma ≥ 5 cm within 24 hours after insertion of the device.
Measured: 24 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Aug 2012 (estimated)
- Study startJan 2012
- Primary completionSep 2012
- Study completionSep 2012
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Acute Coronary SyndromesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 3
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 304 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Hospital Erlangen
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Harald Rittger, University Hospital Erlangen
- Investigators
- Harald Rittger, MD, Principal investigator, Universitätsklinikum Erlangen, Medizinische Klinik 2, Germany
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01669382
- Sponsor's protocol ID
- Med2UKEr1/2012
- Status last verified
- Feb 2015
- First submitted
- 9 Aug 2012
- Last updated
- 4 Feb 2015
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 4 Feb 2015. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- ACCESS: A Randomized, Multicenter, Single-Blinded Trial to Compare the Extrafemoral Closure Device Exo-Seal® and the Collagen-based Intravascular Device Angio-SealTM for Arterial Puncture Site Closure.
- ClinicalTrials.gov ID
- NCT01669382
- Acronym / sponsor ID
- Med2UKEr1/2012
- Conditions
- Acute Coronary Syndromes, Stable Angina Pectoris
- Keywords
- AngioSeal, ExoSeal, PCI, puncture site
- Phase
- Phase 3
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 304 participants (actual)
- Lead sponsor
- University Hospital ErlangenUniversity, hospital or other
- Study start
- Jan 2012
- Primary completion
- Sep 2012 (actual)
- Study completion
- Sep 2012 (actual)
- First posted
- 21 Aug 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Background:
Vascular closure devices (VCD) were developed to reduce access site bleedings, to improve patients´ comfort, and to accelerate ambulation after percutaneous coronary interventions (PCI). Despite higher complications rates in earlier studies, current data suggest similar complication rates or better outcomes after the use of VCD as compared to manual compression. ExoSeal (Cordis, Warren, NJ, USA) is a new, extravascular polyglycol acid (PGA) plug which occludes the puncture channel. Whether the use of this extravascular closure device is as effective as the more widely used plug/anchor mediated devices, has not been evaluated so far.
We performed a randomized, multicentre, single-blinded trial to compare the efficacy of the extravascular closure device ExoSeal in comparison to the collagen-based plug/anchor mediated AngioSeal system.
Methods:
304 patients receiving diagnostic angiography and/or PCI will be included in three centers. Exclusion criteria are contraindications for any VCD including 1. severe calcification of the access vessel, 2. severe peripheral artery disease, 3. puncture in the origin of the profound femoral artery, 3. non-femoral sheath insertion, 4. marked tortuosity of the femoral or iliac artery, 5. marked obesity or cachexia (BMI >40 or <20) and 6. patients on continuous medication with oral anticoagulants.
After the procedure, angiography of the accessed femoral artery is performed to rule out major risk factors for retroperitoneal hemorrhage, relevant peripheral stenoses of the common or the superficial femoral artery, or a location of the puncture site in the bifurcation of the profundal femoral artery.
We hypothesise, that the use of an extravascular closure device is not inferior to an anchor/plug mediated device regarding the occurrence of the following complications: bleeding, need for vascular surgery and device failure (primary endpoints). Secondary endpoints are the occurrence of false aneurysms, severe pain (Borg ≥ 5), and hematoma ≥ 5 cm within 24 hours after insertion of the device. Power was 80%, alpha 0.05. Bleeding will be defined according to the TIMI criteria. The study is actively enrolling patients, last inclusion will take place in September 2012.
Results and Conclusions:
Outcome data including the primary endpoint (bleeding, need for vascular surgery and device failure) will be presented for the first time.
Detailed description
Introduction In patients undergoing percutaneous coronary interventions (PCI) there is a rate of vascular complications of 0.8% to 5.5% (1). Albeit femoral sheaths sizes were reduced, arterial compression and long-term dressing after PCI still bear tremendous discomfort and groin pain for the patients. Furthermore, manual compression of the puncture site should be performed until activated clotting time is below 180 seconds (2).
Therefore, vascular closure devices (VCD) were developed to reduce access site bleedings, to improve patients´ comfort, and to accelerate ambulation after PCI.
