AzTrials
AzTrials

Hearing LossNCT02772757

Coupler-Based Hearing-Aid Fitting Approach for Experienced Users

A study testing standard hearing aid fitting and coupler-based fitting in people with Hearing Loss, run by VA Office of Research and Development at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The overall aim of the study is to compare the verification accuracy and hearing-aid outcomes between the traditional, fitting approach where the patient is present during the visit and a coupler-based fitting approach where the patient is not present and mailed their hearing aids. Read more about this study

Who is it for?
Ages 18 to 85 yearsHealthy volunteers can take part
Conditions the study is for
Hearing Loss
What is being tested?
standard hearing aid fitting and coupler-based fitting
Could I receive a placebo?
No, everyone receives an active treatment
How many people
77 participants
Where
1 siteUnited States
Study dates
4 Jan 2016to 29 Dec 2017
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 85 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • no more than a moderate sensorineural hearing loss (defined as < 60 dB HL pure-tone average at 500, 1000, and 2000 Hz AU)
  • experienced BTE hearing-aid users who are obtaining replacement VA-issued BTE hearing aids coupled to a custom earmold that is simply an upgrade in model with the same style earmold
  • ability to read and write in English as determined by reading a few sentences from the consent document aloud so that self-report measures can be completed

Who cannot join

  • outer or middle ear pathology as determined by otoscopy, immittance, and/or audiometric testing (e.g., conductive or mixed losses)
  • lack of phone or non-use of the phone as the participants will be required to conduct a telephone interview after they obtain their replacement hearing aids
  • unwilling or unable to be mailed hearing aids
  • co-morbid condition that would preclude their participation as determined by a chart review

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Mountain Home VA Medical Center James H. Quillen VA Medical Center, Mountain Home, TN

    Mountain Home, Tennessee, 37684

Other trials in United States

About this study

Official title: Efficacy of a Coupler-Based Hearing-Aid Fitting Approach for Experienced Users

The overall aim of the study is to compare the verification accuracy and hearing-aid outcomes between the traditional, fitting approach where the patient is present during the visit and a coupler-based fitting approach where the patient is not present and mailed their hearing aids. If the coupler-based fitting protocol tested in this study as effective as the traditional fitting protocol, then patients receiving replacement hearing aids may circumvent a face-to-face visit.

Read the detailed description

This study will incorporate a verification technique that simulates the patient's actual ear during probe microphone verification measurements, called real-ear to coupler difference (RECD). Because the patient's ear is not used during the RECD measurement, but rather simulated, the patient would not need to be present during the RECD verification. This RECD hearing aid verification can occur in the clinic after which the hearing aids will be mailed to the patient. This study will compare the fitting accuracy and outcomes between the two approaches.

Conditions
Hearing Loss
Being tested
standard hearing aid fitting, coupler-based fitting
Keywords
hearing loss, hearing aids, outcome assessment
Medical subject headings
Hearing Loss

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • standard hearing aid fittingBehavioural

    standard hearing aid, face-to-face fitting

  • coupler-based fittingBehavioural

    coupler-based fitting using average RECDs

  • coupler-based fittingBehavioural

    coupler-based fitting using measured RECDs

Study groups in NCT02772757
Study groupRoleWhat they receive
Standard of Care groupActive comparatorStandard of Care group will receive the standard, face-to-face hearing aid fitting and verification approach
Receives: Behavioral: standard hearing aid fitting
Average RECD groupExperimentalThis group will have their hearing aid fitting via the coupler using average RECD values during the fitting
Receives: Behavioral: coupler-based fitting
Measured RECD groupExperimentalThis group will have their hearing aid fitting via the coupler using measured RECD values during the fitting
Receives: Behavioral: coupler-based fitting

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. in Situ Real-ear Aided Response (REAR)

    Deviation from prescriptive target (re: in situ REAR) from both ears of each participant for each group. This measure reflects the accuracy of the hearing aid fittings from 250 Hz through 3000 Hz (the average bandwidth of audibility).

    Measured: at the visit where in-situ real ear measurements are made (immediate post-fitting)

Secondary outcomes (3)
  1. Client-Oriented Scale of Improvement (COSI)

    The listener nominates up to five listening goals. After hearing-aid use, the listener assesses two outcomes for each goal. One outcome is the degree of change relative to the patient's unaided experience. Responses are recorded on a 5 unit categorical scale from 'worse' to 'much better'. The second outcome is the final satisfactory 'aided' ability for each goal as measured on a 5 unit categorical scale from hardy ever (10%) to almost always (95%). Higher scores reflect better outcomes for nominated goals. We calculated the percent of better and much better responses over the nominated goals and the average satisfactory aided ability over the nominated goals.

    Measured: 1 month post-fitting

  2. Device Oriented Subjective Outcome (DOSO) Scale

    The questionnaire is comprised of 28 items making up the following six subscales related to listening performance with hearing aids: (1) speech cues, (2) listening effort, (3) pleasantness, (4) quietness, (5) convenience, and (6) use. Responses from 'not at all' (1 point) to tremendously (7 points) are recorded for each item and are averaged across all items to obtain a total scale score. Higher scores reflect higher outcomes. The minimum and maximum total scores can range from 1-7 and for the three groups were: standard of care group (3.8-6.8), Average RECD group (3.3-6.7), and measured RCD group (3.8-6.5).

    Measured: 1 month post-fitting

  3. Satisfaction With Amplification in Daily Life (SADL)

    The SADL questionnaire has 15 items that examine self-reported hearing-aid satisfaction. The following four subscales are included: (1) positive effect, (2) negative features, (3) personal image, and (4) service and cost. Item 14 is omitted in populations who do not pay for hearing aids. Responses are on a 1 to 7 scale with higher numbers reflecting higher outcomes. The item responses are averaged to determine the total satisfaction score that can range from 1-7. The minimum and maximum total scores for the three groups were: standard of care group (5.1-7.0); average RECD group (4.2-6.9), and measured RECD group (4.9-7.0).

    Measured: 1 month post-fitting

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 May 2016 (estimated)
  2. Study start4 Jan 2016
  3. Primary completion1 May 2017
  4. Study completion29 Dec 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
77 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02772757
Sponsor's protocol ID
C1895-P
Status last verified
Feb 2019
First submitted
2 May 2016
Last updated
10 May 2019
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing standard hearing aid fitting and coupler-based fitting in people with Hearing Loss, run by VA Office of Research and Development at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 May 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 10 May 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

in Situ Real-ear Aided Response (REAR) (time frame: at the visit where in-situ real ear measurements are made (immediate post-fitting)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 May 2019.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in