AzTrials
AzTrials

Inner Ear MalformationsNCT02011867

A New Cochlear Implant Electrode For Inner Ear Malformations

A study testing Cork Electrode in people with Inner Ear Malformations, run by Hacettepe University.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). Read more about this study

Who is it for?
Any age
Conditions the study is for
Inner Ear Malformations
What is being tested?
Cork Electrode
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
No sites listed yet
Study dates
May 2013to Nov 2013
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Must have an inner ear malformation
  • Must meet the criteria for cochlear implantation

Who cannot join

  • Prior cochlear implantation surgery

About this study

Official title: A New Cochlear Implant Electrode With A "Cork" Type Stopper For Inner Ear Malformations

The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). It was used in 50 patients with different inner ear malformations. Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF (cerebrospinal fluid) pulsation and had to be revised. Both patients had no more CSF fistula.

CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new cochlear implant electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode.

Read the detailed description

Gusher in inner ear malformations is common in patients with incomplete partition type-I, and III. It is also common in less severe form as oozing in incomplete partition type II and large vestibular aqueduct. It is important to prevent CSF escape around the cochlear implant electrode to prevent meningitis.

The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). It was used in 50 patients with different inner ear malformations.

Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF pulsation and had to be revised. Both patients had no more CSF fistula.

CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new cochlear implant electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode.

Being tested
Cork Electrode
Keywords
Inner Ear Malformations, Gusher, Cochlear Implantation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Cork ElectrodeDevice

    Also called MedEl Cork Electrode

Study groups in NCT02011867
Study groupRoleWhat they receive
Cork ElectrodeExperimentalUsing Cork Electrode for CSF leak prevention for inner ear malformations.
Receives: Device: Cork Electrode

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. CSF leak

    Occurrence of CSF leak after the surgery.

    Measured: Up to 1 year

Secondary outcomes (1)
  1. Meningitis

    Having meningitis due to CSF leak or connection to the middle ear after surgery.

    Measured: Up to 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Dec 2013 (estimated)
  2. Study startMay 2013
  3. Primary completionSep 2013
  4. Study completionNov 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02011867
Sponsor's protocol ID
GO-13/315
Status last verified
Dec 2013
First submitted
30 Nov 2013
Last updated
13 Dec 2013
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Cork Electrode in people with Inner Ear Malformations, run by Hacettepe University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Dec 2013. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

CSF leak (time frame: Up to 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Dec 2013.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in