PainNCT01781650
A Comparison of Air Insufflation, Water Immersion and Water Exchange Colonoscopy in Diagnostic Patients
A study testing Air Insufflation method., Water Immersion method. and Water Exchange method. in people with Pain and Colorectal Adenomas, run by Presidio Ospedaliero Santa Barbara at 3 sites in 2 countries.
Trial summary
Water-aided method for colonoscopy can be broadly subdivided into two major categories. Water Immersion (WI), characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy, and Water Exchange (WE), characterized by suction removal of infused water predominantly during… Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Pain, Colorectal Adenomas, Colorectal Cancer
- What is being tested?
- Air Insufflation method., Water Immersion method. and Water Exchange method.
- Type of treatment
- Injection or infusion
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 288 participants
- Where
- 3 sitesin 2 countries
- Study dates
- Mar 2013to Sep 2013
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Consecutive 18 to 85 year-old first time diagnostic in-patients and outpatients agreeing to start procedure without premedication.
Who cannot join
- patient unwillingness to start the procedure without sedation/analgesia
- previous colorectal surgery
- indication for a proctosigmoidoscopy or bidirectional endoscopy
- patient refusal or inability to provide informed consent
- inadequate bowel preparation (patients unable to swallow at least ¾ of cleansing preparation, or that did have late and insufficient evacuations, or that reported the presence of residual stools in the last evacuations).
Trial locations and contacts
3 sites in 2 countries.
3 sites in 2 countries
Italy2 sites
S. Barbara Hospital
Iglesias, CA, 09016
N. S. di Bonaria Hospital
San Gavino Monreale, VS, 09037
United States1 site
Sepulveda Ambulatory Care Center, VA Greater Los Angeles Healthcare System
Los Angeles, California, 91343
About this study
Official title: A Randomized, Controlled Trial Comparing Air Insufflation, Water Immersion and Water Exchange During on Demand Sedation Colonoscopy in Diagnostic Patients
Water-aided method for colonoscopy can be broadly subdivided into two major categories. Water Immersion (WI), characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy, and Water Exchange (WE), characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy. Several studies showed that WE significantly reduces pain compared to WI and colonoscopy with traditional air insufflation (AI), increases the number of unsedated procedures and adenoma detection rate (ADR), in particular proximal ADR. This randomized controlled trial will be a direct comparison of Air Insufflation, Water Immersion and Water Exchange to test the hypothesis that WAC (particularly WE) would significantly decrease pain score during colonoscopy in diagnostic patients. Several other secondary outcomes will also be analyzed.
Read the detailed description
Introduction Water-aided methods for colonoscopy can be broadly subdivided into two major categories.
Water Immersion (WI) is characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy and Water Exchange (WE) is characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy.
Several studies showed that WE significantly reduces pain compared to WI and colonoscopy with traditional air insufflation (AI), increases the number of unsedated procedures and adenoma detection rate (ADR), in particular proximal ADR. This randomized controlled trial will be a direct comparison of Air Insufflation, Water Immersion and Water Exchange to test the hypothesis that WAC (particularly WE) would significantly decrease pain score during colonoscopy in diagnostic patients. Several other secondary outcomes will also be analyzed.
Method
Examinations will be allocated to Water Exchange, Water Immersion or Air Insufflation during the insertion phase of colonoscopy based on a computer generated random list. Procedures will be started by 6 board-certified endoscopists, three with experience in 8,000-10,000 and three with experience in 2,000-5,000 colonoscopies with AI, 285 with WI and 890 with WE overall.
High-resolution wide-angle variable-stiffness adult video colonoscopes (Olympus HD 180 series; Olympus Corp, Hamburg, Germany) will be used. Need to change to a smaller caliber colonoscope will be considered ITT failure.
Patients will have a low volume split dose bowel preparation with 2L of polyethylene glycol (PEG) solution or Sodium Picosulfate. Investigators will be blinded to the colon preparation used. Before starting the procedure, a questionnaire recording demographic data, previous abdominal surgery, co-morbidities and current medications will be administered by the endoscopists. The patients, but not endoscopists and assisting nurses, will be blinded to the method used. At discharge the patient will be asked to guess which method has been used. If no more than half of the responses are correct, patients' blinding will be considered adequate.
Colonoscopy will begin with the patients in the left lateral position, without premedication. The withdrawal phase will be identical in all arms of the study using air insufflation to obtain adequate distension of the colonic lumen for mucosal inspection, biopsy and/or polypectomy.
