HypoxemiaNCT02523586
Comparison of Pharyngeal Oxygen Delivery by Different Oxygen Masks
An observational study of Hypoxemia and Trauma, run by Oregon Health and Science University at 1 site in United States.
Trial summary
The intent of this study is to determine the difference in pharyngeal oxygen concentration in patients who have a natural airway (not intubated) using commonly available oxygen delivery systems. Read more about this study
- Who is it for?
- Ages 18 to 70 yearsHealthy volunteers can take part
- Conditions the study is for
- Hypoxemia, Trauma, Acute Myocardial Infarction
- What is being tested?
- Oxygen administration
- How many people
- 14 participants
- Where
- 1 siteUnited States
- Study dates
- May 2015to Jun 2016
- Phase
- Observational
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 70 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: Subjects who meet the inclusion criteria and none of the exclusion criteria who are to undergo a procedure not requiring general anesthesia.
Who may be able to join
- 18 to 70 years of age
- Male and female volunteers
- ASA physical status I, II and III
- Capable and willing to provide written informed consent in English
Who cannot join
- Acute cardiopulmonary disease, as defined by blood pressure greater than 150/90, HR greater than 120 and room air oxygen saturation less than 92.
- Allergy to lidocaine or adhesive tape
- History or physical exam finding of nasal polyps
- Currently taking oral or parenteral anticoagulant medications (other than aspirin)
- History of frequent nose bleeds
- Current symptoms of nasal congestion
- Physical examination findings of rales or wheezing
- Facial hair that prevents forming a seal with an anesthesia mask
Trial locations and contacts
1 site in 1 country.
United States1 site
Oregon Health and Science University
Portland, Oregon, 97239
About this study
The intent of this study is to determine the difference in pharyngeal oxygen concentration in patients who have a natural airway (not intubated) using commonly available oxygen delivery systems.
The investigators will test the hypothesis that oxygen concentration during the period of inspiration (FiO2) in the pharynx is dependent on oxygen delivery system design, even at high flow (15 liters/minute) oxygen delivery. Specific measurements include oxygen concentration at subjects' lips and pharynx when breathing 100% oxygen and room air via a simple mask, non-rebreather mask, OxyMaskTM, and anesthesia mask with headstrap and Jacson Rees circuit.
A mean difference of 10% pharyngeal FiO2 between any of the masks will be considered clinically important. The expected standard deviation of the within-subject FiO2 is 3.5%. With a significance criterion of 0.05, 10 subjects would provide more than 90% power to detect a mean difference of 10%.
Read the detailed description
Oxygen therapy refers to the administration of oxygen at higher concentrations than room air. According to the most recent American Association for Respiratory Care Clinical Practice Guidelines, indications for supplemental oxygen include hypoxemia, severe trauma, acute myocardial infarction, short term therapy, and postoperative recovery. Though there are few contraindications to oxygen therapy, potential complications exist, including ventilatory depression in hypercarbic patients, absorption atelectasis, and oxygen toxicity (particularly in some patients receiving specific chemotherapeutic agents). In the spontaneously breathing hypoxemic patient without an endotracheal tube, it is important to be able to deliver high concentrations of oxygen in order to either avoid intubation or bridge to intubation. A number of oxygen delivery devices are available that have different properties that make them useful for different situations.
Variable performance (low-flow) systems: Low-flow devices are variable performance because the delivered flow rates are less than the patient's peak inspiratory flow rate (PIFR) and the oxygen is diluted by room air entrained from around the devices. Higher PIFR (e.g. respiratory distress) results in a decrease in the FiO2 delivered through a variable performance device. Rebreathing of carbon dioxide is also possible with low-flow masks at lower oxygen flow rates. Variable performance systems include the nasal cannula, simple mask, partial rebreathing mask, and non-rebreathing mask.
