Inertial Sensors Used to Learn Manipulation

A study testing Real Time Feedback and Traditional Learning Method in people with Medical Education, run by University of Malaga.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Background Context: no studies have been identified to analyse the effect of real time feedback (using inertial sensors) on physiotherapy students learning the art of posterior-anterior thoracic manipulation (PATM). Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Medical Education
What is being tested?
Real Time Feedback and Traditional Learning Method
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
64 participants
Where
No sites listed yet
Study dates
Feb 2012to Sep 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Participants did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

Who cannot join

  • Refusal to participate in the study

About this study

Official title: EFFECT OF REAL-TIME FEEDBACK THROUGH INERTIAL SENSORS IN LEARNING POSTEROANTERIOR THORACIC MANIPULATION

  • Background Context: no studies have been identified to analyse the effect of real time feedback (using inertial sensors) on physiotherapy students learning the art of posterior-anterior thoracic manipulation (PATM).
  • Purpose: to study the effect caused by real-time feedback on the learning process for PATM, comparing two undergraduate physiotherapy student groups. Hypothesis: significant differences will exist in the execution parameters of manipulation among students receiving real-time feedback versus those who do not.
  • Study Design/Setting: longitudinal, pre-post intervention.
  • Patient Sample: Sixty-one undergraduate physiotherapy students were divided randomly into two groups, G1 (n = 31) (group without feedback in real time) and G2 (n = 30) (group with real-time feedback).
  • Outcome Measures: time, displacement and velocity and improvement (only between groups) to reach maximum peak, to reach minimum peak from maximum peak, total manipulation time.
  • Methods: two groups of physiotherapy students learned PATM, one using a traditional method and the other using real-time feedback (inertial sensor). Measures were obtained pre- and post-intervention. Intragroup pre- and post-intervention and intergroup post-intervention scores were calculated. An analysis of the measures' stability was developed through an ICC (1,2).
  • Results: the values of ICC ranged from 0.881 to 0.997. Statistically significant differences were found in all variables analysed (intra- and inter-group) in favour of G2.
  • Conclusions: the learning process for posterior-anterior thoracic manipulation is facilitated when the student receives real-time feedback.
Being tested
Real Time Feedback, Traditional Learning Method
Keywords
Spinal Manipulation, Teaching, Thoracic Vertebrae, Feedback

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Real Time FeedbackDevice

    Before beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution

  • Traditional Learning MethodDevice

    Two expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8.

Study groups in NCT01911338
Study groupRoleWhat they receive
Real Time FeedbackExperimentalBefore beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution
Receives: Device: Real Time Feedback
Tradicional Learning MethodActive comparatorTwo expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8
Receives: Device: Traditional Learning Method

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change from displacement maximum peak (seconds)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

  2. Change from Time to reach maximum peak (seconds)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

  3. Change from Displacement between maximum and minimum peak (milimitres)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

  4. Change from Total manipulation time (seconds)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

  5. Change from Velocity to reach maximum peak (degrees per second)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

  6. Change from Time to reach peak minimum from maximum peak (seconds)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

  7. Change from Velocity to reach minimum peak from maximum peak (degress/second)

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

    Measured: baseline; post-education; 24 weeks follow up

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Jul 2013 (estimated)
  2. Study startFeb 2012
  3. Primary completionJun 2012
  4. Study completionSep 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Allocation
Randomised
Intervention model
Crossover
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
64 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01911338
Sponsor's protocol ID
ACuesta07072013
Status last verified
Jul 2013
First submitted
23 Jul 2013
Last updated
4 Dec 2014
Results posted
No
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Real Time Feedback and Traditional Learning Method in people with Medical Education, run by University of Malaga.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Dec 2014. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change from displacement maximum peak (seconds) (time frame: baseline; post-education; 24 weeks follow up). The study lists 7 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Dec 2014.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in