Various systems to measure intravesical and intrarectal pressure during urodynamic testing; especially cystometry, exist. Water filled tube -systems are the most commonly used and should be regarded as the contemporary standard. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Incontinence
What is being tested?
lower urinary tract dysfunction
Type of treatment
Surgery or procedure
How many people
36 participants
Where
1 siteNetherlands
Study dates
Dec 2013to Dec 2014
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients scheduled (on the basis of contemporary clinical standards and protocols) for standard urodynamic investigation.

Who may be able to join

  • (All necessary:)
  • Female gt18 years
  • Scheduled for urodynamic investigation on the basis of contemporary standards and guidelines, because of signs and symptoms of lower urinary tract dysfunction.
  • May perform (not excluded) intermittent (self) catheterisation.
  • No signs of voiding dysfunction (routine outpatient max flow above 20 millilitre per second without postvoid residual)
  • No signs of bladder /pelvic pain syndrome
Show all 14Show fewer
  • OR:
  • (All necessary)
  • Male or female gt18years
  • Complete spinal cord injury, level above T12, or meningomyelocele unable to void and significantly reduced or no pelvic floor, urethral or bladder sensation.
  • May have (not excluded) 'sacral sparing'; some residual anal sensation
  • Scheduled for urodynamic investigation on the basis of contemporary standards and guidelines, because of signs and symptoms of lower urinary tract dysfunction or because of routine (protocol, guidelines) follow -up.
  • Usually: performing intermittent (self) catheterisation); not excluded.
  • May have (not excluded) indwelling catheter.

Who cannot join

  • Unwilling or unfit to sign informed consent.
  • American Society of Anesthesiologists -score gt2; karnovsky lt80percent.
  • Male with normal lower urinary tract sensation.
  • Women with signs of voiding dysfunction.
  • Patients included in scientific studies (for other reasons).

Trial locations and contacts

1 site in 1 country.

Peter FW Rosier, MD PhD contact

+31887558081

p.f.w.m.rosier@umcutrecht.nl

Ruud JL Bosch, Prof. contact

+31887558081

J.L.H.R.Bosch@umcutrecht.nl

Netherlands1 site, 1 recruiting
  • University Medical Center Utrecht

    Utrecht, 3584CX

    Peter FW Rosier, MD PhD

    Recruiting

Other trials in Netherlands

About this study

Official title: In Vivo Comparison of Air Charged Catheters With Water Filled Catheters for Intravesical and Intrarectal Pressures Recording During Urodynamic Study

Various systems to measure intravesical and intrarectal pressure during urodynamic testing; especially cystometry, exist. Water filled tube -systems are the most commonly used and should be regarded as the contemporary standard. A water filled system is however sensitive to tube and or patient movement artefacts and prone to erroneous calibration. Air charged catheters are less sensitive to patient and especially tubing- movements, and calibrate easier. However, in vitro tests have demonstrated that air charged catheters respond somewhat slower and relatively damped, especially to rapid pressure changes as in (simulated) coughing, in comparison with water filled systems. The clinical relevance of these observations is unknown.

This is a study to compare the technical reliability and clinical applicability of the two types of catheter systems for cystometry in a synchronous double catheter testing procedure in a prospective group or patients scheduled for urodynamic investigation.

Read the detailed description

Study design: Patient cohort, acute experiment, mono -center synchronous double urodynamic catheter technique study.

Study population: Adult female patients and male or female patients with spinal cord injury or meningomyelocele unable to void, scheduled for urodynamic investigation on the basis of contemporary standards and guidelines, because of signs and or symptoms of lower urinary tract dysfunction.

Intervention: Synchronous double catheter urodynamic testing; Standard filling cystometry with both air-charged ánd water filled catheter pairwise inserted, and connected to the registry equipment.

Main study parameters/endpoints: Difference of intravesical pressure increment maximum during filling cystometry between the two systems.

Primary hypothesis to test: The average difference as well as the average absolute difference of maximum water pressure (standard system) and maximum air pressure (comparator) are both 0 (zero).

There is no per-protocol for follow up of the patients.

Conditions
Incontinence
Being tested
lower urinary tract dysfunction
Keywords
urodynamic investigation, lower urinary tract dysfunction, catheter, air-charged, water filled

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • lower urinary tract dysfunctionProcedure or surgery

    Also called T-doc air charged catheters.

    Urodynamic investigation with a double (two systems: air-charged and water filled) catheter system

Study groups in NCT02030340
Study groupRoleWhat they receive
Testing Lower urinary tract dysfunctionAll patients with lower urinary tract dysfunction where urodynamic diagnosis is required according to standards and (international) practice guidelines will have a synchronous double system (combination of air-charged and water filled) urodynamic test.
Receives: Procedure: lower urinary tract dysfunction

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The difference between the water filled catheter recorded and simultaneously air charged catheter recorded maximum pressure (amplitude)during the bladder filling phase of urodynamic test.

    Null hypothesis: the (absolute mean) difference between the water filled catheter recorded and simultaneously air charged catheter recorded maximum pressure (amplitude) observed with a dominant detrusor pressure event during urodynamic filling as obtained with both systems is close to zero.

    Measured: acute comparison during one test with two types of catheter

Secondary outcomes (1)
  1. responses to relevant pressure events: end fill pressure, maximum contraction pressure, maximum pressure at overactive detrusor contraction and maximum cough pressure.

    to test the clinical feasibility (-mean absolute- pressure responses differences) of the air charged system, against the contemporary clinical standard. Perfect feasibility of air charged catheter system is achieved when the measured pressures are equal (difference zero) to the water filled system in all performed measurements in all situations.

    Measured: acute comparison during one test with two types of catheter

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Jan 2014 (estimated)
  2. Study startDec 2013
  3. Primary completionAug 2014 (estimated)
  4. Study completionDec 2014 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Enrolment
36 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02030340
Sponsor's protocol ID
AC-WF
Other IDs
T-Doc-LLC
Acronym
ACWF
Status last verified
Jan 2014
First submitted
6 Mar 2013
Last updated
8 Jan 2014
Results posted
No
Data monitoring committee
Yes

Publications

  • Rosier PF, Gajewski JB, Sand PK, Szabo L, Capewell A, Hosker GL; International Consultation on Incontinence 2008 Committee on Dynamic Testing. Executive summary: The International Consultation on Incontinence 2008--Committee on: "Dynamic Testing"; for urinary incontinence and for fecal incontinence. Part 1: Innovations in urodynamic techniques and urodynamic testing for signs and symptoms of urinary incontinence in female patients. Neurourol Urodyn. 2010;29(1):140-5. doi: 10.1002/nau.20764.

    PubMed 19693949

Questions about this trial

What is this clinical trial studying?

An observational study of Incontinence, run by UMC Utrecht at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 14 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 8 Jan 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Peter FW Rosier, MD PhD (+31887558081, p.f.w.m.rosier@umcutrecht.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The difference between the water filled catheter recorded and simultaneously air charged catheter recorded maximum pressure (amplitude)during the bladder filling phase of urodynamic test. (time frame: acute comparison during one test with two types of catheter). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02030340, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jan 2014.