Patients randomized to the water-aided colonoscopy group, during the insertion phase after reaching the rectosigmoid junction, will have the colon irrigated with water at 37°C maintained with a water bath. Infusions will be performed using flushing pumps (Olympus OFP2, Olympus, Hamburg, Germany or Velocity irrigation pump, US Endoscopy, OH, USA). There will be no restriction of the overall volume of water that can be infused to get adequate lumen distention and reach the cecum. With the patient in the left lateral position water infused into the colon at the rectal sigmoid junction flows into the descending colon. The weight of the water in the left side of the colon straightens the sigmoid segment increasing the ease of insertion and reducing the risk of loop formation. The air pump will be turned off to avoid inadvertent insufflation.
Water Immersion will involve the infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Use of water as an adjunct to air insufflation to facilitate insertion and removal of infused water predominantly during withdrawal are characteristic features of WI. This traditional adjunct facilitates passage through the sigmoid colon with severe diverticulosis, speeds arrival to the splenic flexure, decreases colonic spasm, minimizes pain, and even enhances cecal intubation in previously incomplete colonoscopies.
Residual air in the colon will not be removed. The infused water and residual feces will be suctioned back only during withdrawal. Air insufflation will be allowed if the lumen cannot be seen and the endoscopists judges unsafe to advance the colonoscope. It will last no more than 10 seconds and will be recorded in the patient data sheet. If more than 3 episodes of air insufflation will be recorded the procedure will be considered ITT failure.
Water Exchange will involve complete exclusion of air insufflation, removal of residual colonic air and feces and of infused water predominantly during insertion to assist identification of the lumen. WE minimizes loop formation and decreases discomfort. By providing salvage cleansing during insertion, WE allows the colonoscopist to devote a greater proportion of the withdrawal to inspection. WE will involve the infusion of a sufficient amount of water to open the lumen of the colon to allow passage of the instrument, thus rendering the colonic lumen a slit to progress with the colonoscope. If the lumen does not open, the colonoscope will be slightly retracted and the infusion started again. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of infused water will also be applied when colonoscope insertion proceeds smoothly. Air pockets, when encountered, will be always aspirated to collapse the lumen: the absence of air space forces the colonoscopist to use water to clear residual feces and to find the way through the colon. Removal of the air also shortens the colon and takes out all the sharp turns at the flexures and redundant segments, reducing the risk of loop formation: water instillation does not elongate the colon as much as air insufflation does. In a collapsed, airless colon turbulences created at the tip of the instrument facilitate the removal by suction of residual feces adherent to the mucosa. This provides salvage cleansing during the insertion phase. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal scarce amounts of water are left to aspirate, and residual water and feces will be suctioned.
In the AI group, colonoscopy will be performed in the standard fashion, allowing for washing as needed. In all groups abdominal compression and position change were applied as needed.
Cecal intubation will be defined as passage of the tip of the colonoscope to a point proximal to the ileocecal valve with adequate visualization of the cecum and appendix orifice. A stopwatch will be used to time the procedures. Cecal intubation time will be defined as the time for passage of the colonoscope from the rectum to the cecum. The withdrawal phase will last at least 6 minutes. Polyp resection will be done during withdrawal in all groups. Time for polypectomy or biopsy will add to the total colonoscopy time. Pathology reports of all polyps will be reviewed and recorded to evaluate adenoma detection rate (ADR, defined as the proportion of subjects with at least one adenoma of any size), the location, the total number of adenomas resected per subject(ARR), and the percentage of subjects with advanced adenomas. The amount of water infused during insertion and withdrawal, the number of position changes and any adverse outcome will be recorded. Cardiopulmonary function will be monitored. Significant oxygen desaturation (<85% for >15 seconds) will be recorded. Vagal reaction will be defined as heart rate <60 beats per minute accompanied by excessive sweating, nausea and/or vomiting.
- Conditions
- Pain, Colorectal Adenomas, Colorectal Cancer
- Being tested
- Air Insufflation method., Water Immersion method., Water Exchange method.
- Keywords
- Warm Water Infusion colonoscopy, Water Immersion colonoscopy, Water Exchange colonoscopy, Painless unsedated colonoscopy, Adenoma detection rate, Adenoma resection rate
- Medical subject headings
- Pain, Colorectal Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Air Insufflation method.Other
Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure.