Nasal cannulas are commonly used for stable patients because they are more comfortable, less irritating to skin, and less anxiety-inducing than masks; they also allow the patient to eat, talk, and use incentive spirometry. Nasal cannula can provide 24-40% FiO2 with flow-rates up to 6 L/min. The simple mask is commonly used in the immediate postoperative setting for supplemental oxygen. Several small holes on either side of the mask as well as the imperfect seal allow room air to be entrained and exhaled air to escape from the mask. Simple masks can provide 35-50% FiO2 at flow-rates 5-10 L/min.1 Long-term use of masks can lead to skin irritation and pressure sores.The partial rebreather consists of a simple mask with a reservoir bag, and provides 40-70% FiO2 at flow-rates 6-10 L/min.1 The partial rebreather is no longer used at many hospitals because the range of oxygen delivery can be encompassed by the simple mask and the non-rebreather. The non-rebreathing mask is similar to the partial rebreather but includes one-way valves that prevent exhaled air from returning to the reservoir bag. The non-rebreather can deliver 60-80% FiO2 at 10-15 L/min.1
Fixed performance (high-flow) systems: By delivering oxygen at a flow rate greater than PIFR, fixed performance systems make it possible to provide a specified FiO2 throughout the respiratory cycle. The two commonly used devices are the Venturi mask and OxyMaskTM. Venturi masks use the Bernoulli principle to deliver oxygen at high flows through a Venturi valve that has a narrow constriction followed by a wider area with vents that entrain room air. Because of the relative ease of use and consistent oxygen delivery, they are useful for patients with COPD or others with chronic hypoxemia. The Venturi mask is able to deliver an FiO2 of 24-50%.1 Venturi masks will not be tested in this study.
The OxyMaskTM is a relatively new device that uses the Venturi diffuser with a five-pronged open mask design, which allows the patient to talk and may cause less claustrophobia than the more closed masks. OxyMaskTM is able to deliver 25-80% FiO2 at flow rates of 1.5-15 L/min. A closed mask with a perfect seal could theoretically deliver 100% FiO2. For the purposes of this study, a Jackson Rees circuit will be used to deliver oxygen to an anesthesia mask. The Jackson Rees circuit (also called the Mapleson F circuit) is routinely used during transport to deliver oxygen from the oxygen tank to intubated patients. This circuit consists of tubing connected to a manual ventilation bag that can be squeezed to deliver pressurized gas flow to the patient. The bag is equipped with an adjustable pressure limiting valve, which allows the provider to control the pressure delivered by squeezing the bag.
Measurement of FiO2: It has been established that FiO2 achieved with nasal cannula does not differ significantly whether the subject breathes through their mouth or nose. This property has not been established for masks. With a closed mask, FiO2 achieved would also be the same regardless of mouth or nose-breathing. With an open mask, the assumption must be made that oxygen concentration is equal at the nose and the mouth in order to ensure equivalence of mouth and nose-breathing. Also, previous studies on oxygen delivery systems have used a variety of methods for measuring FiO2. From a review of the literature of the oxygen delivery devices discussed above, only the nasal cannula has been studied by measurement of oxygen at the level of the pharynx, whereas the other masks have been studied by measurement of oxygen at the lips.
Study Rationale: The studies on OxyMaskTM determined FiO2 based on gas sampled at the lips. However, due to the possibility of gas mixing and/or nasal breathing with the open mask design, it is unclear if the gas sampled at the lips is the same gas that arrives at the trachea, which is the most clinically relevant location. The gas inspired from the trachea is what is actually seen by the alveoli and participates in oxygenation of the blood. Gas mixing would seem more likely with an open mask design such as the OxyMask. A study comparing pharyngeal FiO2 between masks would more accurately demonstrate the effective FiO2 than the currently available data. This in turn, will better inform perioperative clinicians of the best approach to maximize oxygen delivery to our critically ill post-operative patients who require supplemental oxygen to treat or prevent systemic hypoxia.
Study Design: The investigators will measure steady state FiO2 in the pharynx and at the lips simultaneously on each subject as they undergo each of the following oxygen delivery conditions sequentially: 1) room air; 2) high flow oxygen and simple mask; 3) high flow oxygen and non-rebreather mask; 4) high flow oxygen and OxyMask; and 5) high flow oxygen and anesthesia mask with head-strap and Jackson Rees circuit.
Study Population: The study will include up to 20 subjects. A mean difference of 10% pharyngeal FiO2 between any of the masks will be considered clinically important. The expected standard deviation of the within-subject FiO2 is 3.5%. With a significance criterion of 0.05, 10 subjects would provide more than 90% power to detect a mean difference of 10%.
Setting: The study will take place in a fully equipped operating room with an anesthesia machine that has been approved for patient use by Infection Control and Biomedical Engineering. It is located in the South OR area of Kohler Pavilion at OHSU and is equipped with the Datex Ohmeda anesthesia machine and Poet Gas Analyzer that will be used for the study. The study will be conducted after hours to avoid any conflict with surgical patient care. The oxygen sensors will be calibrated before each subject is tested.
