Knee ArthritisNCT02748096
The Assessment of Patient Specific Instrumentation for Unicompartmental Knee Replacement
A study testing Patient Specific Instrumentation and Conventional Instrumentation in people with Knee Arthritis, run by Oxford University Hospitals NHS Trust.
Trial summary
Patient-specific instrumentation guides have previously been used to improving surgical accuracy and ease of implantation during Total Knee Replacement but have received less attention for implanting Unicompartmental Knee Replacement. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Knee Arthritis
- What is being tested?
- Patient Specific Instrumentation and Conventional Instrumentation
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 45 participants
- Where
- No sites listed yet
- Study dates
- Mar 2012to Mar 2014
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Both cruciate ligaments functionally intact
- Full thickness cartilage in the lateral compartment
- Correctable intra-articular varus deformity
- Full thickness cartilage loss in the medial compartment
Who cannot join
- Contra-indication for MRI
- All forms of inflammatory arthritis
About this study
Patient-specific instrumentation guides have previously been used to improving surgical accuracy and ease of implantation during Total Knee Replacement but have received less attention for implanting Unicompartmental Knee Replacement. The aim of this prospective study is to compare the accuracy of implantation and functional outcome of mobile bearing medial Unicompartmental Knee Replacement implanted with and without patient specific instrumentation by experienced knee surgeons.
Read the detailed description
The aim of this prospective study is to compare the accuracy of implantation and functional outcome of mobile bearing medial Unicompartmental Knee Replacements implanted with and without patient specific instrumentation by experienced Unicompartmental Knee Replacement surgeons.
This single-centre parallel-design trial was conducted between March 2012 and March 2014 at the Nuffield Orthopaedic Centre, Oxford. Four expert knee surgeons performed all of the procedures in this study. Patients who were being placed on the waiting list for a medial Unicompartmental Knee Replacement, and met the entry criteria for the trial, were asked to see if they would be willing to receive further information about participation in the study. They were provided with a study information leaflet that they could read in their own time. A member of the research team subsequently contacted the patients in order to determine if they would agree to take part in the study and enrolled them onto the study.
Patients were randomized to either Patient Specific Instrumentation, or Conventional Instrumentation group. There were 23 patients (23 knees) in the Patient Specific Instrumentation group and 22 patients (22 knees) in the Conventional Instrumentation group. Randomization was performed using sealed opaque envelopes. Concealment from operating surgeons and patients was not possible owing to the surgeon needing to confirm the Patient Specific Instrumentation plans, and the patients undergoing pre-operative MRI scans. Patient Specific Instrumentation group patients underwent an MRI scan using the protocol outlined by the Patient Specific Instrumentation manufacturers to plan development of the Patient Specific Instrumentation guides. The preliminary plan indicating prosthesis size, positioning, alignment, and proposed bone resection levels was reviewed by the surgeons who accepted the default preoperative plans unless gross errors were present. The patient specific cutting blocks were then manufactured and sent for sterilization.
Operative Technique:
All patients received a mobile bearing medial Oxford unicompartmental knee replacement via a minimally invasive approach under general anaesthetic, and high thigh tourniquet. Intra-operatively, the bone cuts were made through the Patient Specific Instrumentation guides without the use of any intra or extra-medullary instrumentation on the femoral side but with a tibial extramedullary guide for some cases. The subsequent milling process and all soft tissue balancing was performed manually in the standard fashion.
Post-operatively, the need to have a blood transfusion, and the change haemoglobin levels were also recorded. Oxygen saturation levels over the first 24 hours post surgery were also recorded. Screened anteroposterior and lateral post-operative radiographs were performed prior to discharge. Patients attended the physiotherapy ward discharge clinic at six weeks. A further clinical review was performed at 12 months at which point Oxford Knee Scores were recorded.
The primary outcome measure was radiological assessment of component positioning. (See Outcome measures section for more detail)
Target sample size:
The sample size was calculated from a previous study that used similar radiological assessments to compare unicompartmental knee replacements performed using conventional instrumentation, with those performed using computer navigation. In this study, the standard deviation of the tibia varus/valgus angle for the control group was 3.6°. Assuming a minimum clinically important difference of 3°, the standard mean difference would be 0.8. Hence with a power of 0.8 and significance level of 0.05, a total sample size of 44 patients (22 in each group) was required.
