Congenital Heart DiseaseNCT02326649
Noninvasive Measurement of CO Using Impedance Cardiography in Patients With CHD
An observational study of Congenital Heart Disease, run by University of California, San Diego at 1 site in United States.
Trial summary
This study will test the capability of a non-invasive instrument (the PhysioFlow impedance cardiography instrument) to measure cardiac output in patients with congenital heart disease (CHD). Read more about this study
- Who is it for?
- Any age
- Conditions the study is for
- Congenital Heart Disease
- What is being tested?
- Physioflow
- Type of treatment
- Medical device
- How many people
- 21 participants
- Where
- 1 siteUnited States
- Study dates
- Dec 2014to Mar 2016
- Phase
- Observational
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Study population: Any patient with congenital heart disease that is undergoing cardiac MRI without anesthesia
Who may be able to join
- Any form of congenital heart disease
- Any age
Who cannot join
- Subjects with significant clinical skin reactions to electrodes such as excessive pain and/or skin inflammation, or significant previous skin reaction
- Subjects who are not able to provide consent
- Subjects with pacemaker
Trial locations and contacts
1 site in 1 country.
United States1 site
Rady Children's Hospital
San Diego, California, 92123
About this study
Official title: Noninvasive Measurement of Cardiac Output Using Impedance Cardiography in Patients With Congenital Heart Disease
This study will test the capability of a non-invasive instrument (the PhysioFlow impedance cardiography instrument) to measure cardiac output in patients with congenital heart disease (CHD). This instrument works by placing electrodes on the skin of a patient and measuring electrical impedance through the chest, which is proportional to blood volume and blood flow at any given time. The instrument has been validated in patients with structurally normal hearts, but in the only two studies using it for patients with CHD, it was deemed too inaccurate for clinical use. The manufacturer of the device would require access to data on the patients in order to improve its accuracy, and that has not been feasible thus far. This study would begin by comparing cardiac output based on the PhysioFlow monitor to standard techniques, then after possible changes to the instrument to enhance accuracy, would test the instrument again in the same way.
Read the detailed description
The measurement of cardiac output (CO) is important for a wide variety of patients under multiple conditions. At present, gold standard techniques for measurement of CO include velocity encoded phase contrast MRI. Both of these techniques are valid in patients with structural CHD. Disadvantages of these techniques include the requirement of significant time and expertise, and the high cost and anesthesia requirement. Accurate, non-invasive tools to measure CO could be extremely valuable for patients with CHD that require one-time of continuous monitoring of CO, such as during surgery, in intensive care settings, during other diagnostic testing, and during different physiologic states such as sleep and exercise. This study would begin by comparing cardiac output based on the PhysioFlow monitor to cardiac outout by MRI.
Impedance cardiography is performed by placing electrodes on the thorax and neck to measure electrical impedance over time. Cardiac output is derived from these measurements. The technique has been studied, validated, and used extensively in adults and has also been shown to be valid in children with structurally normal hearts. In contrast, recent studies of children with CHD have shown a relatively poor agreement between impedance cardiography and both thermodilution technique and velocity encoded phase contrast MRI. The reasons for the poor agreement in CHD patients is not yet understood. There are proprietary algorithms in each impedance device that use the raw data to calculate and report cardiac output. If the physiologic and/or anatomic differences of patients with CHD require changing the algorithm within each system to account for such differences, that needs to be done to each system. In order to do this, owners of any given device (PhysioFlow, NeuMeDx Inc. in this case) need access to the raw data in order to alter the algorithm. This study will involve a concerted effort between investigators at RCHSD, UCSD, and NeuMeDx
- Conditions
- Congenital Heart Disease
- Being tested
- Physioflow
- Keywords
- cardiac output
- Medical subject headings
- Heart Defects, Congenital
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
PhysioflowDevice
impedance cardiography instrument that measures cardiac output non-invasively
| Study group | Role | What they receive |
|---|---|---|
| CHD patients undergoing cardiac MRI without sedation | Not described Receives: Device: Physioflow |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean Difference in Stroke Volume Between CMR and SMIC
Mean difference in stroke volume (SV) between CMR and SMIC measurements in ml
Measured: 2 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Dec 2014 (estimated)
- Study startDec 2014
- Primary completionFeb 2016
- Study completionMar 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Congenital Heart DiseaseStudies of the same condition, open and under way.