Recruitment: Subjects will be recruited from OHSU's perioperative service. Advertisement flyers will be distributed in each operating room location.
Consent: The consent process will be undertaken by individuals with appropriate human subjects protection and HIPPA education, and performed in person on the OHSU campus or on the phone. Subjects may withdraw from the study at any time.
Procedures: The subjects will each participate on one study day and will require one hour per subject. Subjects will remain NPO for at least 6 hours prior to their study period. Subject characteristics will be recorded. The anesthesia machine will be turned on and the oxygen sensor on the gas analyzer will be calibrated. Baseline vital signs (HR, BP, SpO2) will be measured. FEV1 and FVC will be measured with the anesthesia machine and a standard circuit, using the Y-piece as the mouthpiece. The following protocol for gas sampling will be used: One gas sampling line will be attached at one end to the gas analyzer and at the other end to an 8 French suction catheter, which will be lubricated with 2% lidocaine jelly. This nasal catheter will be inserted through a nare, with the tip position immediately behind the uvula. Placement will be confirmed by visualizing the tip of the catheter using a penlight and having the subject open the mouth widely and say, "Ah." If required, a tongue depressor will be used. If the catheter cannot be visualized, then it will be inserted to a standard depth of 9-10cm. The nasal catheter will be taped to the subject's face. A second gas sampling line will be taped to the subject's face and positioned so that sampling occurs at the patient's lips. After placement of the two sampling catheters is confirmed, the subject will breathe room air normally for 90 seconds and FiO2 will be measured over a period of 30 seconds. The subject will not be instructed whether to use their nose or mouth to breathe, since patients in the hospital typically not instructed which way to breathe. Afterward, testing of the various oxygen masks will be performed with oxygen set at high flow (15L/min) through simple mask, non-rebreather mask, OxyMask, and anesthesia mask with headstrap and Jackson Rees circuit. Since the auxiliary oxygen dial on the anesthesia machine only goes up to 10L/min, a 15L/min adjustable oxygen valve will be attached directly to the main oxygen supply line in the operating room. After placement of each mask and starting oxygen high flow, the subject will breathe normally for 90 seconds and then FiO2 will be measured over the next 30 seconds, similarly to the room air control. At the end of each trial period, each subject will be asked to take a single vital capacity breath (starting with maximum exhalation and followed by maximum inhalation). Between testing of each mask, there will be a five minute period of breathing room air as a washout period and to confirm stability of hemodynamic status (measurement of BP and HR). Demographic data to be obtained includes height (cm), weight (kg), age, gender, and self-declared ethnicity. Blood pressure, heart rate, and oxygen saturation will be recorded at baseline and prior to and following each mask-trial. Baseline FEV1/FVC measurement will be conducted on all patients prior to initiating the study and recorded. FiO2 data will be downloaded digitally from the gas analyzer to an excel spreadsheet. If this is not possible, then oxygen percentage will be manually recorded during each breath to determine the range of oxygen percentages (minimal and maximal) during both phases of ventilation, during the 30 second measurement period. Respiratory rate during measurement time will also be recorded. At the end of the 30 second sampling period, a final measurement will be taken during a forced vital capacity breath.
Data Analysis: Phase of ventilation will be defined using the capnography tracing, which is displayed concurrently with measurement of inspired oxygen. Maximal and minimal oxygen concentration will be averaged for inspiration, during the 30 second mask breathing trial, for each subject. These values will be averaged across the group for each intervention to define statistics for the entire group. Values recorded during normal tidal volume ventilation will be analyzed separately from values recorded during each forced vital capacity ventilation. The Analysis of Variance test and appropriate post-hoc analysis will be used to determine the difference between FiO2 administered by each mask tested.