Water Immersion method.Other
Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if >3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal.
Water Exchange method.Other
Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned.
| Study group | Role | What they receive |
|---|---|---|
| Air insufflation method. | Active comparator | Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure. Receives: Other: Air Insufflation method. |
| Water Immersion method. | Experimental | Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if >3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal. Receives: Other: Water Immersion method. |
| Water Exchange method. | Experimental | Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned. Receives: Other: Water Exchange method. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Maximum pain score recorded during colonoscopy.
Pain will be assessed using a visual analogue scale (VAS) with a score 0=absence of pain, 2=simply "discomfort", 10=the worst possible pain. Before the procedure, an endoscopic nurse will explain the VAS scoring system to the patients. The patient will be informed that the request for pain information is not to remind the patient that the examination should be uncomfortable, but to let the colonoscopist be alerted to the need to use maneuvers to minimize discomfort (e.g. loop reduction, removal of colonic content, abdominal compression and/or change in patient position). At regular intervals during colonoscopy (e.g. every 2-3 minutes) patients will be asked about discomfort or pain. The responses will be recorded, and the maximum pain score noted.
Measured: 1 hour
Secondary outcomes (8)
Need for sedation/analgesia and its dosage.
Sedation and analgesia will be available on demand. Medication will be offered when VAS score reaches ≥2 (discomfort). Patients can accept or decline the medication. If patients agree to accept the medication, it will be given. Midazolam, no more than 5 mg per patient, will be used. When pain is reported, sedation will be started with midazolam with a single intravenous dose of 2 mg, plus incremental doses of 1 mg if the patient still continues to complain about pain. To avoid bias by the colonoscopist, sedation medication will be administered based on the patients' confirmation that the pain is no longer tolerable, and not at the discretion of the colonoscopist. No other analgesic or sedative medications will be administered. The colon segment in which patients requests sedation will be recorded.
Measured: 1 hour
Overall pain after the procedure.
After the procedure and at discharge from the Endoscopy Unit, an assistant nurse blinded to the procedure will ask patients about overall pain using the same VAS when neither the endoscopist nor the assistant nurse who performed the colonoscopy were present. Patients will be asked to quantify the degree of pain experienced and to place a mark over the VAS accordingly.
Measured: 1 hour.
Cecal intubation rate.
Cecal intubation will be defined as passage of the tip of the colonoscope beyond the ileocecal valve so that the medial wall of the cecum proximal to the ileocecal valve will be observed. This will be analyzed on an intention- to-treat basis according to group allocation.
Measured: 1 hour
Cecal intubation time.
Cecal intubation time will be defined as the time for passage of the colonoscope from the rectum to the cecum.
Measured: 1 hour
Total procedure time.
Total procedure time (including time required for polyp resection or biopsy).
Measured: 1 hour
Adenoma detection rate.
Proportion of subjects with at least one adenoma of any size.
Measured: 6 months
Adenoma resection rate.
Total number of adenomas resected per subject.
Measured: 6 months
Advanced adenoma.
Total number of advanced adenomas: diameter ≥10mm, or high grade dysplasia, or with ≥20% villous components.
Measured: 6 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted1 Feb 2013 (estimated)
- Study startMar 2013
- Primary completionSep 2013
- Study completionSep 2013
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (10)Papers the sponsor has linked to this study.
- Other trials for PainStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 288 participants (actual)
Sponsor and investigators
- Lead sponsor
- Presidio Ospedaliero Santa Barbara
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Sergio Cadoni, M.D., Presidio Ospedaliero Santa Barbara
- Investigators
- Sergio Cadoni, MD, Principal investigator, S. Barbara Hospital, Iglesias (CA), Italy
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01781650
- Sponsor's protocol ID
- PG.2013.2470
- Other IDs
- ASL07_WW-2013
- Status last verified
- Jan 2014
- First submitted
- 29 Jan 2013
- Last updated
- 15 Jan 2014
- Results posted
- No
- Data monitoring committee
- No
Publications
Leung FW, Amato A, Ell C, Friedland S, Harker JO, Hsieh YH, Leung JW, Mann SK, Paggi S, Pohl J, Radaelli F, Ramirez FC, Siao-Salera R, Terruzzi V. Water-aided colonoscopy: a systematic review. Gastrointest Endosc. 2012 Sep;76(3):657-66. doi: 10.1016/j.gie.2012.04.467.