- More trials run by University of California, San DiegoThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 21 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of California, San Diego
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Dr. Christopher Davis, University of California, San Diego
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02326649
- Sponsor's protocol ID
- 140550
- Status last verified
- Feb 2017
- First submitted
- 15 Dec 2014
- Last updated
- 12 Apr 2017
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 12 Apr 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Noninvasive Measurement of Cardiac Output Using Impedance Cardiography in Patients With Congenital Heart Disease
- ClinicalTrials.gov ID
- NCT02326649
- Acronym / sponsor ID
- 140550
- Conditions
- Congenital Heart Disease
- Keywords
- cardiac output
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 21 participants (actual)
- Lead sponsor
- University of California, San DiegoUniversity, hospital or other
- Study start
- Dec 2014
- Primary completion
- Feb 2016 (actual)
- Study completion
- Mar 2016 (actual)
- First posted
- 29 Dec 2014 (estimated)
- Results
- Posted 12 Apr 2017
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study will test the capability of a non-invasive instrument (the PhysioFlow impedance cardiography instrument) to measure cardiac output in patients with congenital heart disease (CHD). This instrument works by placing electrodes on the skin of a patient and measuring electrical impedance through the chest, which is proportional to blood volume and blood flow at any given time. The instrument has been validated in patients with structurally normal hearts, but in the only two studies using it for patients with CHD, it was deemed too inaccurate for clinical use. The manufacturer of the device would require access to data on the patients in order to improve its accuracy, and that has not been feasible thus far. This study would begin by comparing cardiac output based on the PhysioFlow monitor to standard techniques, then after possible changes to the instrument to enhance accuracy, would test the instrument again in the same way.
Detailed description
The measurement of cardiac output (CO) is important for a wide variety of patients under multiple conditions. At present, gold standard techniques for measurement of CO include velocity encoded phase contrast MRI. Both of these techniques are valid in patients with structural CHD. Disadvantages of these techniques include the requirement of significant time and expertise, and the high cost and anesthesia requirement. Accurate, non-invasive tools to measure CO could be extremely valuable for patients with CHD that require one-time of continuous monitoring of CO, such as during surgery, in intensive care settings, during other diagnostic testing, and during different physiologic states such as sleep and exercise. This study would begin by comparing cardiac output based on the PhysioFlow monitor to cardiac outout by MRI.
Impedance cardiography is performed by placing electrodes on the thorax and neck to measure electrical impedance over time. Cardiac output is derived from these measurements. The technique has been studied, validated, and used extensively in adults and has also been shown to be valid in children with structurally normal hearts. In contrast, recent studies of children with CHD have shown a relatively poor agreement between impedance cardiography and both thermodilution technique and velocity encoded phase contrast MRI. The reasons for the poor agreement in CHD patients is not yet understood. There are proprietary algorithms in each impedance device that use the raw data to calculate and report cardiac output. If the physiologic and/or anatomic differences of patients with CHD require changing the algorithm within each system to account for such differences, that needs to be done to each system. In order to do this, owners of any given device (PhysioFlow, NeuMeDx Inc. in this case) need access to the raw data in order to alter the algorithm. This study will involve a concerted effort between investigators at RCHSD, UCSD, and NeuMeDx
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| CHD patients undergoing cardiac MRI without sedation | – | Device: Physioflow |
Who may qualify
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
- Study population
- Any patient with congenital heart disease that is undergoing cardiac MRI without anesthesia
Key inclusion criteria (2 listed)
- Any form of congenital heart disease
- Any age
Key exclusion criteria (3 listed)
- Subjects with significant clinical skin reactions to electrodes such as excessive pain and/or skin inflammation, or significant previous skin reaction
- Subjects who are not able to provide consent
- Subjects with pacemaker
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Physioflowimpedance cardiography instrument that measures cardiac output non-invasively | Device | CHD patients undergoing cardiac MRI without sedation |
Primary outcome
Mean Difference in Stroke Volume Between CMR and SMIC
Time frame: 2 hours
Mean difference in stroke volume (SV) between CMR and SMIC measurements in ml
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 12 Apr 2017.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Congenital Heart Disease
Not yet recruiting
Autologous Thymus Transplant in Children With Congenital Heart Disease: A Pilot Study
Congenital Heart Disease (CHD)
RecruitingPhase 1
A Study of SGT-212 Gene Therapy in Friedreich's Ataxia
Friedreich's Ataxia (FA)
RecruitingObservational study
The CACHE Study: Coronary Artery Care in HaEmophilia
Haemophilia, Cardiovascular Diseases
RecruitingObservational study
Essen Amyloidosis Registry
Amyloidosis; Systemic, Amyloidosis Cardiac
RecruitingPhase 3
Trial Investigating the Efficacy and Safety of Weekly Lonapegsomatropin Compared to Daily Somatropin in Children and Adolescents With Short Stature or Growth Failure Due to Growth Hormone Sufficient Disorders
Turner Syndrome, Short Stature Homeobox Gene Mutation
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Congenital Heart Disease, run by University of California, San Diego at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 12 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 12 Apr 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean Difference in Stroke Volume Between CMR and SMIC (time frame: 2 hours). It is what the study was designed to measure, not a finding.