AzTrials
AzTrials

Cardiac OutputNCT02438228

Cardiac Output by Nine Different Pulse Contour Algorithms

A study testing Cardiac output measurement in people with Cardiac Output, run by University Hospital Schleswig-Holstein at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The aim of the present study is to compare accuracy and precision of Cardiac Output (CO) by nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiac Output
What is being tested?
Cardiac output measurement
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteGermany
Study dates
Nov 2014to Nov 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients > 18 years of age with a left ventricular ejection fraction ≥ 0.5.
  • Patients undergoing coronary artery bypass grafting.

Who cannot join

  • Patients <18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study.
  • Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • Berthold Bein

    Hamburg, Free and Hanseatic City of Hamburg, 20099

Other trials in Germany

About this study

Official title: Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution

The aim of the present study is to compare accuracy and precision of Cardiac Output (CO) by nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB).

Read the detailed description

After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.

After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.

Conditions
Cardiac Output
Being tested
Cardiac output measurement
Keywords
cardiac output, transpulmonary thermodilution, pulse contour analysis, G09.330.380.124

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Cardiac output measurementOther

    Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.

Study groups in NCT02438228
Study groupRoleWhat they receive
Cardiac output measurementOtherNot described
Receives: Other: Cardiac output measurement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution

    Measured: After induction of anesthesia until the end of surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 May 2015 (estimated)
  2. Study startNov 2014
  3. Primary completionNov 2015
  4. Study completionNov 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02438228
Sponsor's protocol ID
AZ-138
Status last verified
Feb 2016
First submitted
29 Apr 2015
Last updated
11 Feb 2016
Results posted
No
Data monitoring committee
Yes

Publications

  • Schloglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014 May;61(5):452-79. doi: 10.1007/s12630-014-0135-8. Epub 2014 Mar 19.

    PubMed 24643474
  • Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010 Nov;111(5):1180-92. doi: 10.1213/ANE.0b013e3181f08a5b. Epub 2010 Aug 24.

    PubMed 20736431
  • Suehiro K, Tanaka K, Funao T, Matsuura T, Mori T, Nishikawa K. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth. 2013 Aug;111(2):170-7. doi: 10.1093/bja/aet022. Epub 2013 Mar 10.

    PubMed 23479677
  • Smetkin AA, Hussain A, Kuzkov VV, Bjertnaes LJ, Kirov MY. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Br J Anaesth. 2014 Jun;112(6):1024-31. doi: 10.1093/bja/aet489. Epub 2014 Feb 13.

    PubMed 24531685
  • Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514.

    PubMed 25233178
  • Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009 Jun;15(3):244-8. doi: 10.1097/MCC.0b013e32832b7083.

    PubMed 19417642
  • Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Biomed Res Int. 2016;2016:3468015. doi: 10.1155/2016/3468015. Epub 2016 Dec 28.

    PubMed 28116294

Questions about this trial

What is this clinical trial studying?

A study testing Cardiac output measurement in people with Cardiac Output, run by University Hospital Schleswig-Holstein at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Feb 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution (time frame: After induction of anesthesia until the end of surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02438228, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Feb 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.