- Conditions
- Knee Arthritis
- Being tested
- Patient Specific Instrumentation, Conventional Instrumentation
- Keywords
- Unicompartmental Knee Replacement, Patient Specific Instrumentation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Patient Specific InstrumentationProcedure or surgery
Patients will undergo a medial unicompartmental knee replacement. This knee replacement is implanted using patient specific cutting guides that have been produced based on the patient's individual anatomy (using plans from pre-operative MRI scans of the patient's knee).
Conventional InstrumentationProcedure or surgery
Patients will undergo a medial unicompartmental knee replacement using standard conventional instruments.
| Study group | Role | What they receive |
|---|---|---|
| Patient Specific Instrumentation | Experimental | Patients undergoing unicompartmental knee replacement with the additional aid of patient specific instrumentation. Receives: Procedure: Patient Specific Instrumentation |
| Conventional Instrumentation | Active comparator | Patients undergoing unicompartmental knee replacement using standard instrumentation. Receives: Procedure: Conventional Instrumentation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Radiological Assessment of Component Positioning
Radiological assessment of component positioning and alignment based on post-operative knee radiographs.
Measured: Within a weeks after surgery
Secondary outcomes (1)
Assessment of Functional Outcome
Use of the patient reported outcome tool (Oxford Knee Score) to determine functional outcome at one year following surgery.
Total score is 48. Minimum score 0 and Maximum score 48 with higher score indicating better function.
Scores on a scale
Measured: One year after surgery
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 Apr 2016 (estimated)
- Study startMar 2012
- Primary completionFeb 2013
- Study completionMar 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Knee ArthritisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 45 participants (actual)
Sponsor and investigators
- Lead sponsor
- Oxford University Hospitals NHS Trust
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Andrew Price, FRCS PhD, Principal investigator, Nuffield Department of Orthopaedics, Rheumatology & Musculoskeletal Sciences, University of Oxford
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02748096
- Sponsor's protocol ID
- 7110
- Status last verified
- Apr 2016
- First submitted
- 15 Apr 2016
- Last updated
- 16 Nov 2021
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- Individual data sharing
- Yes: Plan to publish in high impact peer reviewed orthopaedic journal
Study at a glance
From the registry record, last updated by the sponsor on 16 Nov 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Assessment of Patient Specific Instrumentation for Unicompartmental Knee Replacement
- ClinicalTrials.gov ID
- NCT02748096
- Acronym / sponsor ID
- 7110
- Conditions
- Knee Arthritis
- Keywords
- Unicompartmental Knee Replacement, Patient Specific Instrumentation
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 45 participants (actual)
- Lead sponsor
- Oxford University Hospitals NHS TrustUniversity, hospital or other
- Study start
- Mar 2012
- Primary completion
- Feb 2013 (actual)
- Study completion
- Mar 2014 (actual)
- First posted
- 22 Apr 2016 (estimated)
- Results
- Posted 16 Nov 2021
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Patient-specific instrumentation guides have previously been used to improving surgical accuracy and ease of implantation during Total Knee Replacement but have received less attention for implanting Unicompartmental Knee Replacement. The aim of this prospective study is to compare the accuracy of implantation and functional outcome of mobile bearing medial Unicompartmental Knee Replacement implanted with and without patient specific instrumentation by experienced knee surgeons.
Detailed description
The aim of this prospective study is to compare the accuracy of implantation and functional outcome of mobile bearing medial Unicompartmental Knee Replacements implanted with and without patient specific instrumentation by experienced Unicompartmental Knee Replacement surgeons.
This single-centre parallel-design trial was conducted between March 2012 and March 2014 at the Nuffield Orthopaedic Centre, Oxford. Four expert knee surgeons performed all of the procedures in this study. Patients who were being placed on the waiting list for a medial Unicompartmental Knee Replacement, and met the entry criteria for the trial, were asked to see if they would be willing to receive further information about participation in the study. They were provided with a study information leaflet that they could read in their own time. A member of the research team subsequently contacted the patients in order to determine if they would agree to take part in the study and enrolled them onto the study.
Patients were randomized to either Patient Specific Instrumentation, or Conventional Instrumentation group. There were 23 patients (23 knees) in the Patient Specific Instrumentation group and 22 patients (22 knees) in the Conventional Instrumentation group. Randomization was performed using sealed opaque envelopes. Concealment from operating surgeons and patients was not possible owing to the surgeon needing to confirm the Patient Specific Instrumentation plans, and the patients undergoing pre-operative MRI scans. Patient Specific Instrumentation group patients underwent an MRI scan using the protocol outlined by the Patient Specific Instrumentation manufacturers to plan development of the Patient Specific Instrumentation guides. The preliminary plan indicating prosthesis size, positioning, alignment, and proposed bone resection levels was reviewed by the surgeons who accepted the default preoperative plans unless gross errors were present. The patient specific cutting blocks were then manufactured and sent for sterilization.