PubMed 22898423Brocchi E, Pezzilli R, Tomassetti P, Campana D, Morselli-Labate AM, Corinaldesi R. Warm water or oil-assisted colonoscopy: toward simpler examinations? Am J Gastroenterol. 2008 Mar;103(3):581-7. doi: 10.1111/j.1572-0241.2007.01693.x. Epub 2007 Dec 12.
PubMed 18076732Rabenstein T, Radaelli F, Zolk O. Warm water infusion colonoscopy: a review and meta-analysis. Endoscopy. 2012 Oct;44(10):940-51. doi: 10.1055/s-0032-1310157. Epub 2012 Sep 17.
PubMed 22987214Leung CW, Kaltenbach T, Soetikno R, Wu KK, Leung FW, Friedland S. Water immersion versus standard colonoscopy insertion technique: randomized trial shows promise for minimal sedation. Endoscopy. 2010 Jul;42(7):557-63. doi: 10.1055/s-0029-1244231. Epub 2010 Jun 30.
PubMed 20593332Leung FW. Water exchange may be superior to water immersion for colonoscopy. Clin Gastroenterol Hepatol. 2011 Dec;9(12):1012-4. doi: 10.1016/j.cgh.2011.09.007. Epub 2011 Sep 22. No abstract available.
PubMed 21946120Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with a greater reduction of pain score - review of randomized controlled trials (RCTs) of water method colonoscopy. J Interv Gastroenterol. 2011 Jul;1(3):114-120. doi: 10.4161/jig.1.3.18510. Epub 2011 Jul 1.
PubMed 22163081Radaelli F, Paggi S, Amato A, Terruzzi V. Warm water infusion versus air insufflation for unsedated colonoscopy: a randomized, controlled trial. Gastrointest Endosc. 2010 Oct;72(4):701-9. doi: 10.1016/j.gie.2010.06.025.
PubMed 20883846Pohl J, Messer I, Behrens A, Kaiser G, Mayer G, Ell C. Water infusion for cecal intubation increases patient tolerance, but does not improve intubation of unsedated colonoscopies. Clin Gastroenterol Hepatol. 2011 Dec;9(12):1039-43.e1. doi: 10.1016/j.cgh.2011.06.031. Epub 2011 Jul 13.
PubMed 21749850Cadoni S, Falt P, Sanna S, Argiolas M, Fanari V, Gallittu P, Liggi M, Mura D, Porcedda ML, Smajstrla V, Erriu M, Leung FW. Impact of Colonoscopy Insertion Techniques on Adenoma Detection. Dig Dis Sci. 2016 Jul;61(7):2068-75. doi: 10.1007/s10620-016-4053-1. Epub 2016 Feb 5.
PubMed 26846118Cadoni S, Sanna S, Gallittu P, Argiolas M, Fanari V, Porcedda ML, Erriu M, Leung FW. A randomized, controlled trial comparing real-time insertion pain during colonoscopy confirmed water exchange to be superior to water immersion in enhancing patient comfort. Gastrointest Endosc. 2015 Mar;81(3):557-66. doi: 10.1016/j.gie.2014.07.029. Epub 2014 Sep 26.
PubMed 25262100
Study at a glance
From the registry record, last updated by the sponsor on 15 Jan 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Randomized, Controlled Trial Comparing Air Insufflation, Water Immersion and Water Exchange During on Demand Sedation Colonoscopy in Diagnostic Patients
- ClinicalTrials.gov ID
- NCT01781650
- Acronym / sponsor ID
- PG.2013.2470
- Conditions
- Pain, Colorectal Adenomas, Colorectal Cancer
- Keywords
- Warm Water Infusion colonoscopy, Water Immersion colonoscopy, Water Exchange colonoscopy, Painless unsedated colonoscopy, Adenoma detection rate, Adenoma resection rate
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 288 participants (actual)
- Lead sponsor
- Presidio Ospedaliero Santa BarbaraUniversity, hospital or other
- Study start
- Mar 2013
- Primary completion
- Sep 2013 (actual)
- Study completion
- Sep 2013 (actual)
- First posted
- 1 Feb 2013 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Water-aided method for colonoscopy can be broadly subdivided into two major categories. Water Immersion (WI), characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy, and Water Exchange (WE), characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy. Several studies showed that WE significantly reduces pain compared to WI and colonoscopy with traditional air insufflation (AI), increases the number of unsedated procedures and adenoma detection rate (ADR), in particular proximal ADR. This randomized controlled trial will be a direct comparison of Air Insufflation, Water Immersion and Water Exchange to test the hypothesis that WAC (particularly WE) would significantly decrease pain score during colonoscopy in diagnostic patients. Several other secondary outcomes will also be analyzed.