- Conditions
- Hypoxemia, Trauma, Acute Myocardial Infarction
- Being tested
- Oxygen administration
- Keywords
- oxygen concentration, oxygen therapy, oxygen delivery, oxygen masks
- Medical subject headings
- Hypoxia, Wounds and Injuries
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Oxygen administrationOther
Also called Simple Mask, Non-rebreather mask, OxyMaskTM, Anesthesia mask with headstrap and Jackson-Rees circuit
Subjects will breathe room air for 90 seconds. FiO2 will be measured for 30 seconds. Testing of masks will be performed with oxygen set at high flow through simple mask, non-rebreather mask, OxyMaskTM, and anesthesia mask with headstrap and Jackson-Rees circuit. After placement of each mask and starting oxygen, subjects will breathe normally for 90 seconds. FiO2 will be measured for 30 seconds. After each trial, subjects will take one vital capacity breath. Between testing each mask, subjects will breathe room air for 5 minutes to confirm stability of hemodynamic status. Respiratory rate and FiO2 data will be recorded during each breath to determine oxygen percentages. At the end of the 30 second sampling period, a final measurement will be taken during a forced vital capacity breath.
| Study group | Role | What they receive |
|---|---|---|
| Oxygen administration | Via Simple Mask, Via Non-rebreather, Via OxyMask, Via Anesthesia Mask (head strap and J-R circuit), Via Room Air Receives: Other: Oxygen administration |
What is being measured
The primary outcome is the main question the study is designed to answer.
Oxygen Concentration Measured at the Lips by Datex-Ohmeda Differential Paramagnetic Sensor
After placement of each mask and starting oxygen high flow, the subject will breathe normally for 90 seconds and then FiO2 will be measured over the next 30 seconds. At the end of each trial period, each subject will be asked to take a single vital capacity breath (starting with maximum exhalation and followed by maximum inhalation). Between testing of each mask, there will be a 5 minute period of breathing room air as a washout period to confirm stability of hemodynamic status (measurement of blood pressure and heart rate).
Measured: The subjects will each participate on one study day and will require 1 hour per subject.
Oxygen Concentration Measured at the Oropharyngeal Location by Nasal Catheter
After placement of each mask and starting oxygen high flow, the subject will breathe normally for 90 seconds and then FiO2 will be measured over the next 30 seconds. At the end of each trial period, each subject will be asked to take a single vital capacity breath (starting with maximum exhalation and followed by maximum inhalation). Between testing of each mask, there will be a 5 minute period of breathing room air as a washout period to confirm stability of hemodynamic status (measurement of blood pressure and heart rate).
Measured: The subjects will each participate on one study day and will require 1 hour per subject.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Aug 2015 (estimated)
- Study startMay 2015
- Primary completionJun 2016
- Study completionJun 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for HypoxemiaStudies of the same condition, open and under way.
- More trials run by Oregon Health and Science UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case crossover
- Time perspective
- Prospective
- Enrolment
- 14 participants (actual)
Sponsor and investigators
- Lead sponsor
- Oregon Health and Science University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Jeffrey Kirsch, Oregon Health and Science University
- Investigators
- Jeffrey Kirsch, MD, Principal investigator, Oregon Health and Science University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02523586
- Sponsor's protocol ID
- 11231
- Status last verified
- Oct 2017
- First submitted
- 20 Jul 2015
- Last updated
- 1 Aug 2018
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Publications
Kallstrom TJ; American Association for Respiratory Care (AARC). AARC Clinical Practice Guideline: oxygen therapy for adults in the acute care facility--2002 revision & update. Respir Care. 2002 Jun;47(6):717-20. No abstract available.
PubMed 12078655ACCP-NHLBI National Conference on Oxygen Therapy. Chest. 1984 Aug;86(2):234-47. doi: 10.1378/chest.86.2.234. No abstract available.
PubMed 6744963Paul JE, Hangan H, Hajgato J. The OxyMask() development and performance in healthy volunteers. Med Devices (Auckl). 2009;2:9-17. Epub 2008 Dec 11.
PubMed 22915909KORY RC, BERGMANN JC, SWEET RD, SMITH JR. Comparative evaluation of oxygen therapy techniques. JAMA. 1962 Mar 10;179:767-72. doi: 10.1001/jama.1962.03050100021005. No abstract available.
PubMed 14458557Wettstein RB, Shelledy DC, Peters JI. Delivered oxygen concentrations using low-flow and high-flow nasal cannulas. Respir Care. 2005 May;50(5):604-9.
PubMed 15871753Yanez ND, Fu AY, Treggiari MM, Kirsch JR. Oropharyngeal Oxygen Concentration Is Dependent on the Oxygen Mask System and Sampling Location. Respir Care. 2020 Jan;65(1):29-35. doi: 10.4187/respcare.07027. Epub 2019 Sep 10.