Operative Technique:
All patients received a mobile bearing medial Oxford unicompartmental knee replacement via a minimally invasive approach under general anaesthetic, and high thigh tourniquet. Intra-operatively, the bone cuts were made through the Patient Specific Instrumentation guides without the use of any intra or extra-medullary instrumentation on the femoral side but with a tibial extramedullary guide for some cases. The subsequent milling process and all soft tissue balancing was performed manually in the standard fashion.
Post-operatively, the need to have a blood transfusion, and the change haemoglobin levels were also recorded. Oxygen saturation levels over the first 24 hours post surgery were also recorded. Screened anteroposterior and lateral post-operative radiographs were performed prior to discharge. Patients attended the physiotherapy ward discharge clinic at six weeks. A further clinical review was performed at 12 months at which point Oxford Knee Scores were recorded.
The primary outcome measure was radiological assessment of component positioning. (See Outcome measures section for more detail)
Target sample size:
The sample size was calculated from a previous study that used similar radiological assessments to compare unicompartmental knee replacements performed using conventional instrumentation, with those performed using computer navigation. In this study, the standard deviation of the tibia varus/valgus angle for the control group was 3.6°. Assuming a minimum clinically important difference of 3°, the standard mean difference would be 0.8. Hence with a power of 0.8 and significance level of 0.05, a total sample size of 44 patients (22 in each group) was required.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Patient Specific Instrumentation | Experimental | Procedure: Patient Specific InstrumentationPatients undergoing unicompartmental knee replacement with the additional aid of patient specific instrumentation. |
| Conventional Instrumentation | Active comparator | Procedure: Conventional InstrumentationPatients undergoing unicompartmental knee replacement using standard instrumentation. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Both cruciate ligaments functionally intact
- Full thickness cartilage in the lateral compartment
- Correctable intra-articular varus deformity
- Full thickness cartilage loss in the medial compartment
Key exclusion criteria (2 listed)
- Contra-indication for MRI
- All forms of inflammatory arthritis
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Patient Specific InstrumentationPatients will undergo a medial unicompartmental knee replacement. This knee replacement is implanted using patient specific cutting guides that have been produced based on the patient's individual anatomy (using plans from pre-operative MRI scans of the patient's knee). | Procedure or surgery | Patient Specific Instrumentation |
| Conventional InstrumentationPatients will undergo a medial unicompartmental knee replacement using standard conventional instruments. | Procedure or surgery | Conventional Instrumentation |
Primary outcome
Radiological Assessment of Component Positioning
Time frame: Within a weeks after surgery
Radiological assessment of component positioning and alignment based on post-operative knee radiographs.
1 secondary outcome
Assessment of Functional Outcome
Time frame: One year after surgery
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 16 Nov 2021.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: Yes. Plan to publish in high impact peer reviewed orthopaedic journal
Related trials for Knee Arthritis
Not yet recruiting
Holistic Healing for Knee Osteoarthritis
Knee Osteoarthritis (Knee OA)
Recruiting
Effect of Anti-inflammatory Diet in Osteoarthritis
Osteoarthritis, Knee
Active, not recruitingPhase 2/3
Single vs Triple Hyaluronic Acid in Knee Osteoarthritis
Osteoarthritis, Knee
Not yet recruiting
The Feasibility of a Virtual/Home-based OA Treatment Program in Older Adults With OA and Multimorbidity
Osteoarthritis of the Knee
RecruitingObservational study
Exploring Factors Linked to Worsening Over Time in People With Early-stage Knee Osteoarthritis and Those With Prior Proven Acute Knee Injury.
Knee Osteoarthritis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Andrew Price, FRCS PhD principal investigator
Nuffield Department of Orthopaedics, Rheumatology & Musculoskeletal Sciences, University of Oxford
Questions about this trial
What is this clinical trial studying?
A study testing Patient Specific Instrumentation and Conventional Instrumentation in people with Knee Arthritis, run by Oxford University Hospitals NHS Trust.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 16 Nov 2021. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 16 Nov 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Radiological Assessment of Component Positioning (time frame: Within a weeks after surgery). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Nov 2021.