Detailed description
Introduction Water-aided methods for colonoscopy can be broadly subdivided into two major categories.
Water Immersion (WI) is characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy and Water Exchange (WE) is characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy.
Several studies showed that WE significantly reduces pain compared to WI and colonoscopy with traditional air insufflation (AI), increases the number of unsedated procedures and adenoma detection rate (ADR), in particular proximal ADR. This randomized controlled trial will be a direct comparison of Air Insufflation, Water Immersion and Water Exchange to test the hypothesis that WAC (particularly WE) would significantly decrease pain score during colonoscopy in diagnostic patients. Several other secondary outcomes will also be analyzed.
Method
Examinations will be allocated to Water Exchange, Water Immersion or Air Insufflation during the insertion phase of colonoscopy based on a computer generated random list. Procedures will be started by 6 board-certified endoscopists, three with experience in 8,000-10,000 and three with experience in 2,000-5,000 colonoscopies with AI, 285 with WI and 890 with WE overall.
High-resolution wide-angle variable-stiffness adult video colonoscopes (Olympus HD 180 series; Olympus Corp, Hamburg, Germany) will be used. Need to change to a smaller caliber colonoscope will be considered ITT failure.
Patients will have a low volume split dose bowel preparation with 2L of polyethylene glycol (PEG) solution or Sodium Picosulfate. Investigators will be blinded to the colon preparation used. Before starting the procedure, a questionnaire recording demographic data, previous abdominal surgery, co-morbidities and current medications will be administered by the endoscopists. The patients, but not endoscopists and assisting nurses, will be blinded to the method used. At discharge the patient will be asked to guess which method has been used. If no more than half of the responses are correct, patients' blinding will be considered adequate.
Colonoscopy will begin with the patients in the left lateral position, without premedication. The withdrawal phase will be identical in all arms of the study using air insufflation to obtain adequate distension of the colonic lumen for mucosal inspection, biopsy and/or polypectomy.
Patients randomized to the water-aided colonoscopy group, during the insertion phase after reaching the rectosigmoid junction, will have the colon irrigated with water at 37°C maintained with a water bath. Infusions will be performed using flushing pumps (Olympus OFP2, Olympus, Hamburg, Germany or Velocity irrigation pump, US Endoscopy, OH, USA). There will be no restriction of the overall volume of water that can be infused to get adequate lumen distention and reach the cecum. With the patient in the left lateral position water infused into the colon at the rectal sigmoid junction flows into the descending colon. The weight of the water in the left side of the colon straightens the sigmoid segment increasing the ease of insertion and reducing the risk of loop formation. The air pump will be turned off to avoid inadvertent insufflation.
Water Immersion will involve the infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Use of water as an adjunct to air insufflation to facilitate insertion and removal of infused water predominantly during withdrawal are characteristic features of WI. This traditional adjunct facilitates passage through the sigmoid colon with severe diverticulosis, speeds arrival to the splenic flexure, decreases colonic spasm, minimizes pain, and even enhances cecal intubation in previously incomplete colonoscopies.
Residual air in the colon will not be removed. The infused water and residual feces will be suctioned back only during withdrawal. Air insufflation will be allowed if the lumen cannot be seen and the endoscopists judges unsafe to advance the colonoscope. It will last no more than 10 seconds and will be recorded in the patient data sheet. If more than 3 episodes of air insufflation will be recorded the procedure will be considered ITT failure.
