AzTrials
AzTrials

KeratoconusNCT02475343

A Novel Method to Assess the Cornea Biomechanical Properties With Schiotz Tonometer

A study testing Schiotz tonometer, UVA/riboflavin and femto-LASIK in people with Keratoconus, run by Zhiwei Li at 1 site in China.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This study aims to use Schiotz tonometer to evaluate the corneal biomechanical properties. The administration of Schiotz tonometer is according to the routine protocol which is use to measure intra-ocular pressure. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Keratoconus
What is being tested?
Schiotz tonometer, UVA/riboflavin and femto-LASIK
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1,000 participants
Where
1 siteChina
Study dates
Feb 2015to Jun 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • People without the disease mentioned in exclusion criteria part.

Who cannot join

  • Patients with ocular diseases including keratitis, conjunctivitis, history of chronic eye/systemic diseases except myopia and keratoconus, history of ocular surgery except LASIK, pregnant or lactating females.

Trial locations and contacts

1 site in 1 country.

China1 site, 1 recruiting
  • Shandong Provincial Hospital

    Jinan, Shandong

    Lihua Wang, MD, wang_glasses@163.com

    Recruiting

Other trials in China

About this study

Official title: A Novel Method to Assess the Cornea Biomechanical Properties With Schiotz

This study aims to use Schiotz tonometer to evaluate the corneal biomechanical properties. The administration of Schiotz tonometer is according to the routine protocol which is use to measure intra-ocular pressure. The results obtained from Schiotz tonometer will be compared with results obtained from ORA and/or Corvis.

Read the detailed description

Schiotz tonometer, since it firstly be developed more than 100 years ago by Hjalmar Schiotz, has been regarded as a classical method to evaluate intraocular pressure (IOP). In present study, we aims to measure the corneal biomechanical properties with schiotz tonometer and elucidate the clinical significance of this novel measurement. The corneal biomechanical property was calculated with subtracting the value displayed under loaded weight 5.5g from that under loaded weight 7.5g. We named the corneal biomechanical properties obtained with schiotz tonometer as Mulee factor, and the formulation is Mulee factor=value under loaded weight 7.5g (Value 7.5G)-value under loaded weight 5.5g (Value 5.5G).

Conditions
Keratoconus
Being tested
Schiotz tonometer, UVA/riboflavin, femto-LASIK, Tomey SP-100 Pchymeter , Topolyzer Vario, Topcon CT-80, Topcon, Japan
Medical subject headings
Keratoconus

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Schiotz tonometerDevice

    The corneal biomechanical properties will be measured using a Schiotz tonometer with routine manipulation protocol.This measurement will be used in normal people, keratoconic patients, patients received keratoplasty.

  • UVA/riboflavinDevice

    The UVA/riboflavin corneal crosslinking will be applied using a UV-X lamp (Peschke Meditrade GmbH, Switzerland) with routine manipulation protocol (3mW/cm2, 365nm, 30 minutes).This treatment will be used in keratoconic patients.

  • femto-LASIKDevice

    The keratoplasty mainly include femto-LASIK (Laser in situ keratomileusis), which will be applied using a Wavelight FS200 and Wavelight EX500 Excimer Laser (Alcon Inc. USA.).The keratoplasty will be applied in patients who would like to receive the surgery.

  • Tomey SP-100 Pchymeter , Topolyzer VarioDevice

    Cornea thickness will be measured with a pachymeter (Tomey SP-100 Pchymeter, Japan); cornea topography will be measured with Topolyzer Vario (Allegro, Wavelight GmBH, Germany); anterior chamber depth, white to white, and ocular axis length will be measured using a IOL master (Carl Zeiss Meditec, Germany). These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.

  • Topcon CT-80, Topcon, JapanDevice

    Vision acuity will be measured with a decimal visual chart; IOP (Intra-ocular pressure) will be measured with a tonometer (Topcon CT-80, Topcon, Japan) , fundoscopy examination will be apllied with a direct ophthalmoscopy, slit lamp examination will be applied with a slit lamp. These examinations will be used in normal people, keratoconic patients, patients received keratoplasty.

  • Corvis-STDevice

    Cornea biomechanical properties will be measured with a ocular response analyzer (Reichert, USA.) and/or a Corvis-ST (Oculus, Germany).These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.

Study groups in NCT02475343
Study groupRoleWhat they receive
ControlExperimentalPeople without keratoconus, history of ocular surgery, and other diseases mentioned in exclusion criteria. Normal people will receive treatment or measurement including: Schiotz tonometer measurement, UVA/riboflavin corneal crosslinking, Keratoplasty, Ocular morphology measurement,and routine ophthalmic examination.
Receives: Device: Schiotz tonometer; Device: UVA/riboflavin; Device: femto-LASIK; Device: Tomey SP-100 Pchymeter , Topolyzer Vario; Device: Topcon CT-80, Topcon, Japan; Device: Corvis-ST
Keratoconic patientsExperimentalPatients with keratoconus.Keratoconic patients will receive treatment or measurement including:Schiotz tonometer measurement, UVA/riboflavin corneal crosslinking,Ocular morphology measurement,and routine ophthalmic examination.
Receives: Device: Schiotz tonometer; Device: UVA/riboflavin; Device: Tomey SP-100 Pchymeter , Topolyzer Vario; Device: Topcon CT-80, Topcon, Japan; Device: Corvis-ST
Patients received keratoplastyExperimentalPatients received keratoplasty. Patients received keratoplasty will receive treatment or measurement including:Schiotz tonometer measurement,Keratoplasty, Ocular morphology measurement,and routine ophthalmic examination..
Receives: Device: Schiotz tonometer; Device: femto-LASIK; Device: Tomey SP-100 Pchymeter , Topolyzer Vario; Device: Topcon CT-80, Topcon, Japan; Device: Corvis-ST

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The Mulee factor obtained with Schiotz tonometer as a measure of cornea biomechanical property

    Mulee factor= Value displayed with Schiotz tonometer under 7.5g load-Value displayed with Schiotz tonometer under 5.5g load

    Measured: up to 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jun 2015 (estimated)
  2. Study startFeb 2015
  3. Primary completionMay 2016 (estimated)
  4. Study completionJun 2016 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Investigator
Enrolment
1,000 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02475343
Sponsor's protocol ID
No.018
Status last verified
Nov 2015
First submitted
28 May 2015
Last updated
18 Nov 2015
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Schiotz tonometer, UVA/riboflavin and femto-LASIK in people with Keratoconus, run by Zhiwei Li at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 18 Nov 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Zhiwei Li, MD. (+86-18053106729, zhiweiovs@hotmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The Mulee factor obtained with Schiotz tonometer as a measure of cornea biomechanical property (time frame: up to 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Nov 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in