PubMed 31506337
Study at a glance
From the registry record, last updated by the sponsor on 1 Aug 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison of Pharyngeal Oxygen Delivery by Different Oxygen Masks
- ClinicalTrials.gov ID
- NCT02523586
- Acronym / sponsor ID
- 11231
- Conditions
- Hypoxemia, Trauma, Acute Myocardial Infarction
- Keywords
- oxygen concentration, oxygen therapy, oxygen delivery, oxygen masks
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 14 participants (actual)
- Lead sponsor
- Oregon Health and Science UniversityUniversity, hospital or other
- Study start
- May 2015
- Primary completion
- Jun 2016 (actual)
- Study completion
- Jun 2016 (actual)
- First posted
- 14 Aug 2015 (estimated)
- Results
- Posted 1 Aug 2018
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The intent of this study is to determine the difference in pharyngeal oxygen concentration in patients who have a natural airway (not intubated) using commonly available oxygen delivery systems.
The investigators will test the hypothesis that oxygen concentration during the period of inspiration (FiO2) in the pharynx is dependent on oxygen delivery system design, even at high flow (15 liters/minute) oxygen delivery. Specific measurements include oxygen concentration at subjects' lips and pharynx when breathing 100% oxygen and room air via a simple mask, non-rebreather mask, OxyMaskTM, and anesthesia mask with headstrap and Jacson Rees circuit.
A mean difference of 10% pharyngeal FiO2 between any of the masks will be considered clinically important. The expected standard deviation of the within-subject FiO2 is 3.5%. With a significance criterion of 0.05, 10 subjects would provide more than 90% power to detect a mean difference of 10%.
Detailed description
Oxygen therapy refers to the administration of oxygen at higher concentrations than room air. According to the most recent American Association for Respiratory Care Clinical Practice Guidelines, indications for supplemental oxygen include hypoxemia, severe trauma, acute myocardial infarction, short term therapy, and postoperative recovery. Though there are few contraindications to oxygen therapy, potential complications exist, including ventilatory depression in hypercarbic patients, absorption atelectasis, and oxygen toxicity (particularly in some patients receiving specific chemotherapeutic agents). In the spontaneously breathing hypoxemic patient without an endotracheal tube, it is important to be able to deliver high concentrations of oxygen in order to either avoid intubation or bridge to intubation. A number of oxygen delivery devices are available that have different properties that make them useful for different situations.
Variable performance (low-flow) systems: Low-flow devices are variable performance because the delivered flow rates are less than the patient's peak inspiratory flow rate (PIFR) and the oxygen is diluted by room air entrained from around the devices. Higher PIFR (e.g. respiratory distress) results in a decrease in the FiO2 delivered through a variable performance device. Rebreathing of carbon dioxide is also possible with low-flow masks at lower oxygen flow rates. Variable performance systems include the nasal cannula, simple mask, partial rebreathing mask, and non-rebreathing mask.
Nasal cannulas are commonly used for stable patients because they are more comfortable, less irritating to skin, and less anxiety-inducing than masks; they also allow the patient to eat, talk, and use incentive spirometry. Nasal cannula can provide 24-40% FiO2 with flow-rates up to 6 L/min. The simple mask is commonly used in the immediate postoperative setting for supplemental oxygen. Several small holes on either side of the mask as well as the imperfect seal allow room air to be entrained and exhaled air to escape from the mask. Simple masks can provide 35-50% FiO2 at flow-rates 5-10 L/min.1 Long-term use of masks can lead to skin irritation and pressure sores.The partial rebreather consists of a simple mask with a reservoir bag, and provides 40-70% FiO2 at flow-rates 6-10 L/min.1 The partial rebreather is no longer used at many hospitals because the range of oxygen delivery can be encompassed by the simple mask and the non-rebreather. The non-rebreathing mask is similar to the partial rebreather but includes one-way valves that prevent exhaled air from returning to the reservoir bag. The non-rebreather can deliver 60-80% FiO2 at 10-15 L/min.1
Fixed performance (high-flow) systems: By delivering oxygen at a flow rate greater than PIFR, fixed performance systems make it possible to provide a specified FiO2 throughout the respiratory cycle. The two commonly used devices are the Venturi mask and OxyMaskTM. Venturi masks use the Bernoulli principle to deliver oxygen at high flows through a Venturi valve that has a narrow constriction followed by a wider area with vents that entrain room air. Because of the relative ease of use and consistent oxygen delivery, they are useful for patients with COPD or others with chronic hypoxemia. The Venturi mask is able to deliver an FiO2 of 24-50%.1 Venturi masks will not be tested in this study.