Water Exchange will involve complete exclusion of air insufflation, removal of residual colonic air and feces and of infused water predominantly during insertion to assist identification of the lumen. WE minimizes loop formation and decreases discomfort. By providing salvage cleansing during insertion, WE allows the colonoscopist to devote a greater proportion of the withdrawal to inspection. WE will involve the infusion of a sufficient amount of water to open the lumen of the colon to allow passage of the instrument, thus rendering the colonic lumen a slit to progress with the colonoscope. If the lumen does not open, the colonoscope will be slightly retracted and the infusion started again. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of infused water will also be applied when colonoscope insertion proceeds smoothly. Air pockets, when encountered, will be always aspirated to collapse the lumen: the absence of air space forces the colonoscopist to use water to clear residual feces and to find the way through the colon. Removal of the air also shortens the colon and takes out all the sharp turns at the flexures and redundant segments, reducing the risk of loop formation: water instillation does not elongate the colon as much as air insufflation does. In a collapsed, airless colon turbulences created at the tip of the instrument facilitate the removal by suction of residual feces adherent to the mucosa. This provides salvage cleansing during the insertion phase. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal scarce amounts of water are left to aspirate, and residual water and feces will be suctioned.
In the AI group, colonoscopy will be performed in the standard fashion, allowing for washing as needed. In all groups abdominal compression and position change were applied as needed.
Cecal intubation will be defined as passage of the tip of the colonoscope to a point proximal to the ileocecal valve with adequate visualization of the cecum and appendix orifice. A stopwatch will be used to time the procedures. Cecal intubation time will be defined as the time for passage of the colonoscope from the rectum to the cecum. The withdrawal phase will last at least 6 minutes. Polyp resection will be done during withdrawal in all groups. Time for polypectomy or biopsy will add to the total colonoscopy time. Pathology reports of all polyps will be reviewed and recorded to evaluate adenoma detection rate (ADR, defined as the proportion of subjects with at least one adenoma of any size), the location, the total number of adenomas resected per subject(ARR), and the percentage of subjects with advanced adenomas. The amount of water infused during insertion and withdrawal, the number of position changes and any adverse outcome will be recorded. Cardiopulmonary function will be monitored. Significant oxygen desaturation (<85% for >15 seconds) will be recorded. Vagal reaction will be defined as heart rate <60 beats per minute accompanied by excessive sweating, nausea and/or vomiting.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Air insufflation method. | Active comparator | Other: Air Insufflation method.Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure. |
| Water Immersion method. | Experimental | Other: Water Immersion method.Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if >3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal. |
| Water Exchange method. | Experimental | Other: Water Exchange method.Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Consecutive 18 to 85 year-old first time diagnostic in-patients and outpatients agreeing to start procedure without premedication.
Key exclusion criteria (5 listed)
- patient unwillingness to start the procedure without sedation/analgesia
- previous colorectal surgery
- indication for a proctosigmoidoscopy or bidirectional endoscopy
- patient refusal or inability to provide informed consent
- inadequate bowel preparation (patients unable to swallow at least ¾ of cleansing preparation, or that did have late and insufficient evacuations, or that reported the presence of residual stools in the last evacuations).
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Air Insufflation method.Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure. | Other | Air insufflation method. |
| Water Immersion method.Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if >3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal. | Other | Water Immersion method. |
| Water Exchange method.Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned. | Other | Water Exchange method. |
Primary outcome
Maximum pain score recorded during colonoscopy.
Time frame: 1 hour
Pain will be assessed using a visual analogue scale (VAS) with a score 0=absence of pain, 2=simply "discomfort", 10=the worst possible pain. Before the procedure, an endoscopic nurse will explain the VAS scoring system to the patients. The patient will be informed that the request for pain information is not to remind the patient that the examination should be uncomfortable, but to let the colonoscopist be alerted to the need to use maneuvers to minimize discomfort (e.g. loop reduction, removal of colonic content, abdominal compression and/or change in patient position). At regular intervals during colonoscopy (e.g. every 2-3 minutes) patients will be asked about discomfort or pain. The responses will be recorded, and the maximum pain score noted.
8 secondary outcomes
Need for sedation/analgesia and its dosage.
Time frame: 1 hour
Overall pain after the procedure.
Time frame: 1 hour.
Cecal intubation rate.
Time frame: 1 hour
Cecal intubation time.
Time frame: 1 hour
Total procedure time.
Time frame: 1 hour
Adenoma detection rate.
Time frame: 6 months
Adenoma resection rate.
Time frame: 6 months
Advanced adenoma.
Time frame: 6 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Jan 2014.
- Background: PubMed 22898423Leung FW, Amato A, Ell C, Friedland S, Harker JO, Hsieh YH, Leung JW, Mann SK, Paggi S, Pohl J, Radaelli F, Ramirez FC, Siao-Salera R, Terruzzi V. Water-aided colonoscopy: a systematic review. Gastrointest Endosc. 2012 Sep;76(3):657-66. doi: 10.1016/j.gie.2012.04.467.
