AzTrials
AzTrials

Airway MorbidityLTSNCT02300337

Comparison of Reduced Cuff-pressure of the Laryngeal Tube Under General Anesthesia

A study testing Reduce Cuff pressure in people with Airway Morbidity, run by Johannes Gutenberg University Mainz at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Optimization the cuff pressure of the laryngeal tube (LT) in relation of the mechanical ventilation, and the reduction of potential leakage mucosal trauma. Comparison of the tightness of LT between the filling volume specified by the manufacturer (connectors are color coded syringe and blocker), 60cmH₂O, 50cmH₂O… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Airway Morbidity
What is being tested?
Reduce Cuff pressure
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteGermany
Study dates
Nov 2014to Jan 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥ 18 Years
  • No concurrent participation in another study
  • capacity to consent
  • Present written informed consent of the research participant
  • Elective surgery under general anesthesia
  • Height> 150cm

Who cannot join

  • Age <18 years
  • Existing pregnancy
  • Lack of consent
  • inability to consent
  • emergency patients
  • Emergency situations in the context of a Difficult Airway Management
Show all 11Show fewer
  • ASA classification> 3
  • situations where the possibility of accumulated gastric contents
  • Indications for intubation with endotracheal tube
  • Height <150cm
  • Participation in another study

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • Department of Anesthesiology,Prof. C. Werner, Universitätsmedizin of the JG University

    Mainz, Rhineland-Palatinate, D55131

Other trials in Germany

About this study

Official title: Comparative Study of the Tightness of the Laryngeal Tube Under Mechanical Ventilation Before and After Reduction of Cuff Pressure on 60cmH₂O, 50cmH₂O, 40cmH₂O or 30cmH₂O

Optimization the cuff pressure of the laryngeal tube (LT) in relation of the mechanical ventilation, and the reduction of potential leakage mucosal trauma. Comparison of the tightness of LT between the filling volume specified by the manufacturer (connectors are color coded syringe and blocker), 60cmH₂O, 50cmH₂O, 40cmH₂Ound 30cmH₂O. The measurement of the leakage occurs in ml / kg body weight.

Read the detailed description

The ventilation of both cuffs of the laryngeal tube by using the color coding of syringe and connector is a simple, fast and easy way to stabilize the tube and secure seal against the surrounding tissue.

The user of this method has only knowledge of the volume (ml), with which the cuff is vented, but not over the cuff pressure (cmH₂O) itself.

Permanently high pressures can cause to a lesions to necrosis in the adjacent tissue, on the other hand, the material of the bulging cuff fits less well the anatomy of the patient, leading to leaks in the breathing circuit.

Studies of pediatric anesthesia show that on 40cmH₂O reduces the volume of the leak in the laryngeal mask airway by reducing the cuff pressure and the ventilation is improved in sequence.

In the proposed study, the volume of leakage at the fill volume specified by the manufacturer (color coding), 60cmH₂O, 50cmH₂O, 40cmH₂O and 30cmH₂O to be captured.

Being tested
Reduce Cuff pressure
Keywords
laryngeal tube, cuff pressure, leakage, laryngeal mask

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Reduce Cuff pressureDevice

    We reduce the Cuff Pressure from the LTS-D (Laryngeal Tube suction) from 60 to 50 to 40 to 30cmH2O and measure the Delta from Inspiration to Expiration Tidalvolume (Delta Vt). The Delta Vt shows the actual leakage.

Study groups in NCT02300337
Study groupRoleWhat they receive
Reduce Cuff PressureExperimentalCuff Pressure difference between inspiration and expiration is measured.
Receives: Device: Reduce Cuff pressure

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison of Leakage between the different Cuff Pressure

    We want to measure the tightness of the reduced Cuff Pressure

    Measured: < 5 Minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Nov 2014 (estimated)
  2. Study startNov 2014
  3. Primary completionJan 2015
  4. Study completionJan 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02300337
Sponsor's protocol ID
JohannesGU
Acronym
LTS
Status last verified
Jan 2015
First submitted
20 Nov 2014
Last updated
19 Jan 2015
Results posted
No
Data monitoring committee
No

Publications

  • Janig C, Marquardt S, Dietze T, Nitsche T. Laryngeal tube placement on manikin by laypersons: is there a possibility for 'public access airway management'? Eur J Emerg Med. 2014 Feb;21(1):65-8. doi: 10.1097/MEJ.0b013e328364a152.

    PubMed 23887642
  • Kriege M, Alflen C, Eisel J, Ott T, Piepho T, Noppens RR. Evaluation of the optimal cuff volume and cuff pressure of the revised laryngeal tube "LTS-D" in surgical patients. BMC Anesthesiol. 2017 Feb 2;17(1):19. doi: 10.1186/s12871-017-0308-4.

    PubMed 28152975

Questions about this trial

What is this clinical trial studying?

A study testing Reduce Cuff pressure in people with Airway Morbidity, run by Johannes Gutenberg University Mainz at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Jan 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison of Leakage between the different Cuff Pressure (time frame: < 5 Minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02300337, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Jan 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in