The OxyMaskTM is a relatively new device that uses the Venturi diffuser with a five-pronged open mask design, which allows the patient to talk and may cause less claustrophobia than the more closed masks. OxyMaskTM is able to deliver 25-80% FiO2 at flow rates of 1.5-15 L/min. A closed mask with a perfect seal could theoretically deliver 100% FiO2. For the purposes of this study, a Jackson Rees circuit will be used to deliver oxygen to an anesthesia mask. The Jackson Rees circuit (also called the Mapleson F circuit) is routinely used during transport to deliver oxygen from the oxygen tank to intubated patients. This circuit consists of tubing connected to a manual ventilation bag that can be squeezed to deliver pressurized gas flow to the patient. The bag is equipped with an adjustable pressure limiting valve, which allows the provider to control the pressure delivered by squeezing the bag.
Measurement of FiO2: It has been established that FiO2 achieved with nasal cannula does not differ significantly whether the subject breathes through their mouth or nose. This property has not been established for masks. With a closed mask, FiO2 achieved would also be the same regardless of mouth or nose-breathing. With an open mask, the assumption must be made that oxygen concentration is equal at the nose and the mouth in order to ensure equivalence of mouth and nose-breathing. Also, previous studies on oxygen delivery systems have used a variety of methods for measuring FiO2. From a review of the literature of the oxygen delivery devices discussed above, only the nasal cannula has been studied by measurement of oxygen at the level of the pharynx, whereas the other masks have been studied by measurement of oxygen at the lips.
Study Rationale: The studies on OxyMaskTM determined FiO2 based on gas sampled at the lips. However, due to the possibility of gas mixing and/or nasal breathing with the open mask design, it is unclear if the gas sampled at the lips is the same gas that arrives at the trachea, which is the most clinically relevant location. The gas inspired from the trachea is what is actually seen by the alveoli and participates in oxygenation of the blood. Gas mixing would seem more likely with an open mask design such as the OxyMask. A study comparing pharyngeal FiO2 between masks would more accurately demonstrate the effective FiO2 than the currently available data. This in turn, will better inform perioperative clinicians of the best approach to maximize oxygen delivery to our critically ill post-operative patients who require supplemental oxygen to treat or prevent systemic hypoxia.
Study Design: The investigators will measure steady state FiO2 in the pharynx and at the lips simultaneously on each subject as they undergo each of the following oxygen delivery conditions sequentially: 1) room air; 2) high flow oxygen and simple mask; 3) high flow oxygen and non-rebreather mask; 4) high flow oxygen and OxyMask; and 5) high flow oxygen and anesthesia mask with head-strap and Jackson Rees circuit.
Study Population: The study will include up to 20 subjects. A mean difference of 10% pharyngeal FiO2 between any of the masks will be considered clinically important. The expected standard deviation of the within-subject FiO2 is 3.5%. With a significance criterion of 0.05, 10 subjects would provide more than 90% power to detect a mean difference of 10%.
Setting: The study will take place in a fully equipped operating room with an anesthesia machine that has been approved for patient use by Infection Control and Biomedical Engineering. It is located in the South OR area of Kohler Pavilion at OHSU and is equipped with the Datex Ohmeda anesthesia machine and Poet Gas Analyzer that will be used for the study. The study will be conducted after hours to avoid any conflict with surgical patient care. The oxygen sensors will be calibrated before each subject is tested.
Recruitment: Subjects will be recruited from OHSU's perioperative service. Advertisement flyers will be distributed in each operating room location.
Consent: The consent process will be undertaken by individuals with appropriate human subjects protection and HIPPA education, and performed in person on the OHSU campus or on the phone. Subjects may withdraw from the study at any time.