- Background: PubMed 18076732Brocchi E, Pezzilli R, Tomassetti P, Campana D, Morselli-Labate AM, Corinaldesi R. Warm water or oil-assisted colonoscopy: toward simpler examinations? Am J Gastroenterol. 2008 Mar;103(3):581-7. doi: 10.1111/j.1572-0241.2007.01693.x. Epub 2007 Dec 12.
- Background: PubMed 22987214Rabenstein T, Radaelli F, Zolk O. Warm water infusion colonoscopy: a review and meta-analysis. Endoscopy. 2012 Oct;44(10):940-51. doi: 10.1055/s-0032-1310157. Epub 2012 Sep 17.
- Background: PubMed 20593332Leung CW, Kaltenbach T, Soetikno R, Wu KK, Leung FW, Friedland S. Water immersion versus standard colonoscopy insertion technique: randomized trial shows promise for minimal sedation. Endoscopy. 2010 Jul;42(7):557-63. doi: 10.1055/s-0029-1244231. Epub 2010 Jun 30.
- Background: PubMed 21946120Leung FW. Water exchange may be superior to water immersion for colonoscopy. Clin Gastroenterol Hepatol. 2011 Dec;9(12):1012-4. doi: 10.1016/j.cgh.2011.09.007. Epub 2011 Sep 22. No abstract available.
- Background: PubMed 22163081Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with a greater reduction of pain score - review of randomized controlled trials (RCTs) of water method colonoscopy. J Interv Gastroenterol. 2011 Jul;1(3):114-120. doi: 10.4161/jig.1.3.18510. Epub 2011 Jul 1.
- Background: PubMed 20883846Radaelli F, Paggi S, Amato A, Terruzzi V. Warm water infusion versus air insufflation for unsedated colonoscopy: a randomized, controlled trial. Gastrointest Endosc. 2010 Oct;72(4):701-9. doi: 10.1016/j.gie.2010.06.025.
- Background: PubMed 21749850Pohl J, Messer I, Behrens A, Kaiser G, Mayer G, Ell C. Water infusion for cecal intubation increases patient tolerance, but does not improve intubation of unsedated colonoscopies. Clin Gastroenterol Hepatol. 2011 Dec;9(12):1039-43.e1. doi: 10.1016/j.cgh.2011.06.031. Epub 2011 Jul 13.
- Derived from this study: PubMed 26846118Cadoni S, Falt P, Sanna S, Argiolas M, Fanari V, Gallittu P, Liggi M, Mura D, Porcedda ML, Smajstrla V, Erriu M, Leung FW. Impact of Colonoscopy Insertion Techniques on Adenoma Detection. Dig Dis Sci. 2016 Jul;61(7):2068-75. doi: 10.1007/s10620-016-4053-1. Epub 2016 Feb 5.
- Derived from this study: PubMed 25262100Cadoni S, Sanna S, Gallittu P, Argiolas M, Fanari V, Porcedda ML, Erriu M, Leung FW. A randomized, controlled trial comparing real-time insertion pain during colonoscopy confirmed water exchange to be superior to water immersion in enhancing patient comfort. Gastrointest Endosc. 2015 Mar;81(3):557-66. doi: 10.1016/j.gie.2014.07.029. Epub 2014 Sep 26.
Related trials for Pain
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Recruiting
Empowered Relief® for Cancer Survivors With Chronic Pain
Chronic Pain Due to Cancer, Pain Catastrophizing
RecruitingPhase 4
ESP Blocks for Posterior Spinal Fusion
Postoperative Pain
RecruitingObservational study
Pain Phenotypes in Individuals With Multiple Sclerosis
Multiple Sclerosis, Chronic Pain
Not yet recruiting
Effects of Hip Hinge Exercises on Pain, Range of Motion and Functional Disability in Non-specific Low Back Pain.
Low Back Pain
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Sergio Cadoni, MD principal investigator
S. Barbara Hospital, Iglesias (CA), Italy
3 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Air Insufflation method., Water Immersion method. and Water Exchange method. in people with Pain and Colorectal Adenomas, run by Presidio Ospedaliero Santa Barbara at 3 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 15 Jan 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in Italy, United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Maximum pain score recorded during colonoscopy. (time frame: 1 hour). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01781650, which also lists 10 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jan 2014.