The hemostatic puncture closure device Angio-Seal (St. Jude Medical, St. Paul, MS, USA) is a collagen based plug system with an anchor in the inner vessel wall. ExoSeal (Cordis, Warren, NJ, USA) is a extravascular polyglycol acid (PGA) plug, which closes the puncture site on an extravascular basis while occluding the puncture channel.
The aim of the current, randomized study is, to evaluate the effectiveness, safety and reliability of 2 different vascular closure devices.
Methods Consecutive patients with stable angina pectoris or silent ischemia with a positive stress test will be randomized to either Angio-Seal or Exo-Seal, and included into the study after giving written informed consent.
Patients with contraindications for any VCD including 1. severe calcifications of the vessel site, 2. severe peripheral artery disease, 3. puncture in the origin of the femoral profundal artery, 3. non-femoral sheath insertion, 4. marked tortuosity of the femoral or iliac artery, and 5. marked obesity (BMI >40) or 6. cachexia (BMI <20) will be excluded from the study (3). As clinical exclusion criteria will serve: 1. any emergency intervention, 2. the use of Glycoprotein IIb/IIIa-antagonists during the intervention, and 3. patients on continuous medication with oral anticoagulants.
All patients will be loaded with either 300 mg or 600 mg of Clopidogrel or 60 mg of Prasugrel or 180 mg of Ticagrelor, followed by a maintenance dose of 75 mg or 150 mg of Clopidogrel or 5 mg or 10 mg of Prasugrel, or 90 mg of Ticagrelor prior to the intervention. After insertion of a 6 F sheath, unfractionated Heparin (UF) will be given until an activated clotting time-level (ACT) of 250 s will be achieved. The use of low -molecular weight Heparin (LMWH) according to the recommendations of the manufacturers for the purpose of anticoagulation during PCI is possible. The simultaneous use of UF and LMWH should be avoided.
Patients should receive PCI according to standard protocols (8). After the procedure, an angiography of the accessed femoral artery should be performed to rule out major risk factors for retroperitoneal hemorrhage, relevant peripheral stenoses of the common or the superficial femoral artery, or a location of the puncture site in the bifurcation of the profundal femoral artery (9). In addition, this method will identify patients with a non-femoral artery sheath insertion, for which the VCD utilization is not proven (10). Patients with strong tortuosity and/or calcification of the femoral arteries should also be excluded from the study (see exclusion criteria).
Towards the end of the intervention the ACT should be recorded again: Angio-Seal or ExoSeal may be implanted when ACT is < 300s. In patients randomized to manual compression with or without patch the sheath should be removed when the ACT is < 180s.
The use of protamine is left to the discretion of the operator. In patients randomized to either Angio-Seal or Exo-Seal the placement should be performed using the manufacturer´s recommended technique. The operator should be familiar with any device used in the study, and should have performed vascular closure with those devices at least fifty times.
After insertion of the VCD a circular groin dressing will be applied, and patients will be immobilized for 4 hours. After this, the arterial puncture site will be examined, and auscultation will be performed. If there is no relevant complication, ambulation will be initiated.
Pain during closure procedure or manual compression will be categorized according to the Borg scale, with minor pain defined as Borg < 5 and major pain as Borg ≥ 5 (13).
In patients with manual compression with or without patch, immobilization will last 8 hours. After this, inspection of the puncture site will be performed as mentioned above.
Anticoagulation either with unfractionated heparin or low molecular weight heparin will be restarted 6 hours after resolution of the dressing. On the subsequent day, ultrasound and Doppler spectral analysis of the puncture site will be performed in all patients.
Complications will be assessed as being major or minor: Major complications are defined as need for vascular surgery, false aneurysm, AV-fistula, strong pain (Borg ≥ 5), hematoma ≥ 5 cm and major bleeding, whereas minor pain, hematoma < 5 cm and new wound dressing will be classified as minor complications. Bleeding will be identified as bleeding according to the TIMI criteria (12). TIMI major bleeding is defined as hemoglobin drop > 5 g/dl (with or without an identified site), TIMI "loss no site" as a haemoglobin drop > 4 g/dl but < 5 g/dl without an identified bleeding site, and TIMI minor bleeding as a hemoglobin drop > 3 g/dl but < 5 g/dl with bleeding from a known site or spontaneous gross hematuria.
Again pain will be categorized according to the Borg scale, with minor pain defined as Borg < 5 and major pain as Borg ≥ 5 (13).
