AzTrials
AzTrials

CardiomyopathyVFNCT02027883

Comparison of VF Induction Techniques During Medtronic ICD Implant (VF) (ICD)

A study testing Nominal T shock setting and Educated T shock setting in people with Cardiomyopathy, run by James Merrill at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

As the indications for Implantable Cardioverter Defibrillator implantation expand, minimizing implant time is critical. Also, patients receiving biventricular ICDs are sometimes more unstable and minimization of sedation time is crucial. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiomyopathy
What is being tested?
Nominal T shock setting and Educated T shock setting
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteUnited States
Study dates
Jan 2011to Aug 2012
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • All patients undergoing Medtronic ICD or Cardiac Resynchronization Therapy-Defibrillator implant (initial implant or generator replacement) will be included.

Who cannot join

  • Any patient who is medically unstable and testing is deemed unsafe by physician will be excluded from this study.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Wellmont CVA Heart Institute

    Kingsport, Tennessee, 37660

Other trials in United States

About this study

Official title: Comparison of Ventricular Fibrillation Induction Techniques During Medtronic Implantable Cardioverter Defibrillator Implant

As the indications for Implantable Cardioverter Defibrillator implantation expand, minimizing implant time is critical. Also, patients receiving biventricular ICDs are sometimes more unstable and minimization of sedation time is crucial. Multiple induction attempts, with a 1-Joule shock, can cause disruption in lead position. Therefore limiting the number of attempts will allow for better lead stability throughout the procedure and a more straightforward implant process.

Investigator proposes a detailed documentation of success rates from various Ventriculart Fibrillation induction methods during implant of Medtronic defibrillation capable devices.

Read the detailed description

Our clinical experience has found that attempts to induce patients receiving ICDs at implant using the nominal Medtronic T-shock settings are not always effective at inducing ventricular fibrillation. When this results, a change to the parameters for T-shock is made before reattempting to induce ventricular fibrillation in patients undergoing ICD implantation.

Another available induction method is 50 Hz Burst. "The 50 Hz Burst induction is designed to induce VF by delivering a rapid burst of pacing pulses. The amplitude and pulse width of these pulses are selectable, but the pacing interval is fixed at 20 ms."2 If multiple attempts using the T-shock method are unsuccessful, 50 Hz Burst provides an additional method for inducing ventricular fibrillation. It is a less desirable method since it can result in very fine VF that is difficult to identify the initiation of possibly resulting in longer times in VF causing higher defibrillation threshold or in undersensing due to the fine nature of the rhythm.

T-shock has been found to be a fast and reliable method for inducing ventricular fibrillation in ICD implants. Greater success of inducing ventricular fibrillation using the T-shock method has been found when the energy of the T-shock was higher and the coupling interval was shorter. In addition, increasing the shock strength increases the window of vulnerability. For the T-shock method to be most efficient, initial success at inducing ventricular fibrillation, and therefore a reduced number of attempts, is important. This requires a better understanding of the optimal programmed settings for the initial T-shock induction attempt.

Moreover, in recent years, ICD indications have grown to include primary prevention patients. These patients may have different vulnerable periods than patients previously evaluated to develop Medtronic nominal settings.

Our clinical experience has found that the nominal T-shock settings are only effective at inducing ventricular fibrillation approximately seventy-five percent of the time. However, a detailed collection of success rates has not been performed.

Conditions
Cardiomyopathy
Being tested
Nominal T shock setting, Educated T shock setting
Keywords
Defibrillators, Ventricular Fibrillation Induction Testing
Medical subject headings
Cardiomyopathies

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Nominal T shock settingDevice

    Also called Medtronic ICDs

    Nominal Parameter Set 1 Programming Values for EnTrust

  • Educated T shock settingDevice

    Also called Medtronic ICDs

    Experimental Parameter Set 2 Programming Values

Study groups in NCT02027883
Study groupRoleWhat they receive
Nominal ParameterActive comparatorNominal T shock setting
Receives: Device: Nominal T shock setting
Experimental ParameterExperimentalEducated T shock setting
Receives: Device: Educated T shock setting

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sustained Ventricular Fibrillation

    The primary endpoint is the successful induction of sustained ventricular fibrillation.

    Measured: 2 hours

Secondary outcomes (1)
  1. Factors

    Determine if any pre-implant patient demographics are factors impacting T-shock success according to parameter settings.

    Measured: 2 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Jan 2014 (estimated)
  2. Study startJan 2011
  3. Primary completionAug 2012
  4. Study completionAug 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
100 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02027883
Sponsor's protocol ID
VF Induction
Acronym
VF
Status last verified
Apr 2018
First submitted
31 Dec 2013
Last updated
22 May 2018
Data monitoring committee
No
Individual data sharing
No

Publications

  • Bardy G, Mehra R, Johnson G, Kudenchuk P, Dolack G, Poole J, Hofer B: Low energy pulsing on the T-wave: A new programming method for intentional, device mediated induction of ventricular fibrillation for defibrillation testing. PACE 15(4, Pt II): 562, 1992.

  • Bhandari AK, Isber N, Estioko M, Ziccardi T, Cannom DS, Park Y, Lerman RD, Prejean C, Sun GW. Efficacy of low-energy T wave shocks for induction of ventricular fibrillation in patients with implantable cardioverter defibrillators. J Electrocardiol. 1998 Jan;31(1):31-7. doi: 10.1016/s0022-0736(98)90004-8.

    PubMed 9533375
  • Marquis DR Reference Manual, Medtronic, Inc.

  • Mitchell L, Yee R, Talajic M, Newman D, Sheldon R, Kerr C, Kus T, Boyle A, Canadian Jewel PCD Investigators: Low-energy, T-wave synchronous, interval shock for rapid, reliable ventricular fibrillation induction by an implantable cardioverter defibrllattor. PACE, 17(4, Pt II): 851, 1994.

  • Swartz J, Stanton M, DeGroot P, Mehra R: Influence of T-wave shock energy on ventricular fibrillation vulnerability in humans. JACC 1995 Conference Abstracts: 214A, 1995.

Questions about this trial

What is this clinical trial studying?

A study testing Nominal T shock setting and Educated T shock setting in people with Cardiomyopathy, run by James Merrill at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 May 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 30 Dec 2014). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sustained Ventricular Fibrillation (time frame: 2 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02027883, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 May 2018; AzTrials last refreshed its copy on 31 Oct 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.