Procedures: The subjects will each participate on one study day and will require one hour per subject. Subjects will remain NPO for at least 6 hours prior to their study period. Subject characteristics will be recorded. The anesthesia machine will be turned on and the oxygen sensor on the gas analyzer will be calibrated. Baseline vital signs (HR, BP, SpO2) will be measured. FEV1 and FVC will be measured with the anesthesia machine and a standard circuit, using the Y-piece as the mouthpiece. The following protocol for gas sampling will be used: One gas sampling line will be attached at one end to the gas analyzer and at the other end to an 8 French suction catheter, which will be lubricated with 2% lidocaine jelly. This nasal catheter will be inserted through a nare, with the tip position immediately behind the uvula. Placement will be confirmed by visualizing the tip of the catheter using a penlight and having the subject open the mouth widely and say, "Ah." If required, a tongue depressor will be used. If the catheter cannot be visualized, then it will be inserted to a standard depth of 9-10cm. The nasal catheter will be taped to the subject's face. A second gas sampling line will be taped to the subject's face and positioned so that sampling occurs at the patient's lips. After placement of the two sampling catheters is confirmed, the subject will breathe room air normally for 90 seconds and FiO2 will be measured over a period of 30 seconds. The subject will not be instructed whether to use their nose or mouth to breathe, since patients in the hospital typically not instructed which way to breathe. Afterward, testing of the various oxygen masks will be performed with oxygen set at high flow (15L/min) through simple mask, non-rebreather mask, OxyMask, and anesthesia mask with headstrap and Jackson Rees circuit. Since the auxiliary oxygen dial on the anesthesia machine only goes up to 10L/min, a 15L/min adjustable oxygen valve will be attached directly to the main oxygen supply line in the operating room. After placement of each mask and starting oxygen high flow, the subject will breathe normally for 90 seconds and then FiO2 will be measured over the next 30 seconds, similarly to the room air control. At the end of each trial period, each subject will be asked to take a single vital capacity breath (starting with maximum exhalation and followed by maximum inhalation). Between testing of each mask, there will be a five minute period of breathing room air as a washout period and to confirm stability of hemodynamic status (measurement of BP and HR). Demographic data to be obtained includes height (cm), weight (kg), age, gender, and self-declared ethnicity. Blood pressure, heart rate, and oxygen saturation will be recorded at baseline and prior to and following each mask-trial. Baseline FEV1/FVC measurement will be conducted on all patients prior to initiating the study and recorded. FiO2 data will be downloaded digitally from the gas analyzer to an excel spreadsheet. If this is not possible, then oxygen percentage will be manually recorded during each breath to determine the range of oxygen percentages (minimal and maximal) during both phases of ventilation, during the 30 second measurement period. Respiratory rate during measurement time will also be recorded. At the end of the 30 second sampling period, a final measurement will be taken during a forced vital capacity breath.
Data Analysis: Phase of ventilation will be defined using the capnography tracing, which is displayed concurrently with measurement of inspired oxygen. Maximal and minimal oxygen concentration will be averaged for inspiration, during the 30 second mask breathing trial, for each subject. These values will be averaged across the group for each intervention to define statistics for the entire group. Values recorded during normal tidal volume ventilation will be analyzed separately from values recorded during each forced vital capacity ventilation. The Analysis of Variance test and appropriate post-hoc analysis will be used to determine the difference between FiO2 administered by each mask tested.
Study design
- Observational model
- Case crossover
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Oxygen administration | – | Other: Oxygen administrationVia Simple Mask, Via Non-rebreather, Via OxyMask, Via Anesthesia Mask (head strap and J-R circuit), Via Room Air |
Who may qualify
- Ages
- 18 to 70 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Subjects who meet the inclusion criteria and none of the exclusion criteria who are to undergo a procedure not requiring general anesthesia.
Key inclusion criteria (4 listed)
- 18 to 70 years of age
- Male and female volunteers
- ASA physical status I, II and III
- Capable and willing to provide written informed consent in English
Key exclusion criteria (8 listed)
- Acute cardiopulmonary disease, as defined by blood pressure greater than 150/90, HR greater than 120 and room air oxygen saturation less than 92.
- Allergy to lidocaine or adhesive tape
- History or physical exam finding of nasal polyps
- Currently taking oral or parenteral anticoagulant medications (other than aspirin)
- History of frequent nose bleeds
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Oxygen administrationAlso: Simple Mask, Non-rebreather mask, OxyMaskTM, Anesthesia mask with headstrap and Jackson-Rees circuitSubjects will breathe room air for 90 seconds. FiO2 will be measured for 30 seconds. Testing of masks will be performed with oxygen set at high flow through simple mask, non-rebreather mask, OxyMaskTM, and anesthesia mask with headstrap and Jackson-Rees circuit. After placement of each mask and starting oxygen, subjects will breathe normally for 90 seconds. FiO2 will be measured for 30 seconds. After each trial, subjects will take one vital capacity breath. Between testing each mask, subjects will breathe room air for 5 minutes to confirm stability of hemodynamic status. Respiratory rate and FiO2 data will be recorded during each breath to determine oxygen percentages. At the end of the 30 second sampling period, a final measurement will be taken during a forced vital capacity breath. | Other | Oxygen administration |
Primary outcome
Oxygen Concentration Measured at the Lips by Datex-Ohmeda Differential Paramagnetic Sensor
Time frame: The subjects will each participate on one study day and will require 1 hour per subject.
