AzTrials
AzTrials

Major Surgery Under General AnesthesiaNCT02756910

Perioperative Accuracy of the Raiing Wireless Axillary Thermometer

An observational study of Major Surgery Under General Anesthesia, run by Peking Union Medical College Hospital at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

A new wireless axillary thermometer from Raiing Medical uses a proprietary system, iThermonitor (WT701), to provide better estimates of core temperature than a conventional axillary probe. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Major Surgery Under General Anesthesia
What is being tested?
iThermonitor (WT701)
Type of treatment
Medical device
How many people
80 participants
Where
1 siteChina
Study dates
May 2016to Sep 2016
Phase
Observational

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Adult surgery patients

Who may be able to join

  • adults having an American Society of Anesthesiologists (ASA) physical status of 1-3
  • must be scheduled for surgery of the abdomen or pelvis that is expected to last 1.5-4 hours
  • require general endotracheal anesthesia and insertion of a Foley catheter

Who cannot join

  • patients in whom neither esophageal nor nasopharyngeal temperature monitoring is practical
  • patients in whom active intravenous infusion is required in both arms
  • patients who are allergic to hydrogel

Trial locations and contacts

1 site in 1 country.

China1 site
  • Dept. of Anesthesiology, PUMCH

    Beijing, 100730

Other trials in China

About this study

A new wireless axillary thermometer from Raiing Medical uses a proprietary system, iThermonitor (WT701), to provide better estimates of core temperature than a conventional axillary probe. Improvement results in part because the axillary probe measures and records temperatures continuously every 4 seconds and includes software to compensate for ambient temperature and positional changes including arm abduction.

Whether the iThermonitor is sufficiently accurate for clinical use remains unknown. The investigators thus propose to evaluate the system in perioperative patients who often experience thermal perturbations over a range of several °C. Specifically, the investigators propose to determine the precision and accuracy of iThermonitor in surgical patients and during the initial hour of recovery. As in previous studies, the investigators will consider the thermometer sufficiently accurate for clinical use if most Raiing temperatures are within ±0.5°C of the reference temperature.

Read the detailed description

Patient characteristics, including age, height, weight, sex, and ASA status, and details of the surgery, including procedure and postoperative diagnosis will be recorded. The investigator will record the time of anesthesia induction and emergence. At 10-minute intervals during surgery, the investigator will record inspired volatile anesthetic concentration, mean-arterial pressure, type of thermal management device(s), and urine output over the previous 10-minute interval.

After induction of general anesthesia (without restriction as to type), the anesthesiologist will insert a temperature sensor into the distal esophagus. The distance will be determined by maximal heart sounds (if a stethoscope is used), or the probe will be inserted 0.48.(sitting height) - 4.4 cm. If an esophageal probe cannot be used, a thermometer can be inserted to between 10 and 20 cm into the nasopharynx. The surgical team will position a Foley catheter with temperature sensor into the urinary bladder. Ambient temperature will be recorded from an electronic probe situated at the height of the patients, well away from any heat-producing equipment.

Axillary temperature will be recorded by iThermonitor, a Raiing Medical wireless module, paired to an iPhone. An adhesive patch provided by Raiing will be used to securely position the Railing probe in a shaved axilla before the anesthesia induction. Patients will be asked to adduct the ipsilateral arm for up to 5 minutes after the probe is inserted, or until the temperature displayed on the paired iPhone is stable. Thereafter, patients will be free to move their arms.Monitored arm position during surgery will be recorded (arm tightly tucked, arm loose at side, arm abducted).

Temperatures will be recorded at 10-minute intervals during surgery and during the initial postoperative hour. Just before anesthetic emergence, the esophageal or nasopharyngeal thermometer will be removed, but the Foley catheter retained. The axillary device will then be removed after an hour of recovery, and the study concluded. The Foley catheter can be removed or retained per clinical need.

Being tested
iThermonitor (WT701)
Keywords
open abdominal surgery, anesthesia, general

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • iThermonitor (WT701)Device

    Continuously monitor the axillary temperature during surgery

Study groups in NCT02756910
Study groupRoleWhat they receive
Surgery Patients >1.5 HrsUse esophageal catheter for core temperature monitoring, Foley catheter for bladder temperature monitoring, and iThermonitor (WT701) for axillary temperature monitoring
Receives: Device: iThermonitor (WT701)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of iThermonitor in Surgical Patients

    Accuracy, defined as the true difference between reference and iThermonitor temperature. The esophageal temperature will be the core temperature reference during surgery.