Demographic and procedural data will be prospectively collected using a standardized procedural data sheet. This includes date and type of intervention, sheath size, procedure-related drug doses, and number of previous interventions. Major or minor complications, as well as the time of events will be recorded.
Statistical analysis Randomization will be performed Statistical analyses will be performed with SPSS version 16.0 (SPSS Inc., Chicago, IL, USA). Continuous data are expressed as mean values +/- standard deviation. For comparisons between paired data the students t-test will be used. A p-value < 0.05 will be regarded as statistically significant.
Risk-benefit ratio Achieving adequate hemostasis is crucial for the prevention of access site complications in patients undergoing PCI (3). The occurrence of vascular complications was an independent predictor of nonfatal myocardial infarction or death within one year after intervention (14), and has been associated with a significant increase in mortality (15). Advanced age, female gender, pre-existing vascular disease, emergent procedures, low body surface area (4, 8, 14), diabetes, hypertension, and cigarette smoking (15, 16) are also associated with an increased bleeding risk. Therefore adequate hemostasis still remains a challenge in interventional cardiology.
The recently introduced extravascular closure device ExoSeal theoretically offer some advantages. First, there is no foreign body, which is introduced into the artery, which, once misplaced potentially can lead to an occlusion of the artery, or to inflammation or allergic reactions. In addition to that , those devices might be used in patients with common contraindications for VCD´s like calcification, peripheral artery disease and tortuosity of the artery.
Since these devices are already introduced, but not evaluated sufficiently, there is need for a randomized comparison with an established system.
The risk-benefit ratio is well on the site of benefit, since all devices are regularly used in interventional cardiology and the estimated complication rate is in the range or even lower, than those, reported in the literature.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Exo Seal system | Active comparator | Device: percutaneous coronary interventionPercutaneous coronary intervention |
| AngioSeal system | Active comparator | Device: percutaneous coronary interventionpercutaneous coronary intervention |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- all patients who receive coronary angiography/intervention with an 6 F sheath
Key exclusion criteria (7 listed)
- severe calcification of the access vessel,
- severe peripheral artery disease,
- puncture in the origin of the profound femoral artery,
- non-femoral sheath insertion,
- marked tortuosity of the femoral or iliac artery,
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| percutaneous coronary interventionAlso: Exo Seal for closure of arterial puncture siteafter the intervention patients are randomized to either Angio Seal or Exo Seal | Device | AngioSeal system, Exo Seal system |
Primary outcome
bleeding, need for vascular surgery and device failure
Time frame: 24 hours
bleeding, need for vascular surgery and device failure will be measured as primary endpoints within the first 24 hours.
1 secondary outcome
occurrence of false aneurysms, severe pain (Borg ≥ 5), and hematoma ≥ 5 cm within 24 hours after insertion of the device.
Time frame: 24 hours
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 4 Feb 2015.
Related trials for Acute Coronary Syndromes
Recruiting
CT Stress Myocardial Perfusion, Fractional Flow Reserve and Angiography in Patients With Stable Chest Pain Syndromes
Coronary Artery Disease, Chest Syndrome
Recruiting
WIN Ratio Analysis to Determine a Strategy of Non- Invasive SUpport for Respiratory Failure in the EmeRgency Department
Acute Hypoxic Respiratory Failure, Acute Respiratory Distress Syndrome (ARDS)
RecruitingPhase 4
Early Single Antiplatelet Therapy After IVUS-Guided PCI in Acute Coronary Syndrome
Acute Coronary Syndromes, STEMI
Recruiting
AI-Assisted Interpretation of Cardiac CT in the Emergency Department
Chest Pain, Acute Coronary Syndrome
Enrolling by invitation
Optical Coherence Tomography in Acute Vessel Evaluation
Ischemic Heart Disease, Ischemic Coronary Artery Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Harald Rittger, MD principal investigator
Universitätsklinikum Erlangen, Medizinische Klinik 2, Germany
3 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 3 study testing percutaneous coronary intervention in people with Acute Coronary Syndromes and Stable Angina Pectoris, run by University Hospital Erlangen at 3 sites in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 4 Feb 2015. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
bleeding, need for vascular surgery and device failure (time frame: 24 hours). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Feb 2015.