After placement of each mask and starting oxygen high flow, the subject will breathe normally for 90 seconds and then FiO2 will be measured over the next 30 seconds. At the end of each trial period, each subject will be asked to take a single vital capacity breath (starting with maximum exhalation and followed by maximum inhalation). Between testing of each mask, there will be a 5 minute period of breathing room air as a washout period to confirm stability of hemodynamic status (measurement of blood pressure and heart rate).
Oxygen Concentration Measured at the Oropharyngeal Location by Nasal Catheter
Time frame: The subjects will each participate on one study day and will require 1 hour per subject.
After placement of each mask and starting oxygen high flow, the subject will breathe normally for 90 seconds and then FiO2 will be measured over the next 30 seconds. At the end of each trial period, each subject will be asked to take a single vital capacity breath (starting with maximum exhalation and followed by maximum inhalation). Between testing of each mask, there will be a 5 minute period of breathing room air as a washout period to confirm stability of hemodynamic status (measurement of blood pressure and heart rate).
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 1 Aug 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 12078655Kallstrom TJ; American Association for Respiratory Care (AARC). AARC Clinical Practice Guideline: oxygen therapy for adults in the acute care facility--2002 revision & update. Respir Care. 2002 Jun;47(6):717-20. No abstract available.
- Background: PubMed 6744963ACCP-NHLBI National Conference on Oxygen Therapy. Chest. 1984 Aug;86(2):234-47. doi: 10.1378/chest.86.2.234. No abstract available.
- Background: PubMed 22915909Paul JE, Hangan H, Hajgato J. The OxyMask() development and performance in healthy volunteers. Med Devices (Auckl). 2009;2:9-17. Epub 2008 Dec 11.
- Background: PubMed 14458557KORY RC, BERGMANN JC, SWEET RD, SMITH JR. Comparative evaluation of oxygen therapy techniques. JAMA. 1962 Mar 10;179:767-72. doi: 10.1001/jama.1962.03050100021005. No abstract available.
- Background: PubMed 15871753Wettstein RB, Shelledy DC, Peters JI. Delivered oxygen concentrations using low-flow and high-flow nasal cannulas. Respir Care. 2005 May;50(5):604-9.
- Derived from this study: PubMed 31506337Yanez ND, Fu AY, Treggiari MM, Kirsch JR. Oropharyngeal Oxygen Concentration Is Dependent on the Oxygen Mask System and Sampling Location. Respir Care. 2020 Jan;65(1):29-35. doi: 10.4187/respcare.07027. Epub 2019 Sep 10.
Related trials for Hypoxemia
Enrolling by invitation
Extubation Safety Via Microstream EtCO₂ (IPI) Monitoring
Hypoxemia
Not yet recruitingPhase 2
Supplemental Oxygen for Sleep-Disordered Breathing in Adults With Chronic Opioid Use.
Sleep-disordered Breathing, Chronic Opioid Use
RecruitingObservational study
Comparison of Pulse Oximetry (SpO2) With Different Oximeters and Arterial Saturation (SaO2): Oxygap2 Study
Respiratory Failure, Hypoxemia
Not yet recruitingObservational study
The Role of Ultrasonographic Tracheal Measurements in Predicting Hypoxemia During Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
ENDOBRONCHIAL ULTRASOUND - TRANSBRONCHIAL NEEDLE ASPIRATION, Hypoxemia
Not yet recruiting
HFNC vs Conventional Oxygen During Gastrocolonoscopy in Elderly Patients
Hypoxemia, Eldery People
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jeffrey Kirsch, MD principal investigator
Oregon Health and Science University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Hypoxemia and Trauma, run by Oregon Health and Science University at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 1 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 1 Aug 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Oxygen Concentration Measured at the Lips by Datex-Ohmeda Differential Paramagnetic Sensor (time frame: The subjects will each participate on one study day and will require 1 hour per subject.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02523586, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Aug 2018.