    The primary outcome measure is the proportion of iThermonitor measurements for a patient that are within 0.5° C of the reference will be calculated, and this proportion (median, quartiles, 95% CI) will be summarized across patients.

    The Secondary outcome measure are bias and 95% CIs determined by repeated-measures Bland-Altman analysis.

    For each patient the average difference between the iThermometer and the reference temperature will be calculated. Patient iThermonitor measurements will be regressed on patient reference measurements to assess the Pearson correlation and 95% CI between iThermonitor and reference and to estimate the bias (slope) of device versus reference.

    Measured: From 1 to 3 hours after induction of anesthesia

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Apr 2016 (estimated)
  2. Study startMay 2016
  3. Primary completionSep 2016
  4. Study completionSep 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02756910
Sponsor's protocol ID
HS-1019
Status last verified
Feb 2021
First submitted
3 Apr 2016
Last updated
14 May 2021
Data monitoring committee
No
Individual data sharing
No

Publications

  • Sessler DI. Temperature monitoring and perioperative thermoregulation. Anesthesiology. 2008 Aug;109(2):318-38. doi: 10.1097/ALN.0b013e31817f6d76.

    PubMed 18648241
  • Sessler DI. Perioperative heat balance. Anesthesiology. 2000 Feb;92(2):578-96. doi: 10.1097/00000542-200002000-00042.

    PubMed 10691247
  • Sessler DI. Complications and treatment of mild hypothermia. Anesthesiology. 2001 Aug;95(2):531-43. doi: 10.1097/00000542-200108000-00040. No abstract available.

    PubMed 11506130
  • Schmied H, Kurz A, Sessler DI, Kozek S, Reiter A. Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty. Lancet. 1996 Feb 3;347(8997):289-92. doi: 10.1016/s0140-6736(96)90466-3.

    PubMed 8569362
  • Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group. N Engl J Med. 1996 May 9;334(19):1209-15. doi: 10.1056/NEJM199605093341901.

    PubMed 8606715
  • Lenhardt R, Marker E, Goll V, Tschernich H, Kurz A, Sessler DI, Narzt E, Lackner F. Mild intraoperative hypothermia prolongs postanesthetic recovery. Anesthesiology. 1997 Dec;87(6):1318-23. doi: 10.1097/00000542-199712000-00009.

    PubMed 9416715
  • Simon HB. Hyperthermia. N Engl J Med. 1993 Aug 12;329(7):483-7. doi: 10.1056/NEJM199308123290708. No abstract available.

    PubMed 8332154
  • Sessler DI. Malignant hyperthermia. J Pediatr. 1986 Jul;109(1):9-14. doi: 10.1016/s0022-3476(86)80563-7. No abstract available.

    PubMed 3522838
  • Sessler DI. A proposal for new temperature monitoring and thermal management guidelines. Anesthesiology. 1998 Nov;89(5):1298-300. doi: 10.1097/00000542-199811000-00061. No abstract available.

    PubMed 9822041
  • Bissonnette B, Sessler DI, LaFlamme P. Intraoperative temperature monitoring sites in infants and children and the effect of inspired gas warming on esophageal temperature. Anesth Analg. 1989 Aug;69(2):192-6.

    PubMed 2764288
  • Cork RC, Vaughan RW, Humphrey LS. Precision and accuracy of intraoperative temperature monitoring. Anesth Analg. 1983 Feb;62(2):211-4.

    PubMed 6829923
  • Sessler DI. Temperature monitoring and management during neuraxial anesthesia. Anesth Analg. 1999 Feb;88(2):243-5. doi: 10.1097/00000539-199902000-00003. No abstract available.

    PubMed 9972734
  • Amoateng-Adjepong Y, Del Mundo J, Manthous CA. Accuracy of an infrared tympanic thermometer. Chest. 1999 Apr;115(4):1002-5. doi: 10.1378/chest.115.4.1002.

    PubMed 10208200
  • Suleman MI, Doufas AG, Akca O, Ducharme M, Sessler DI. Insufficiency in a new temporal-artery thermometer for adult and pediatric patients. Anesth Analg. 2002 Jul;95(1):67-71, table of contents. doi: 10.1097/00000539-200207000-00012.

    PubMed 12088945
  • Harioka T, Matsukawa T, Ozaki M, Nomura K, Sone T, Kakuyama M, Toda H. "Deep-forehead" temperature correlates well with blood temperature. Can J Anaesth. 2000 Oct;47(10):980-3. doi: 10.1007/BF03024869.

    PubMed 11032273

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in